1. Introduction
This manual provides detailed instructions for the safe and efficient operation of your NYUMMRYT BACM2410 24V 10A Smart Float Battery Charger. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the device.
2. Safety Information
Always observe the following safety precautions to prevent injury or damage to the charger and connected equipment:
- Ensure the charger is connected to a grounded power outlet.
- Do not operate the charger in wet or damp conditions.
- Avoid short-circuiting the output terminals.
- Disconnect the AC power before making or breaking battery connections.
- Keep out of reach of children.
- Do not attempt to disassemble or repair the charger yourself. Refer to qualified service personnel.
3. Product Overview
The NYUMMRYT BACM2410 is a 24V 10A smart float battery charger designed for efficient and reliable battery charging. It features intelligent charging algorithms to optimize battery life and includes indicators for charging status.

Image 1: Front view of the NYUMMRYT BACM2410 charger. It displays input specifications (100-240VAC 4A, 50/60Hz) and output specifications (+24V 10A). The device includes AC input terminals (L, PE, N), RS485 communication terminals (A(+), B(-), MF, IN, BV, COM, BT, BLV), and battery connection terminals (B-, B+). Status indicators for 'FULL CHARGED' and 'CHARGING' are also visible.
3.1. Front Panel Layout and Indicators
- SmartGen: Brand logo.
- CE: European Conformity mark.
- INPUT: 100-240VAC 4A 50/60Hz: Specifies the acceptable AC input voltage and current.
- OUTPUT: +24V 10A: Specifies the DC output voltage and current for charging.
- FULL CHARGED Indicator: Illuminates when the connected battery is fully charged.
- CHARGING Indicator: Illuminates when the battery is actively being charged.
- BACM2410: Model number of the charger.
3.2. Connection Terminals
- L, PE, N: AC power input terminals (Live, Protective Earth, Neutral).
- RS485 (A(+), B(-), MF, IN, BV, COM, BT, BLV): Communication interface terminals for advanced monitoring or control. Refer to specific communication protocol documentation for detailed usage.
- B-, B+: DC output terminals for connecting to the battery (Negative and Positive).
4. Setup
Follow these steps for initial setup:
- Mounting: Securely mount the charger in a well-ventilated area, away from direct sunlight, heat sources, and moisture.
- AC Power Connection: Connect the AC power supply to the L, PE, and N terminals. Ensure correct polarity and a stable power source within the specified input range (100-240VAC, 50/60Hz).
- Battery Connection: Connect the battery to the B- and B+ terminals. Ensure correct polarity: B- to battery negative, B+ to battery positive.
- Optional RS485 Connection: If using the RS485 communication feature, connect the appropriate cables to the RS485 terminals as per your system requirements.
- Power On: Once all connections are secure, apply AC power to the charger.
5. Operating Instructions
The BACM2410 charger operates automatically once connected to power and a battery.
- Charging Process: Upon power-up and battery connection, the charger will automatically detect the battery status and begin the charging cycle. The 'CHARGING' indicator will illuminate.
- Float Charge: Once the battery reaches full charge, the charger will switch to float mode to maintain the battery's charge without overcharging. The 'FULL CHARGED' indicator will illuminate, and the 'CHARGING' indicator may turn off or dim depending on the specific charging stage.
- Monitoring: Regularly check the status indicators to confirm the charging process.
6. Maintenance
To ensure optimal performance and longevity of your charger:
- Keep the charger clean and free from dust and debris.
- Ensure proper ventilation around the unit.
- Periodically check all connections for tightness and corrosion.
- Do not expose the charger to extreme temperatures or humidity.
7. Troubleshooting
If you encounter issues, refer to the table below:
| Problem | Possible Cause | Solution |
|---|---|---|
| Charger not powering on | No AC input power; Loose AC connection | Check AC power source and connections (L, PE, N). |
| Battery not charging (CHARGING indicator off) | Loose battery connection; Battery deeply discharged or faulty | Check battery connections (B-, B+). Test battery condition. |
| FULL CHARGED indicator not illuminating | Battery not fully charged; Faulty battery | Allow more time for charging. Test battery condition. |
| Overheating | Poor ventilation; Overload | Ensure adequate airflow around the charger. Verify battery capacity matches charger output. |
8. Specifications
| Feature | Specification |
|---|---|
| Model | BACM2410 |
| Input Voltage | 100-240VAC |
| Input Current | 4A |
| Input Frequency | 50/60Hz |
| Output Voltage | +24VDC |
| Output Current | 10A |
| Communication Interface | RS485 |
| Package Dimensions | 1.18 x 0.79 x 0.39 inches |
| Item Weight | 1.76 ounces (50 Grams) |
| Manufacturer | NYUMMRYT |
9. Warranty Information
This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. The warranty period typically begins from the date of purchase. Please retain your proof of purchase for warranty claims. For specific warranty terms and conditions, refer to the documentation provided with your purchase or contact customer support.
10. Customer Support
For technical assistance, troubleshooting not covered in this manual, or warranty inquiries, please contact your retailer or the manufacturer directly. Please have your product model number (BACM2410) and proof of purchase ready when contacting support.