1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your LUTRZPVT TM928-10A Programmable Electronic Time Clock. Please read this manual thoroughly before using the device to ensure safe and efficient operation. Keep this manual for future reference.
2. Safety Information
- Ensure the power supply is disconnected before installation or maintenance to prevent electric shock.
- Installation should be performed by a qualified electrician or knowledgeable individual.
- Do not exceed the specified load capacity (10A for TM928-10A).
- Do not expose the device to moisture, extreme temperatures, or corrosive environments.
- Verify correct wiring connections before applying power.
3. Product Overview
3.1 Features
- Digital clock display with backlight.
- 7-day programmable timer with up to 8 ON/OFF programs.
- Setting range from 1 second to 168 hours.
- Lock function to prevent accidental changes.
- Compact 35mm DIN rail installation.
3.2 Components and Display
The LUTRZPVT TM928-10A features a clear LCD backlight display and intuitive control buttons.

Figure 1: Front view of the TM928-10A timer, showing the LCD display with current time (9:28:59) and day (Sunday), along with control buttons (MENU, Res, OK, Up, Down).

Figure 2: The TM928-10A timer with its clear protective cover closed, providing protection for the display and buttons.

Figure 3: The TM928-10A timer with the clear protective cover open, allowing access to the control buttons for programming and settings adjustments.
4. Setup and Installation
4.1 Mounting
The TM928-10A is designed for 35mm DIN rail installation. Securely attach the device to a standard DIN rail in an appropriate electrical enclosure.

Figure 4: Bottom view of the TM928-10A, highlighting the orange DIN rail mounting clip for easy installation onto a standard 35mm DIN rail.
4.2 Wiring
Refer to the wiring diagram below for proper connection. Ensure all connections are tight and secure.

Figure 5: Wiring diagram for the TM928-10A, showing input (IN) terminals for Neutral (N) and Live (L), and output (LOAD) terminals for Neutral (N) and Live (L). The input voltage range is 85-265V AC.
- Connect the incoming Live (L) and Neutral (N) wires to the "IN" terminals.
- Connect the load's Live (L) and Neutral (N) wires to the "LOAD" terminals.
- Ensure the voltage (110V or 220V) matches the device's operating range (85-265V).
5. Operating Instructions
5.1 Initial Power-Up and Reset
Upon first power-up or after a power outage, the display may be blank or show incorrect time. Press the Res button (Reset) to clear all settings and initialize the device. The display will show 0:00 and the current day.
5.2 Setting Current Time and Day
- Press and hold the MENU button for approximately 3 seconds until the hour digit flashes.
- Use the Up (▲) and Down (▼) buttons to adjust the hour.
- Press MENU again to move to the minute setting. Adjust with Up and Down.
- Press MENU again to move to the day setting. Adjust with Up and Down (e.g., Mo, Tu, We, Th, Fr, Sa, Su).
- Press OK to save the settings and exit.
5.3 Programming ON/OFF Cycles
The TM928-10A supports up to 8 ON/OFF programs. Each program consists of an ON time and an OFF time.
- Press the MENU button once to enter program setting mode. The display will show "1 ON".
- Use Up and Down to select the desired day(s) for this program (e.g., Mo-Su, Mo-Fr, Sa-Su, individual days).
- Press MENU to set the ON hour, then MENU for ON minute. Adjust with Up and Down.
- Press MENU again. The display will show "1 OFF".
- Repeat the steps to set the OFF hour and OFF minute for the same program.
- Press MENU to advance to the next program ("2 ON") or OK to save and exit.
- Repeat for up to 8 programs. If fewer than 8 programs are needed, press OK to exit after setting your last program.
5.4 Manual Override / AUTO ON/OFF
The timer typically operates in "AUTO ON" or "AUTO OFF" mode, following the programmed schedule. You can manually override the current state:
- Press the OK button (when not in programming mode) to cycle through modes: AUTO ON → ON → AUTO OFF → OFF.
- In ON mode, the output is continuously ON, ignoring programs.
- In OFF mode, the output is continuously OFF, ignoring programs.
- Return to AUTO ON or AUTO OFF for programmed operation.
5.5 Lock Function
To prevent accidental changes to settings, the device features a lock function.
- To lock the device: Press and hold the Down (▼) button for approximately 5 seconds until "LOCK" appears on the display.
- To unlock the device: Press and hold the Down (▼) button for approximately 5 seconds until "LOCK" disappears.
6. Maintenance
- Clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Ensure proper ventilation around the device.
- No user-serviceable parts inside. Do not attempt to open the casing.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is blank. | No power supply. | Check power connections and circuit breaker. |
| Timer not switching ON/OFF as programmed. | Incorrect program settings; Manual override active; Device in OFF mode. | Verify program settings. Ensure the device is in "AUTO ON" or "AUTO OFF" mode. |
| Buttons are unresponsive. | Lock function is active. | Unlock the device by holding the Down button for 5 seconds. |
| Time is incorrect after power outage. | Internal battery depleted or not present (for backup). | Reset the time and day. The device has a backup battery for settings, but not for clock accuracy during extended power loss. |
8. Specifications
| Model Number | TM928-10A |
| Power Supply | 85~265V AC, 50/60Hz |
| Load Capacity | 10A |
| Programs | 8 ON/OFF cycles per day/week |
| Setting Range | 1 second to 168 hours |
| Setting Interval | 1 second |
| Display | LCD with backlight |
| Dimensions | 86 x 65 x 36mm |
| Installation | 35mm DIN rail |
9. Warranty and Support
Specific warranty information for the LUTRZPVT TM928-10A Programmable Electronic Time Clock is not provided in this document. For warranty details, technical support, or service inquiries, please contact your retailer or the manufacturer directly.
Manufacturer: LUTRZPVT