1. Introduction
This manual provides detailed instructions for the safe and effective operation of the NYBGBAR PSG9060 60MHz Function Signal Generator. The PSG9060 is a dual-channel programmable digital frequency meter capable of generating various waveforms up to 60MHz. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.
2. Safety Information
- Always connect the device to a grounded power outlet.
- Do not operate the device in wet or damp conditions.
- Ensure proper ventilation to prevent overheating.
- Do not attempt to open or repair the device yourself. Refer all servicing to qualified personnel.
- Use only the power adapter supplied with the device.
3. Package Contents
Verify that all items are present in the package:
- 1 x NYBGBAR PSG9060 Function Signal Generator
- 1 x Power Adapter
- 1 x USB Cable (for PC connection)
- 2 x BNC to Alligator Clip Cables
- 1 x User Manual (this document)
4. Product Overview
4.1 Front Panel Layout

Figure 1: Front view of the NYBGBAR PSG9060 Function Signal Generator, showing the display, control buttons, numeric keypad, rotary encoder, and output ports.
The front panel of the PSG9060 features a clear display and intuitive controls for easy operation. Key components include:
- Display Screen: Shows waveform parameters such as frequency, amplitude, offset, and duty cycle for both channels (CH1 and CH2). The display also indicates the current waveform type (e.g., Sine).
- Control Buttons:
- SYS: System settings.
- MOD: Modulation function settings.
- MEAS: Measurement functions.
- LOAD: Load saved settings.
- SHIFT: Access secondary functions.
- SWEEP: Sweep function settings.
- FUNC: Function selection.
- Numeric Keypad (0-9, +/-): For direct entry of parameter values.
- Rotary Encoder: For fine adjustment of selected parameters.
- Output Ports (CH1 OUT, CH2 OUT): BNC connectors for signal output.
- Input Port (INPUT): BNC connector for external signal input.
5. Setup
5.1 Initial Connection
- Connect the power adapter to the DC input port on the rear panel of the PSG9060.
- Plug the power adapter into a suitable electrical outlet.
- Press the power button located on the front panel to turn on the device.
- The display will illuminate, indicating the device is ready for operation.
5.2 Connecting to a PC (Optional)
To utilize PC software for arbitrary waveform drawing or secondary development, connect the PSG9060 to your computer using the provided USB cable. Install the necessary drivers and software as instructed by the manufacturer's website.
6. Operating Instructions
6.1 Basic Waveform Generation
The PSG9060 can generate various standard waveforms including sine, square, triangle, and arbitrary waves.
- Press the FUNC button to select the desired channel (CH1 or CH2).
- Use the Wave soft key (displayed on screen) to cycle through available waveform types.
- To adjust frequency, press the Freq. soft key. Use the numeric keypad or rotary encoder to set the value.
- To adjust amplitude, press the Ampl. soft key. Use the numeric keypad or rotary encoder to set the peak-to-peak voltage (Vpp).
- To adjust DC offset, press the Offset soft key.
- To adjust duty cycle (for square waves), press the Duty soft key.
6.2 Programmable Output
The device supports programmable output, allowing you to define a sequence of waveform outputs.
- Access the programmable output settings via the SYS menu.
- Define the waveform type, output duration, and sequence for automated operation.
6.3 Firmware Update
Firmware updates can be performed to enhance functionality or address issues.
- Connect the device to a PC using the USB cable.
- Press the corresponding soft key on the device to enter update mode.
- Use the PC software to perform a one-key firmware upgrade.
6.4 Voltage-Controlled Adjustment (VCA)
The PSG9060 allows external analog voltage signals to control frequency, amplitude, and duty cycle.
- Connect an external analog voltage signal to the designated input.
- Configure the VCA settings through the device menu to enable voltage-controlled sweeping for frequency, amplitude, or duty cycle.
6.5 Modulation Function
The device supports various modulation types, which can be applied to single or dual channels.
- Press the MOD button to access modulation settings.
- Select the desired modulation type and parameters.
6.6 Dual Channel Output
The PSG9060 features two independent output channels.
- Both channels can output identical or different function signals or arbitrary waveforms.
- All parameters for each channel can be adjusted independently.
- The phase difference between CH1 and CH2 is continuously adjustable from 0 to 359.9 degrees.
6.7 Burst Function
Generate burst signals using sine, square, sawtooth, or arbitrary waveforms.
- Access the burst function settings through the menu.
- Set the number of periods for the burst, continuously adjustable between 1 and 1,000,000,000.
6.8 Pulse Width Adjustment
For pulse waveforms, the pulse width and period time can be precisely adjusted.
- Select a pulse waveform.
- Use the dedicated settings to digitally and accurately adjust the pulse width and period for jitter-free output.
6.9 Arbitrary Waveform Generation
The PSG9060 supports custom arbitrary waveforms.
- Use the provided PC software to draw and upload arbitrary waveforms to the device.
- The communication protocol is also provided for secondary development and programming.
6.10 System Color Schemes
The device offers four personalized color schemes for the system interface.
- Navigate to the system settings (SYS button).
- Use the numeric keys and rotary encoder to select your preferred color scheme.
- Press the Save soft key to apply and store the selected color.
7. Maintenance
- Keep the device clean by wiping it with a soft, dry cloth. Do not use liquid cleaners or solvents.
- Ensure all vents are clear of obstructions to maintain proper airflow.
- Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Disconnect power when the device is not in use for extended periods.
8. Troubleshooting
- No Power: Check the power adapter connection and ensure the power outlet is functional. Verify the power button is pressed.
- No Output Signal: Ensure the output channels (CH1 OUT, CH2 OUT) are enabled and connected correctly. Check frequency and amplitude settings.
- Incorrect Waveform: Verify the selected waveform type and its parameters (frequency, amplitude, offset, duty cycle).
- PC Connection Issues: Ensure the USB cable is securely connected and the correct drivers are installed on your computer.
9. Specifications
- Model: PSG9060
- Frequency Range: Up to 60MHz (for PSG9060)
- Channels: 2 independent channels
- Sampling Rate: 300MSa/s
- Vertical Resolution: 14 bits
- Output Voltage: Up to 25Vpp (within 1MHz)
- Phase Adjustment: 0 to 359.9 degrees continuous
- Programmable Output: Yes
- Modulation Function: Yes
- Burst Function: 1 to 1,000,000,000 periods
- Voltage-Controlled Adjustment: Frequency, Amplitude, Duty Cycle
- Arbitrary Waveform: Supported via PC software
- Power Source: See Details (external power adapter)
- Color: Gray
- UPC: 675580723115
10. Warranty and Support
The NYBGBAR PSG9060 Function Signal Generator comes with a standard manufacturer's warranty. For specific warranty terms, please refer to the documentation provided with your purchase or contact NYBGBAR customer support. For technical assistance, troubleshooting, or service inquiries, please visit the official NYBGBAR website or contact their customer service department.