1. Product Overview

The BLUELIZER BLT04130CC is a 4 KVA voltage stabilizer designed to protect air conditioning units up to 1.5 tons from voltage fluctuations. It features a wide input voltage range of 130-300V, an in-display ampere meter, and high/low voltage cut-off protection. This stabilizer incorporates an initial time delay system to safeguard the AC compressor and is built with full copper wiring for enhanced durability.

BLUELIZER BLT04130CC Voltage Stabilizer with key features highlighted

Image 1: The BLUELIZER BLT04130CC Voltage Stabilizer, showcasing its premium design, fire and voltage surge protection, and optimal voltage accuracy.

BLUELIZER BLT04130CC Voltage Stabilizer with advanced features

Image 2: The BLUELIZER BLT04130CC, highlighting its advanced voltage regulation, real-time ampere monitoring, and reliable protection for 1.5 Ton AC units.

2. Safety Instructions

  • Ensure the stabilizer is installed by a qualified technician.
  • Do not open the stabilizer casing; there are no user-serviceable parts inside.
  • Keep the stabilizer away from direct sunlight, moisture, and heat sources.
  • Ensure proper ventilation around the unit.
  • Verify that the input voltage range of your electrical supply is within the stabilizer's operating limits (130-300V).

3. Setup and Installation

The BLUELIZER BLT04130CC features an ergonomic wall-mounting design for easy installation. Please read this manual thoroughly before proceeding with installation.

  1. Mounting: Choose a suitable wall location near your AC unit and power outlet. Ensure the surface is sturdy enough to support the stabilizer's weight (approximately 5.6 kg). Use the provided screws and mounting template (if included) to securely attach the stabilizer to the wall.
  2. Power Connection: Connect the stabilizer's input cable to a dedicated wall power outlet.
  3. Appliance Connection: Connect your AC unit's power cord to the output socket of the stabilizer.
  4. Initial Power On: Once all connections are secure, switch on the main power supply to the stabilizer. The digital display will illuminate.

Note: For optimal performance and safety, it is recommended to have the installation performed by a certified electrician.

4. Operating Instructions

The stabilizer operates automatically to regulate voltage. Observe the digital display for operational status.

  • Initial Time Delay: Upon power-on or after a power fluctuation, the stabilizer initiates an initial time delay. This delay protects the AC compressor from frequent restarts, ensuring its longevity. The AC unit will receive power only after this delay period concludes.
  • Multifunctional Digital Display: The integrated digital display provides real-time information:
    • Input Voltage (IP): Shows the incoming voltage from the main supply.
    • Output Voltage (OP): Displays the stabilized voltage being supplied to your AC unit.
    • Load (LD) in Ampere: Indicates the current drawn by the connected AC unit in amperes.
    The display also provides warnings for high or low voltage protection events.
  • High/Low Voltage Cut-Off: The stabilizer automatically cuts off power to the AC if the input voltage goes beyond the safe operating range (below 130V or above 300V) to prevent damage. Power is restored automatically once the voltage returns to a safe level.
  • Wide Voltage Range Operation: The unit is designed to operate effectively within a broad input voltage range of 130V to 300V, ensuring consistent power supply to your appliance.
Diagram illustrating Low & High Voltage Cut, Built to Last, Microcontroller Inside, and Wide Range features

Image 3: Key features of the stabilizer, including Low & High Voltage Cut, durable construction, internal microcontroller, and wide voltage range operation.

5. Maintenance

The BLUELIZER BLT04130CC is designed for minimal maintenance. Follow these guidelines to ensure its longevity:

  • Cleaning: Periodically wipe the exterior of the stabilizer with a soft, dry cloth. Do not use liquid cleaners or solvents.
  • Ventilation: Ensure that the ventilation slots on the stabilizer are not blocked by dust or other objects. Adequate airflow is crucial for proper heat dissipation.
  • Connections: Occasionally check that all power connections are secure and free from corrosion.
  • Avoid Overloading: Do not connect appliances that exceed the stabilizer's rated capacity (4 KVA or 1.5 Ton AC).

6. Troubleshooting

If you encounter issues with your stabilizer, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Stabilizer not turning on / No displayNo power from wall outlet; Loose power connection; Stabilizer fault.Check wall outlet with another appliance. Ensure all connections are secure. If problem persists, contact support.
AC not receiving power after stabilizer turns onInitial time delay active; Input voltage out of range; Stabilizer fault.Wait for the initial time delay to complete. Check input voltage on display. If voltage is out of range, wait for it to normalize. If problem persists, contact support.
Display shows '0.0' Ampere continuously or makes humming soundNo load connected; AC unit not drawing power; Internal fault.Ensure AC unit is switched on and functioning. If the AC is on but no current is shown, or if there is an unusual humming sound, disconnect power and contact support.
Frequent high/low voltage cut-offsUnstable main power supply.This indicates the stabilizer is performing its protective function. If fluctuations are constant, consider consulting an electrician about your home's electrical supply.

If the issue is not resolved by the above steps, do not attempt to repair the unit yourself. Contact customer support.

7. Specifications

FeatureDetail
Model NumberBLT04130CC
Generic NameVOLTAGE STABILIZER
Capacity4 KVA (for up to 1.5 Ton AC)
Input Voltage Range130V - 300V
Output VoltageStabilized Output (typically 200V-240V)
FeaturesInitial Time Delay, Multifunctional Digital Display, In-Display Ampere Meter, High/Low Voltage Cut-Off, Full Copper Wired, Wall Mounted Design
Item Weight5 kg 600 g
Item Dimensions (LxWxH)15 x 10 x 10 Centimeters
Included ComponentsUser Manual, Warranty Card, Screws & Sticker

8. Warranty and Support

The BLUELIZER BLT04130CC Voltage Stabilizer comes with a 3-year replacement warranty. This warranty is subject to terms and conditions.

For warranty claims, technical support, or any inquiries, please refer to the contact information provided on the warranty card included with your product. Ensure you retain your purchase receipt for warranty validation.

Please note that unauthorized opening or tampering with the unit will void the warranty.

© 2026 BLUELIZER. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.