A-5003-0059

Instruction Manual

Dial Indicator Probe for M3 Threads

Model: A-5003-0059

1. Introduction

This manual provides essential information for the safe and effective use of the Dial Indicator Probe, Model A-5003-0059. This precision instrument is designed for accurate measurement and inspection tasks, particularly in conjunction with Coordinate Measuring Machines (CMMs) and other metrology equipment. Please read this manual thoroughly before operation to ensure proper handling, maintenance, and to prevent damage to the probe or injury to the user.

2. Safety Information

  • Always handle the probe with care to avoid dropping or impacting it, which can affect its calibration and accuracy.
  • Ensure the probe is securely mounted before use to prevent detachment during operation.
  • Do not attempt to disassemble the probe. Internal components are precisely calibrated and user disassembly will void any potential warranty and may damage the device.
  • Keep the probe clean and free from dust, debris, and corrosive substances.
  • Store the probe in its protective casing when not in use to prevent damage.

3. Product Overview

The A-5003-0059 Dial Indicator Probe is a high-precision stylus designed for accurate contact measurements. Its robust construction ensures durability and stable performance in various industrial applications.

3.1 Components and Features

  • Probe Body: Constructed from steel, providing strength and stability.
  • Ceramic Pole: Lightweight yet strong, offering built-in crash protection and suitable for non-magnetic/non-conductive environments like EDM processes.
  • Ball Head: A Ø3.0mm ball tip, typically made of ruby, known for its light weight, wear resistance, and temperature stability.
  • M3 Thread: Standard M3 thread for secure attachment to compatible CMM heads or dial indicators.
Dial Indicator Probe A-5003-0059

Figure 1: Overview of the A-5003-0059 Dial Indicator Probe.

Close-up of M3 Thread on Probe

Figure 2: Detailed view of the M3 threaded end for attachment.

Technical Drawing of Probe A-5003-0059 with Dimensions

Figure 3: Technical drawing illustrating the dimensions and materials of the probe (Unit: mm).

4. Setup

  1. Unpacking: Carefully remove the probe from its packaging. Inspect for any visible damage.
  2. Mounting:
    • Identify the M3 threaded port on your CMM head or dial indicator.
    • Gently screw the probe's M3 thread into the port.
    • Tighten securely by hand. Avoid over-tightening, which can damage the threads or the probe.
  3. Calibration (if applicable): Refer to your CMM or dial indicator's manual for specific instructions on probe calibration. Proper calibration is crucial for accurate measurements.

5. Operating Instructions

The A-5003-0059 probe is designed to be used with compatible measuring equipment. Its operation is primarily dictated by the host device (CMM, dial indicator, etc.).

  • Ensure the probe is clean before each use to prevent contamination from affecting measurements.
  • Position the probe carefully to make contact with the surface to be measured. Avoid forceful impacts.
  • Allow the probe to settle before taking a reading to ensure stability.
  • When measuring delicate surfaces, adjust the contact force settings on your measuring equipment if available.

6. Maintenance

Proper maintenance extends the life and maintains the accuracy of your probe.

  • Cleaning:
    • After each use, gently wipe the probe body and ball tip with a clean, lint-free cloth.
    • For stubborn dirt, a small amount of isopropyl alcohol can be used on the cloth. Avoid harsh chemicals or abrasive materials.
  • Storage: Store the probe in a dry, dust-free environment, preferably in its original protective case or a dedicated probe rack.
  • Inspection: Periodically inspect the ball tip for signs of wear, chipping, or contamination. A damaged tip will compromise measurement accuracy.

7. Troubleshooting

This section addresses common issues that may arise during the use of the probe.

ProblemPossible CauseSolution
Inaccurate Readings
  • Probe not calibrated.
  • Ball tip dirty or damaged.
  • Probe not securely mounted.
  • Environmental factors (temperature fluctuations).
  • Perform probe calibration according to your equipment's manual.
  • Clean the ball tip. If damaged, replace the probe.
  • Ensure the probe is tightly screwed into its port.
  • Ensure stable operating environment.
Probe Detaches During Use
  • Probe not tightened sufficiently.
  • Damaged M3 threads on probe or equipment.
  • Ensure the probe is securely hand-tightened.
  • Inspect threads for damage. If damaged, replace the affected component.

8. Specifications

ModelA-5003-0059
MaterialSteel body, Ceramic pole, Ruby ball head
ThreadM3
Ball Head DiameterØ3.0mm
Length50 mm (1.9685 inches)
Product Dimensions2.36 x 0.39 x 0.39 inches
Item Weight0.282 ounces
ManufacturerJSDZ

9. Warranty and Support

For information regarding warranty coverage, technical support, or replacement parts, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

Seller: JShomeDZ

Manufacturer: JSDZ

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.