1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the QLYUEUI SU300 series Variable Frequency Drive (VFD). Please read this manual thoroughly before using the product to ensure proper handling and to prevent potential hazards or damage.
The SU300 VFD is designed to control the speed of three-phase AC induction motors, offering precise control, energy savings, and improved system performance. This manual covers models ranging from 0.75KW to 5.5KW, with both 220V and 380V input options.
2. Safety Instructions
WARNING: Improper installation or operation can lead to serious injury or death. Only qualified personnel should install, operate, and maintain this equipment.
- Always disconnect power before performing any wiring, maintenance, or inspection. Wait at least 5 minutes after disconnecting power for capacitors to discharge.
- Ensure proper grounding of the VFD and the motor.
- Do not touch internal components or circuit boards while power is applied or immediately after power is removed.
- Install the VFD in a clean, dry, and well-ventilated environment, away from direct sunlight, corrosive gases, flammable materials, and excessive vibration.
- Verify that the input voltage matches the VFD's rated input voltage.
- Use appropriate personal protective equipment (PPE) when working with electrical equipment.
3. Product Overview
The QLYUEUI SU300 VFD features a compact design with an integrated control panel for easy operation and monitoring. Key components include the display, control buttons, and terminal blocks for power and control wiring.

3.1 Control Panel Functions
- RUN: Starts the motor.
- STOP/RESET: Stops the motor or resets fault conditions.
- PRG (Program): Enters or exits parameter setting mode.
- M-FUN (Multi-Function): Accesses multi-function parameters.
- SHIFT: Shifts digits during parameter setting or displays different parameters.
- ENTER: Confirms parameter settings.
- Up/Down Arrows: Adjusts frequency, navigates menus, or changes parameter values.
4. Specifications
The following table outlines the general specifications for the QLYUEUI SU300 series VFD. Specific parameters may vary by model variant.

| Parameter | Value |
|---|---|
| Model Series | SU300 |
| Power Range | 0.75KW - 5.5KW |
| Input Voltage Options | AC220V (1-Phase or 3-Phase), AC380V (3-Phase) |
| Output Voltage | 3-Phase, matches input voltage |
| Output Frequency Range | 0 - 400 Hz |
| Output Current (2.2KW 380V model) | 5.8A |
| General Output Current Range | 4 - 13A (varies by model) |
| Control Method | V/F Control, Vector Control |
| Protection Features | Overcurrent, Overvoltage, Undervoltage, Overheat, Overload, etc. |
| External Dimensions (2.2KW 380V model) | 142mm (H) x 85mm (W) x 116.35mm (D) |
| Gross Weight (2.2KW 380V model) | Approx. 1 kg |

5. Setup
5.1 Mounting
The VFD should be mounted vertically on a stable, non-flammable surface, ensuring adequate clearance for ventilation. Maintain sufficient space around the unit for heat dissipation and ease of access for wiring and maintenance.

5.2 Wiring
All wiring must comply with local electrical codes and regulations. Use appropriate wire gauges for power and control circuits.
5.2.1 Power Wiring
- Input Power (R, S, T or L1, L2, L3): Connect the main AC power supply to these terminals. Ensure correct phase sequence for 3-phase inputs.
- Ground (PE): Connect the protective earth ground to the designated ground terminal.
- Motor Output (U, V, W): Connect the three-phase motor leads to these terminals. Do not connect the motor's ground to these terminals.
5.2.2 Control Wiring
The VFD provides various control terminals for external control signals, such as start/stop commands, speed reference (analog input), and fault outputs. Refer to the detailed wiring diagram in the full product manual for specific terminal assignments and functions.
6. Operating Instructions
6.1 Initial Power-Up
- After completing all wiring and safety checks, apply power to the VFD.
- The display will light up, typically showing the current output frequency or a default parameter.
6.2 Basic Operation (Keypad Control)
- Set Frequency: Use the Up and Down arrow keys to adjust the desired output frequency.
- Start Motor: Press the RUN button. The motor will accelerate to the set frequency.
- Stop Motor: Press the STOP/RESET button. The motor will decelerate and stop.
6.3 Parameter Settings
The VFD has numerous parameters to configure its operation. Refer to the comprehensive parameter list in the full product manual for detailed descriptions and adjustment procedures.
- Press PRG to enter parameter setting mode.
- Use Up and Down arrows to navigate through parameter groups and individual parameters.
- Press ENTER to select a parameter and view its current value.
- Use Up and Down arrows to change the value. Use SHIFT to move between digits.
- Press ENTER to save the new value.
- Press PRG to exit parameter setting mode.
7. Maintenance
Regular maintenance ensures the longevity and reliable operation of your VFD.
- Cleaning: Periodically clean the VFD's exterior and cooling fins to prevent dust accumulation, which can hinder heat dissipation. Use a soft, dry cloth or compressed air. Ensure power is disconnected before cleaning.
- Inspection: Regularly check for loose connections, damaged wiring, or unusual noises/vibrations.
- Environment: Ensure the operating environment remains within specified temperature and humidity ranges.
8. Troubleshooting
This section provides solutions for common issues. For complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| VFD does not power on | No input power; Blown fuse; Incorrect wiring | Check power supply; Inspect fuses; Verify wiring connections. |
| Motor does not run | VFD in stop mode; Fault condition; Incorrect frequency setting; Motor wiring issue | Press RUN; Check for fault codes and reset; Adjust frequency; Verify motor wiring. |
| Overcurrent fault (OC) | Motor overload; Short circuit in motor wiring; Rapid acceleration/deceleration | Reduce motor load; Check motor and wiring for shorts; Increase acceleration/deceleration times. |
| Overvoltage fault (OV) | High input voltage; Rapid deceleration with high inertia load | Check input voltage; Increase deceleration time; Consider adding a braking resistor if applicable. |
| Undervoltage fault (UV) | Low input voltage; Momentary power loss | Check input voltage; Ensure stable power supply. |
9. Warranty and Support
For warranty information, please refer to the purchase documentation or contact your vendor. Technical support is available through the manufacturer or authorized distributors. Please have your product model and serial number ready when contacting support.
For further assistance, visit the QLYUEUI official website or contact customer service.