Introduction
This manual provides comprehensive instructions for the GIDIGI 4-in-1 Digital pH Meter, Model GX-02EU. This device is designed to accurately measure pH, Electrical Conductivity (EC), Total Dissolved Solids (TDS), and temperature in various water solutions. Please read this manual thoroughly before operation to ensure correct usage and optimal performance.
Product Features
- 4-in-1 Measurement: Simultaneously measures pH, EC, TDS (PPM), and temperature.
- Color Display: Features an updated color screen for clear and easy reading, even in low-light conditions.
- Continuous Monitoring: Designed for continuous display of pH, EC, and temperature values, particularly useful for hydroponics.
- Pre-calibrated EC/TDS: EC/TDS functions are pre-calibrated from the factory.
- Included Calibration Solutions: Comes with pH calibration powders (6 packets) and three bottles of pH calibration solution (4.00pH, 7.00pH, 10.01pH) for immediate use.
- Power Supply: Operates on AAA batteries (4 included, 4 spare).
Package Contents
- GIDIGI 4-in-1 Digital pH Meter (Model GX-02EU)
- AAA Batteries (4 installed, 4 spare)
- pH Calibration Powders (6 packets)
- pH Buffer Solutions (3 bottles: 4.00pH, 7.00pH, 10.01pH)
- User Manual (this document)

Product Overview
The GIDIGI 4-in-1 Digital pH Meter features a robust design with an integrated probe and a clear color display. Key components include:
- Display Screen: Shows pH, EC/TDS (PPM), and temperature readings.
- ON/OFF/RESET Button: Powers the device on or off, and resets settings.
- MODE/CAL Button: Switches between measurement modes (e.g., EC/TDS) and initiates calibration.
- HOLD/TEMP Button: Freezes the current reading on the display or switches temperature units.
- Probe: The sensing element for water quality measurements.
- Battery Compartment: Located at the top, houses AAA batteries.

Setup
- Battery Installation: The device comes with 4 AAA batteries pre-installed. If replacement is needed, open the battery compartment at the top and insert 4 new AAA batteries, observing polarity.
- Initial Power On: Press the "ON/OFF/RESET" button to power on the device. The color display will illuminate.
- Rinse Probe: Before first use and after each use, rinse the probe with distilled water and gently blot dry with a clean tissue. Do not rub the probe.
Calibration
pH Calibration
Accurate pH measurement requires regular calibration. The device supports 3-point calibration (4.00pH, 7.00pH, 10.01pH).
- Prepare Solutions: Use the provided pH buffer solutions (4.00pH, 7.00pH, 10.01pH). Ensure they are at room temperature.
- Clean Probe: Rinse the probe with distilled water and dry it.
- Start Calibration: Power on the meter. Press and hold the "MODE/CAL" button until "CAL" appears on the display.
- Calibrate 7.00pH: Immerse the probe into the 7.00pH buffer solution. The meter will automatically recognize the solution and calibrate. Wait for the reading to stabilize and for the calibration indicator to confirm.
- Calibrate 4.00pH: Rinse the probe with distilled water and dry it. Immerse the probe into the 4.00pH buffer solution. The meter will automatically recognize and calibrate.
- Calibrate 10.01pH (Optional): Rinse the probe with distilled water and dry it. Immerse the probe into the 10.01pH buffer solution. The meter will automatically recognize and calibrate.
- Finish Calibration: Once all desired points are calibrated, the meter will return to measurement mode.
Note: The included pH calibration powders can be used to prepare fresh buffer solutions if needed. Follow the instructions on the powder packets for preparation.
EC/TDS Calibration
The EC/TDS functions are pre-calibrated by the manufacturer and generally do not require user calibration. If you suspect inaccuracies, contact customer support.
Operating Instructions
- Power On: Press the "ON/OFF/RESET" button to turn on the meter.
- Rinse Probe: Rinse the probe with distilled water and gently dry it.
- Immerse Probe: Dip the probe into the water solution you wish to test. Ensure the probe is fully submerged but do not submerge the entire meter.
- Read Measurements: The display will show pH, EC/TDS (PPM), and temperature readings simultaneously. Allow a few seconds for the readings to stabilize.
- Switch Modes (EC/TDS): If the display shows EC and you prefer TDS (PPM), or vice-versa, briefly press the "MODE/CAL" button to toggle between them.
- Hold Reading: To freeze the current reading on the display, press the "HOLD/TEMP" button. Press it again to release.
- Change Temperature Unit: While in measurement mode, press and hold the "HOLD/TEMP" button to switch between Celsius (°C) and Fahrenheit (°F).
- Power Off: After use, rinse the probe, dry it, and press the "ON/OFF/RESET" button to turn off the meter.
Maintenance
- Cleaning the Probe: Always rinse the probe with distilled water after each use to prevent contamination and ensure accurate readings. Gently blot dry; do not wipe vigorously.
- Storage: Store the meter in a cool, dry place. Ensure the probe is clean and dry before storage. For prolonged storage, it is recommended to keep the pH electrode moist by storing it in a small amount of pH storage solution or 7.00pH buffer solution. Do not store dry.
- Battery Replacement: Replace AAA batteries when the low battery indicator appears on the display.
- Calibration: Calibrate the pH function regularly, especially if readings become inconsistent or after prolonged storage.
Troubleshooting
- Inaccurate Readings:
- Ensure the probe is clean.
- Recalibrate the pH function.
- Check battery level.
- Ensure the probe is fully submerged in the sample.
- Display Not Working:
- Check battery installation and replace if necessary.
- Press the "ON/OFF/RESET" button firmly.
- "CAL" Error During Calibration:
- Ensure the correct buffer solution is used for the calibration point.
- Verify buffer solutions are not expired or contaminated.
- Clean the probe thoroughly.
Specifications
| Parameter | Value |
|---|---|
| Model Number | GX-02EU |
| Measurement Parameters | pH, EC, TDS (PPM), Temperature |
| Power Source | 4 x AAA Batteries (included) |
| Product Dimensions | 4.6 x 3.19 x 21.8 cm |
| Weight | 590 g |
| Manufacturer | Jinan jixin dianzi youxiangongsi |
Applications
The GIDIGI 4-in-1 Digital pH Meter is suitable for a wide range of applications, including but not limited to:
- Hydroponic solutions
- Swimming pools and spas
- Aquariums and aquaculture
- Pond water
- Drinking water and tap water
- Brewing (craft beer, kombucha)
- Fermentation processes
- Rainwater and spring water

