1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your X X-HOUSE C01-L Automatic Dual Swing Gate Opener. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.
2. Safety Information
- Ensure all electrical connections are performed by a qualified professional and comply with local electrical codes.
- Disconnect power to the gate opener before performing any maintenance or repairs.
- Keep children and pets away from the gate area during operation.
- Do not attempt to stop a moving gate.
- Regularly inspect the gate and opener for signs of wear, damage, or misalignment.
- The manual release key should be accessible for emergency situations.
3. Package Contents
Verify that all components listed below are included in your package:
- Swing Gate Openers (Actuators) x 2
- 12V 20W Solar Panel x 1
- 12V Batteries x 2 (for parallel connection)
- Remote Control x 2
- Control Box (with control board and battery compartment) x 1
- Installation Accessories (brackets, bolts, pins, etc.) x 1 set
- Detailed Installation Instructions (User Manual) x 1

Figure 3.1: Complete X X-HOUSE C01-L Gate Opener Kit Components

Figure 3.2: Detailed view of included components and accessories.
4. Specifications
| Feature | Specification |
|---|---|
| Model Number | PKM-C01-L |
| Max Gate Weight (per leaf) | 330 lbs (150 KG) |
| Max Gate Length (per leaf) | 8 ft (2.4 M) |
| Motor Voltage | 12V DC |
| Motor Power | 40W |
| Solar Panel | 12V 20W (Included) |
| Batteries | 2 x 12V Lead Acid (Included, parallel connection) |
| Remote Control Range | Up to 100 ft |
| Max Remotes Supported | 120 |
| Material | Aluminum |
| Product Dimensions | 30 x 2.5 x 2.5 inches (Actuator) |
| Item Weight | 47 pounds (Total Kit) |

Figure 4.1: Motor specifications and features.
5. Setup and Installation
Follow the detailed instructions provided in the included installation manual for precise setup. Key considerations include:
5.1 Power Supply Options
The gate opener supports multiple power configurations:
- AC Electric Only: Connect a 12V AC power source to the AC power port. A transformer is not included.
- Solar Panel and Backup Batteries (Recommended): Use the included 12V 20W solar panel and two 12V batteries (connected in parallel) as the primary power source. Ensure batteries are fully charged before first use.
- AC Electric, Solar Panel, and Batteries: Combine AC power with the solar panel and batteries for continuous operation and backup. A transformer is not included.

Figure 5.1: Solar System Kit Wiring Diagram

Figure 5.2: Multiple Power Supply Options
5.2 Gate Configuration
The opener supports both push-to-open and pull-to-open gate configurations. Ensure the motor wiring is correctly reversed if using a push-to-open setup.

Figure 5.3: Gate Installation Methods and Capacity

Figure 5.4: Installation Modes and Features
6. Operating Instructions
6.1 Remote Control Operation
The system includes two remote controls with a maximum operating distance of 100 feet. Up to 120 remotes can be programmed. Refer to the detailed installation manual for remote programming instructions.

Figure 6.1: Remote Control Usage
6.2 Auto-Close Function
The control board features an auto-close function for convenience and security. This can be configured to automatically close the gate after a set period. Consult the detailed manual for adjustment procedures.
6.3 Safety Stop-and-Reverse
The system is equipped with a safety stop-and-reverse feature. If an obstruction is detected during gate opening or closing, the gate will stop and reverse direction to prevent injury or damage.

Figure 6.2: Advanced Obstacle Detection
6.4 Manual Release
In case of power failure or system malfunction, use the included manual release key to disengage the gate opener and operate the gate manually.
7. Maintenance
- Regular Inspection: Periodically check all mounting hardware, gate hinges, and moving parts for tightness and wear.
- Cleaning: Keep the gate opener arms and solar panel clean from dirt, debris, and snow to ensure optimal performance.
- Battery Check: If using solar power, ensure the batteries are holding a charge. Replace batteries as needed.
- Lubrication: Apply appropriate lubricant to moving parts as recommended in the detailed installation manual.
8. Troubleshooting
If you encounter issues with your gate opener, consider the following general troubleshooting steps:
- Gate not responding to remote: Check battery in remote. Ensure power is supplied to the control board. Reprogram remotes if necessary.
- Gate operates intermittently: Check battery charge level, especially for solar-powered setups. Ensure solar panel is clean and receiving adequate sunlight.
- Gate stops unexpectedly: Check for obstructions in the gate's path. Inspect wiring connections for looseness or damage.
- Gate not opening/closing fully: Verify limit switch settings. Check for mechanical binding or obstruction in the gate's movement.
For more specific troubleshooting or persistent issues, refer to the detailed installation manual or contact customer support.
9. Warranty and Support
X-XHOUSE is committed to providing high-quality, reliable products and professional after-sales service. All products come with a one-year warranty.
For any problems or inquiries, please contact our 24-hour after-sales service:
Service Email: smart02@x-house.net
Our professional team is ready to provide satisfactory solutions for any issues you encounter.