1. Introduction
The MYTREX MiRAY ONE is an advanced multi-head facial device designed for comprehensive home skincare. It integrates five distinct functions to address various skin concerns, offering a professional-grade experience. This manual provides essential information for safe and effective use of your device.

The MYTREX MiRAY ONE device, showcasing its sleek design and advanced features.
2. Safety Information
Please use the product strictly according to the prescribed procedures outlined in this manual. If any abnormalities occur during use, immediately discontinue use and contact the store of purchase or MYTREX customer support. Continuing to use the product in a faulty state may cause adverse effects on the body. Do not attempt to repair or modify the device yourself.
3. Package Contents
Verify that all items are present in the package:
- Main Unit (MYTREX MiRAY ONE) x1
- Power Cord x1
- Protective Glasses x1
- Cotton (100 sheets) x1
- Cotton Stopper x1
- Instruction Manual x1

All components included in the MYTREX MiRAY ONE package.
4. Setup
4.1 Initial Preparation
Before first use, or if the device has not been used for a long time, perform a patch test on a small, inconspicuous area of skin.
4.2 Powering On
- Connect the power cord to the device and a power outlet.
- Press and hold the power button to turn the device ON.
4.3 Attaching Cotton (for Lift Care Head)
When using the Lift Care Head, remove the cotton stopper, moisten a cotton pad with lotion or toner, and attach it to the head using the cotton stopper.

Step 1: Prepare by attaching a moistened cotton pad. Step 2: Power on the device.
5. Operating Instructions
Ensure your face is clean and free of makeup before use. Always wear the protective glasses when using the Photo Shot Head.
5.1 Photo Shot Head (DPL & NIR Modes)
The Photo Shot Head offers DPL (White Photo) and NIR (Hari Photo) modes. DPL targets melanin for transparent skin, while NIR uses thermal energy for firm skin.
- After powering on, press the power button to switch to DPL/NIR mode.
- Select your desired intensity level (Level 1-3). Beginners should start with Level 1.
- Place the head firmly against your skin and press the shot button. For continuous shots, press and hold the shot button for 3 seconds or more.
- After care, apply a sheet mask for 5-10 minutes, then moisturize thoroughly with cream.

Step 1: Power ON. Step 2: Adjust the level (1-3).

Step 3: Apply to skin and press the shot button. Step 4: Follow with moisturizing care.
5.2 Lift Care Head (EMS, Ion Moisturizer, Ion Cleansing Modes)
The Lift Care Head offers Deep EMS, Ion Moisturizer (IN mode), and Ion Cleansing (OUT mode) functions. Deep EMS contracts facial muscles for firmness, Ion Moisturizer enhances absorption of beauty ingredients, and Ion Cleansing removes impurities.
- After preparing the head with moistened cotton, press the power button to cycle through modes (EMS, OUT, IN).
- Adjust the intensity level (1-10) using the +/- buttons.
- Gently press the electrode part against your skin and move it slowly in the direction of the arrows shown in the diagram.

Select the desired mode and gently move the device across your skin as indicated.
5.3 General Product Video
This video provides a general overview of the MYTREX MiRAY ONE facial device and its features.
6. Recommended Usage Schedule
For optimal results, follow this recommended usage schedule. Adjust frequency and intensity based on your skin's condition and sensitivity.
| Care Type | Mode(s) | Duration | Focus |
|---|---|---|---|
| Daily Care 1 | IN + EMS + Moisturizing | Approx. 10 min | Moisture & Lift |
| Daily Care 2 | DPL/NIR + IN (with sheet mask) + Moisturizing | Approx. 5 min | Clarity, Firmness & Moisture |
| Daily Care 3 | DPL/NIR + Moisturizing | Approx. 4 min | Clarity & Firmness |
| Weekly Care | OUT + IN + EMS + Moisturizing | Approx. 15 min | Deep Cleansing, Moisture & Lift |
Note: For detailed instructions on each mode, please refer to the full instruction manual.

Visual guide for the recommended daily and weekly care routines.
7. Maintenance
To ensure the longevity and optimal performance of your MYTREX MiRAY ONE device, follow these maintenance guidelines:
- Always turn off the device and unplug it before cleaning.
- Wipe the device body with a soft, dry cloth.
- For the treatment heads, gently wipe with a soft cloth dampened with water or a mild, non-abrasive cleaner. Ensure no liquid enters the device.
- Do not use alcohol, thinner, or corrosive detergents, as these may damage the device.
- Store the device in a cool, dry place, away from direct sunlight and high humidity.
8. Troubleshooting
If you encounter any issues with your MYTREX MiRAY ONE, please refer to the troubleshooting section in the comprehensive instruction manual. Common issues and their solutions are typically covered there. If the problem persists, contact MYTREX customer support for assistance.
9. Specifications
| Feature | Specification |
|---|---|
| Product Size | Approx. 10.4 x 5.6 x 19.2 cm |
| Product Weight | Approx. 314 g (excluding power cord) |
| Color | White |
| Model Number | MT-MRO-24W |
| Brand | MYTREX |
| Manufacturer | SOTSU MEDICAL Co., Ltd. |
| Country of Origin | China |
| Rated Power Supply | DC24V / 2.5A |
| Power Consumption | 60W |
| AC Adapter | 100-240V 50/60Hz 1A |
| Power Cord Length | Approx. 1.5m |
| Materials | Main unit PC+ABS, silicone, aluminum alloy, glass |
10. Warranty and Support
For warranty information, product registration, and customer support, please refer to the warranty card included in your package or visit the official MYTREX website. You may also contact SOTSU MEDICAL Co., Ltd. customer service directly for any inquiries or assistance.