FOLIAGE 17AIEAC2010 (2021), 17RIEAC2010 (2021)
FOLIAGE 6 Terminal Ignition Switch User Manual
For Cub Cadet Models 17AIEAC2010 (2021) and 17RIEAC2010 (2021)
Product Overview
This manual provides essential information for the FOLIAGE 6 Terminal Ignition Switch, designed as a direct replacement part for Cub Cadet models 17AIEAC2010 (2021) and 17RIEAC2010 (2021). This switch is crucial for the proper starting and operation of your equipment's engine.

Image: Front view of the FOLIAGE 6 Terminal Ignition Switch, showing the keyhole and terminal configuration.
Key Features
- Compatibility: Specifically designed for Cub Cadet 17AIEAC2010 (2021) and 17RIEAC2010 (2021) models.
- Functionality: Ensures proper starting and stopping of the engine.
- Reliability: Provides reliable performance and durability.
- Quality: A replacement part engineered to enhance tool performance.
- Terminals: Features a 6-terminal design for secure electrical connections.
Setup and Installation
Before beginning installation, ensure the equipment is turned off and the battery is disconnected to prevent electrical shock or damage. Refer to your Cub Cadet equipment's service manual for specific instructions on accessing and replacing the ignition switch.
- Safety First: Disconnect the negative battery cable from your Cub Cadet equipment.
- Locate Old Switch: Identify the existing ignition switch on your equipment.
- Disconnect Wiring: Carefully disconnect all wires from the old ignition switch. Note the position of each wire, or take a photograph for reference.
- Remove Old Switch: Remove any retaining nuts or clips securing the old switch and carefully pull it out.
- Install New Switch: Insert the FOLIAGE 6 Terminal Ignition Switch into the opening.
- Connect Wiring: Reconnect the wires to the new switch, ensuring each wire is attached to its correct terminal. The 6-terminal design requires precise connection.
- Secure Switch: Secure the new switch with its retaining nut or clips.
- Reconnect Battery: Reconnect the negative battery cable.
- Test Functionality: Test the ignition switch to ensure proper operation before using the equipment.

Image: Rear view of the ignition switch, illustrating the 6 terminal connections for wiring.
Operating Instructions
Once installed, the FOLIAGE 6 Terminal Ignition Switch operates identically to the original equipment manufacturer (OEM) switch. Insert the key and turn it to the desired position (e.g., OFF, RUN, START) to control the equipment's electrical system and engine.
- OFF: Engine and electrical system are off. Key can be removed.
- RUN: Engine is running or ready to run. Electrical accessories may be powered.
- START: Engages the starter motor to crank the engine. Release key once engine starts.
Maintenance
The FOLIAGE 6 Terminal Ignition Switch is designed for durability and typically requires minimal maintenance. However, regular inspection can prolong its lifespan and ensure reliable operation.
- Periodic Inspection: Annually inspect the switch and its wiring for any signs of wear, corrosion, or loose connections.
- Cleaning: Keep the area around the switch clean and free of debris, dirt, or moisture. Use a dry cloth for cleaning.
- Avoid Force: Do not force the key into the switch or apply excessive force when turning it.
Troubleshooting
If you experience issues with your equipment's ignition, consider the following common troubleshooting steps related to the ignition switch:
| Problem | Possible Cause | Solution |
|---|---|---|
| Engine does not crank when key is turned to START. | Loose or corroded battery terminals; faulty battery; wiring issue; faulty starter motor; faulty ignition switch. | Check battery connections and charge; inspect wiring for damage; test starter motor; verify ignition switch connections. |
| Engine cranks but does not start. | No fuel; spark plug issues; carburetor issues; ignition system fault (not necessarily switch). | Check fuel level; inspect spark plugs; consult equipment manual for engine-specific troubleshooting. |
| Key is difficult to turn or remove. | Debris in keyhole; worn key; internal switch mechanism issue. | Clean keyhole; try a spare key; if issue persists, switch may need replacement. |
If troubleshooting steps do not resolve the issue, it is recommended to consult a qualified service technician or refer to your Cub Cadet equipment's comprehensive service manual.
Specifications
- Product Type: Ignition Switch
- Terminals: 6
- Compatibility: Cub Cadet 17AIEAC2010 (2021), 17RIEAC2010 (2021)
- Brand: FOLIAGE
- ASIN: B0DPJDW318
- UPC: 670094085100
- Manufacturer: FOLIAGE
- Date First Available: December 3, 2024
Please review the product dimensions and carefully check the photos provided to ensure the right fit for your equipment.
Warranty and Support
For specific warranty information regarding your FOLIAGE 6 Terminal Ignition Switch, please refer to the documentation included with your purchase or contact FOLIAGE customer support directly. As a replacement part, its warranty may be subject to the terms and conditions of the original equipment manufacturer or the retailer from whom it was purchased.
For technical support or inquiries, please reach out to the FOLIAGE customer service team. Contact details are typically available on the product packaging or the official FOLIAGE website.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.