Introduction
This manual provides essential information for the safe and effective use of your Paruu P20 Electric Breast Pump. Please read it thoroughly before first use and retain it for future reference.
The Paruu P20 is a portable, hands-free electric breast pump designed for convenience and efficiency. Its compact and lightweight design allows for discreet use anywhere, providing a comfortable and effective pumping experience for mothers.
Product Overview

Figure 1: Paruu P20 Electric Breast Pump with its components, including the pump unit, various flange sizes (19mm, 21mm, 24mm), USB charging cable, and a nipple measurement tool.

Figure 2: Overview of key features: increased pump efficiency with 12 levels, a thinner and more hidden design (61mm), 1350mAh battery for whole-day use (180min), comfortable double-layer flange, and easy cleaning with only 4 parts.
The Paruu P20 breast pump is designed for discreet and comfortable use. It features a compact and lightweight build, making it easy to wear under clothing. The transparent collector allows for visual monitoring of milk volume during pumping sessions.
Setup and Assembly
Before first use, sterilize all parts that come into contact with breast milk. The Paruu P20 is designed for easy assembly with only four main components.
- Clean and Sterilize: Wash all pump components (flange, collector, silicone diaphragm, valve) with warm soapy water and rinse thoroughly. Sterilize by boiling for 5 minutes or using a steam sterilizer. Ensure all parts are completely dry before assembly.
- Assemble the Flange and Collector: Attach the silicone flange insert (if using a smaller size) into the main flange. Then, connect the assembled flange to the milk collector cup.
- Attach the Diaphragm and Motor Unit: Place the silicone diaphragm securely onto the top of the milk collector. Ensure it forms a tight seal. Then, align the motor unit with the diaphragm and collector, pressing firmly to connect.
- Select Flange Size: Use the provided nipple measurement tool to determine the correct flange size (19mm, 21mm, or 24mm) for optimal comfort and efficiency.
- Charge the Pump: Before initial use, fully charge the pump using the provided USB cable. The LED display will indicate charging status. A full charge provides up to 180 minutes of use.

Figure 3: The four main parts of the Paruu P20 pump, highlighting its simple design for easy installation and cleaning.

Figure 4: The pump charging via USB, demonstrating its long battery life of up to 180 minutes (5-6 pumping sessions) on a single charge.
Operating Instructions
The Paruu P20 offers 4 modes and 12 suction levels for a personalized pumping experience.
- Power On: Press and hold the power button on the motor unit to turn on the pump. The LED display will illuminate.
- Select Mode: Press the 'M' button to cycle through the 4 available modes:
- Stimulation Mode: Quick and short suction to stimulate milk let-down.
- Expression Mode: Slow and long suction for efficient milk expression.
- Lactation Mode: 8 fast and 1 short pumping cycle.
- Traction Mode: Low to high suction alternation.
- Adjust Suction Level: Use the '+' and '-' buttons to adjust the suction intensity within the selected mode. There are 12 levels of suction. Start with a lower level and gradually increase to a comfortable setting.
- Monitor Progress: The smart LED display shows the current mode, suction level, and usage time. The transparent milk collector allows you to visually monitor the milk volume.
- Hands-Free Use: Once attached, the pump can be worn inside a nursing bra, allowing for hands-free operation.
- Power Off: Press and hold the power button to turn off the pump when finished.

Figure 5: Detailed view of the 4 modes (Stimulation, Expression, Lactation, Traction) and 12 suction levels, powered by an upgraded motor for extended suction range.

Figure 6: The transparent collector enables easy visualization of milk volume, and the discreet design allows for hands-free pumping while performing other tasks.

Figure 7: The Paruu P20 operates at a low noise level of approximately 50dB, ensuring it does not disturb a sleeping baby or others nearby.

Figure 8: The hands-free design allows mothers to engage in activities like playing with their baby while pumping.
Maintenance and Cleaning
Proper cleaning and maintenance are crucial for hygiene and the longevity of your breast pump.
- After Each Use: Disassemble all parts that come into contact with breast milk (flange, collector, silicone diaphragm, valve). Wash them immediately with warm soapy water. Use a soft brush to clean hard-to-reach areas. Rinse thoroughly with clean water.
- Sterilization: Sterilize these parts regularly, especially after the first use. Methods include boiling for 5 minutes, using a steam sterilizer, or a dishwasher (top rack only, if dishwasher safe). Refer to the product packaging for specific material compatibility.
- Drying: Air dry all components on a clean drying rack. Avoid using cloth towels as they may leave lint. Ensure all parts are completely dry before reassembly or storage to prevent mold and bacterial growth.
- Motor Unit: The motor unit should not be washed or submerged in water. Wipe it clean with a damp cloth if necessary.
- Storage: Store the clean and dry pump components in a clean, dry place away from direct sunlight and dust.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No suction or weak suction |
|
|
| Pump not turning on |
|
|
| Milk leaking from pump |
|
|
| Unusual noise during operation |
|
|
Specifications
- Model: P20
- Brand: Paruu
- Dimensions: 28 x 16.7 x 8.5 cm (Product); 809 g (Weight)
- Material: BPA-Free Food-Grade Silicone
- Modes: 4 (Stimulation, Expression, Lactation, Traction)
- Suction Levels: 12
- Battery: 1350 mAh
- Usage Time: Up to 180 minutes (4-5 pumping sessions) on a full charge
- Noise Level: Approximately 50dB
- Flange Sizes Included: 19mm, 21mm, 24mm
- Special Features: Portable, Hands-Free, Visual Milk Volume Display, Anti-backflow, Leak-proof design
Safety Information
- Always wash hands thoroughly before handling pump parts and breast milk.
- Do not use the pump while sleeping or overly drowsy.
- Keep the pump and all its components out of reach of children.
- Only use original Paruu replacement parts. Using unauthorized parts may void your warranty and affect pump performance.
- Do not immerse the motor unit in water or other liquids.
- If you experience pain or discomfort during pumping, stop immediately and consult a lactation consultant or healthcare professional.
- Do not use the pump if any part is damaged or broken.
Warranty and Support
While specific warranty details are not provided in this manual, Paruu products typically come with a manufacturer's warranty covering defects in materials and workmanship. Please retain your proof of purchase for warranty claims.
For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Paruu customer service through the retailer where you purchased the product or visit the official Paruu website for contact information.
Note: Warranty terms and conditions may vary by region. Please refer to the warranty card included with your product or the manufacturer's official website for the most accurate and up-to-date information.