Aramox TM919BK

Aramox TM919BK Digital Programmable Timer User Manual

Model: TM919BK

1. Introduction

The Aramox TM919BK is a versatile digital programmable timer designed for controlling electrical appliances, such as household and garden lighting, with precision. It features 24-hour/7-day programming capabilities, allowing for up to 16 ON/OFF settings per day and 15 weekly combinations. Equipped with an LCD screen and an internal battery for program backup, this timer ensures reliable operation even during power interruptions.

Aramox TM919BK Digital Programmable Timer with clear cover open, showing the LCD display and control buttons.

Image: The Aramox TM919BK Digital Programmable Timer with its protective clear cover open, revealing the LCD screen displaying time and day, along with the red control buttons for programming.

2. Safety Information

  • Always disconnect power before installation or maintenance to prevent electric shock.
  • Installation should be performed by a qualified electrician or knowledgeable individual.
  • Ensure the timer's voltage and current ratings (85-265V AC, 30A) are compatible with your application.
  • Do not expose the device to excessive moisture or extreme temperatures outside its specified operating range (-10℃ to 50℃).
  • Keep out of reach of children.

3. Package Contents

Please check the package for the following items:

  • 1 x Aramox TM919BK Digital Programmable Timer
  • 1 x User Manual

4. Product Features

  • Programmable: 24 hours/7 days a week programming with 16 ON/OFF settings per day and 15 weekly combinations.
  • Manual Control: Ability to manually override programmed settings.
  • LCD Display: Clear LCD screen with LED indicators for easy readability.
  • DIN Rail Mount: Designed for easy installation on a 35mm DIN rail.
  • Power Backup: Built-in high-capacity battery retains programmed settings during power failures.
  • Wide Voltage Range: Operates on 85-265V AC.
  • High Capacity: Supports loads up to 30A (5000W).
  • Countdown Function: Maximum 24-hour countdown.

5. Setup and Installation

5.1. Mounting

The TM919BK timer is designed for 35mm DIN rail mounting. Securely attach the timer to the DIN rail in your electrical panel or enclosure.

Aramox TM919BK Digital Programmable Timer with clear cover closed, showing the DIN rail mounting clips.

Image: The Aramox TM919BK Digital Programmable Timer with its clear cover closed, providing a view of its compact form factor and the integrated clips for DIN rail mounting.

5.2. Wiring

Refer to the wiring diagram printed on the timer unit. Ensure all connections are secure and comply with local electrical codes.

  • Terminals 1 & 2: Power input (85-265V AC).
  • Terminals 3, 4, 5: Output contacts for the controlled device. Terminal 4 is common, Terminal 3 is normally closed (NC), and Terminal 5 is normally open (NO). Connect your load between Terminal 4 and Terminal 5 for standard ON/OFF control.

After wiring, restore power to the circuit. The timer's LCD display should illuminate.

6. Operating Instructions

Close-up of the Aramox TM919BK timer's control buttons and LCD screen.

Image: A detailed view of the Aramox TM919BK Digital Programmable Timer's front panel, highlighting the LCD display, the 'ON' indicator, and the programming buttons: P, D+, H+, M+, RESET, and MANUAL.

6.1. Initial Setup / Reset

Upon first power-up or after a long period without power, the display may be blank or show incorrect time. Press the RESET button (usually a small recessed button requiring a pointed object) to clear all settings and reset the timer to its default state. The display will show 00:00:00.

6.2. Setting the Current Time and Day

  1. Press the P button once. The display will show the current day of the week (e.g., 'Mo' for Monday).
  2. Press D+ to select the correct day of the week.
  3. Press H+ to set the current hour.
  4. Press M+ to set the current minute.
  5. Press the P button again to exit time setting mode.

6.3. Programming ON/OFF Schedules

The timer supports up to 16 ON/OFF programs. Each program consists of an ON time and an OFF time.

  1. Press the P button repeatedly until '1 ON' appears on the display. This is your first ON program.
  2. Press D+ to select the desired day(s) for this program. You can choose individual days, weekdays, weekends, or various combinations (e.g., Mo-Fr, Sa-Su, Mo-Su).
  3. Press H+ to set the ON hour.
  4. Press M+ to set the ON minute.
  5. Press the P button again. '1 OFF' will appear. This is the OFF time for your first program.
  6. Repeat steps 2-4 to set the OFF day(s), hour, and minute for '1 OFF'.
  7. Continue pressing P to cycle through '2 ON', '2 OFF', up to '16 ON', '16 OFF', setting each program as needed.
  8. After setting all desired programs, press the P button until the current time is displayed to save and exit programming mode.

6.4. Manual Override

The MANUAL button allows you to override the current program state.

  • Press MANUAL once to switch the output from AUTO to ON. The 'ON' indicator will light up.
  • Press MANUAL again to switch the output from ON to OFF. The 'OFF' indicator will light up.
  • Press MANUAL a third time to return to AUTO mode. The timer will follow its programmed schedule.

7. Maintenance

  • Cleaning: Wipe the timer with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • Battery: The internal battery is designed for long-term backup. If the timer frequently loses its settings during power outages, the battery may need replacement by a qualified technician.
  • Inspection: Periodically check wiring connections for tightness and signs of wear.

8. Troubleshooting

ProblemPossible CauseSolution
Timer display is blank.No power supply.Check power connections to terminals 1 and 2. Ensure circuit breaker is ON.
Timer does not turn ON/OFF at programmed times.Incorrect program settings. Timer is in Manual ON/OFF mode.Review program settings (time, day, ON/OFF). Press MANUAL button until 'AUTO' is displayed.
Load does not turn ON/OFF.Incorrect wiring. Faulty load.Verify wiring to terminals 3, 4, 5. Test the load directly to ensure it is functional.
Timer loses settings after power outage.Internal battery depleted or faulty.The internal battery may need replacement. Contact customer support.

9. Specifications

FeatureSpecification
ModelTM919BK
Power Supply85 ~ 265V AC
Frequency50/60Hz
Capacity30A (resistive load up to 5000W)
Time Range1 minute ~ 168 hours
Programs16 ON/OFF per day, 15 combinations per week
Power Consumption< 5VA
Average Error< 1 second/day
Temperature Range-10 ~ 50 ℃
Humidity< 95% RH
Mounting35mm DIN Rail
Dimensions (D x W x H)3.54" x 2.76" x 1.97" (90mm x 70mm x 50mm)
Item Weight147 Grams

10. Warranty and Support

For warranty information or technical support, please contact Aramox customer service through your purchase platform or the official Aramox website. Please have your model number (TM919BK) and purchase details ready when contacting support.