QIQIBABA 1006801R

1006801R Control Board Instruction Manual

Model: 1006801R | Brand: QIQIBABA

Introduction

This manual provides essential information for the installation, operation, and maintenance of the QIQIBABA 1006801R Control Board. This printed circuit board is designed as a direct replacement for electric furnaces in the E7 and B6 series, specifically for single-stage electric heat systems. Proper installation and adherence to safety guidelines are crucial for optimal performance and safety.

QIQIBABA 1006801R Control Board

Figure 1: Overview of the 1006801R Control Board.

Safety Information

Always prioritize safety when working with electrical components and heating systems. Failure to follow these safety instructions could result in property damage, serious injury, or death.

Compatibility

The 1006801R Control Board is designed for specific furnace and air handler models. Verify your existing unit's model number against the lists below to ensure compatibility.

For E7 Series Furnace Models:

This single-stage circuit board fits furnace & air handler models E7 and FSHE. Compatible with models ending in -010, -012, -015, -017, -020, -023.

Compatibility chart for E7 and B6 series furnaces

Figure 2: Detailed compatibility for E7 and B6 series models.

For B6 Series Furnace Models:

Also suitable for the following B6 Series Air Handlers:

Note: For B6BMMX Series Air Handler, use on units produced on or before 12/31/2017.

Setup and Installation

The installation of a furnace control board requires careful attention to detail and electrical safety. It is highly recommended that this procedure be performed by a certified HVAC technician.

  1. Power Disconnection: Turn off all electrical power to the furnace unit at the main service panel. Confirm power is off using a non-contact voltage tester.
  2. Access the Control Board: Locate and open the furnace access panel to expose the existing control board.
  3. Document Wiring: Before disconnecting any wires, take clear photographs of the existing wiring connections. Label each wire and its corresponding terminal on the old board. This step is critical for correct re-installation.
  4. Disconnect Wires: Carefully disconnect all wires from the old control board.
  5. Remove Old Board: Unmount the old control board from its housing. Note how it was secured (screws, clips, etc.).
  6. Install New Board: Mount the new 1006801R Control Board in the same position as the old one. Ensure it is securely fastened.
  7. Connect Wiring: Refer to your photographs and labels to connect each wire to its correct terminal on the new board. Double-check all connections for tightness and accuracy.
  8. Close Access Panel: Once all connections are secure and verified, close and secure the furnace access panel.
  9. Restore Power: Turn on the electrical power to the furnace unit at the main service panel.
  10. Test Operation: Initiate a heating cycle to verify that the furnace operates correctly and the new control board is functioning as expected. Listen for unusual noises and observe the furnace's behavior.
Close-up view of the 1006801R Control Board components

Figure 3: Detailed view of the control board, showing various connectors and components.

Operating Principles

The 1006801R Control Board is designed to manage the operations of single-stage electric furnaces and air handlers. It acts as the central processing unit, receiving signals from the thermostat and other sensors to control the heating elements, blower motor, and other furnace functions.

Maintenance

The 1006801R Control Board itself requires no routine maintenance. However, regular maintenance of your furnace system is essential for its longevity and efficient operation.

Troubleshooting

If your furnace is not operating correctly after installing the 1006801R Control Board, consider the following common troubleshooting steps. For complex issues, consult a qualified technician.

ProblemPossible CauseSolution
Furnace not turning onNo power to the unit; thermostat setting incorrect; loose wiring connection; tripped circuit breaker.Check circuit breaker; ensure thermostat is set to heat and fan is on auto; verify all wiring connections on the control board are secure.
Blower not operatingBlower motor issue; control board fault; thermostat fan setting.Check thermostat fan setting (try "On" instead of "Auto"); inspect blower motor for obstructions; if problem persists, professional diagnosis is needed.
Furnace cycles on and off rapidly (short cycling)Restricted airflow (dirty filter); overheating; faulty sensor.Replace air filter; ensure vents are open; check for obstructions around the furnace. If the issue continues, a technician should inspect for overheating or sensor problems.
Diagnostic LED codes on boardIndicates a specific system fault.Refer to your furnace's original manual for the interpretation of specific LED flash codes. These codes pinpoint the exact issue.

Specifications

FeatureDetail
Model Number1006801R
ManufacturerQIQIBABA
Item Weight10.8 ounces
Product Dimensions5.9 x 7.4 x 1.57 inches
Included Components1006801R Control Board
CompatibilityE7 & B6 Series Electric Furnaces (Single Stage Electric Heat)
Replaces OE Part #1006801R, 1006800/1
1006801R Control Board compatible with various electric furnace power ratings

Figure 4: The 1006801R Control Board is compatible with 12kW, 15kW, 17kW, 20kW, and 23kW electric furnaces.

Warranty and Support

The QIQIBABA 1006801R Control Board comes with a warranty to ensure customer satisfaction.

Related Documents - 1006801R

Preview Partners Choice E7 Series Electric Furnace Replacement Parts List
Comprehensive replacement parts list for Partners Choice E7 Series electric furnaces, including model numbers and part numbers for components like blower housing, motors, circuit breakers, and doors. Nortek Global HVAC LLC.