Support and Warranty
For any questions regarding the GIDIGI 4-in-1 Digital pH Meter, the GIDIGI team is available online 24 hours a day. Please do not hesitate to contact us for assistance. We are committed to helping you resolve any issues within 24 hours.
All accessories compatible with this pH meter, including pH-EC calibration pads and replacement probes, can be found in the GIDIGI Store.
While specific warranty details are not explicitly provided, GIDIGI emphasizes customer satisfaction and support for their products.
Related Documents - GX-02EU
![]() |
E-1 Portable TDS & EC Meter and pH Meter User Manual Comprehensive user manual for the E-1 Portable TDS & EC Meter and pH Meter, detailing product specifications, operation, calibration, maintenance, and troubleshooting for accurate water quality testing. |
![]() |
Konvio Neer TDS Meter User Guide and Specifications A concise guide to using the Konvio Neer TDS Meter for measuring water quality in PPM, including instructions, specifications, and customer support information. |
![]() |
Divolight 4-in-1 Water Quality Tester: User Manual and Calibration Guide This guide provides instructions for operating and calibrating the Divolight 4-in-1 Water Quality Tester (Model DVL05-150-S-W-4F01), which measures pH, EC, TDS, and temperature. Learn about its features, specifications, and usage steps. |
![]() |
JUANJUAN Water Quality Meter User Manual: Operation, Precautions, and Troubleshooting Comprehensive user manual for the JUANJUAN Water Quality Meter, detailing product overview, usage methods, essential precautions, and troubleshooting tips for accurate water quality testing. |
![]() |
TDS Water Quality Tester User Manual User instructions for the TDS/EC/Temperature water quality tester, covering power on, testing procedures, data hold, and storage maintenance. |
![]() |
WATRIUS E-2 TDS & EC Tester Kasutusjuhend Kaasaskantav WATRIUS E-2 TDS & EC tester veekvaliteedi mõõtmiseks. Juhend TDS-i, EC ja temperatuuri mõõtmiseks, funktsioonideks, hoolduseks ja ohutuks kasutamiseks. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.