Sunmerit JF068+53T+R28

Sunmerit Universal Ceiling Fan Remote Control Switch Kit

Model: JF068+53T+R28

Brand: Sunmerit

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Sunmerit Universal Ceiling Fan Remote Control Switch Kit. This kit is designed to provide convenient control over your ceiling fan's speed and light functions, including dimming, from both a wall-mounted switch and a handheld remote. It features an upgraded 3-wire connection for simplified installation.

2. Safety Information

  • Always turn off power at the circuit breaker before beginning installation or performing any maintenance.
  • Installation should be performed by a qualified electrician if you are not comfortable with electrical wiring.
  • Ensure all wiring connections are secure and properly insulated.
  • This device is for indoor use only.
  • Do not exceed the maximum load ratings for the fan and light.

3. What's in the Box

  • 1 x Receiver
  • 1 x Wall Switch
  • 1 x Remote Control (requires 9V battery, not included)

4. Setup and Installation

4.1 Wiring Diagram

This upgraded kit requires only 3 wires from the wall switch to control the ceiling fan and lights (AC Load IN, AC Load OUT, and Ground line). Refer to the diagram below for proper wiring connections.

Wiring diagram for Sunmerit ceiling fan remote control kit showing connections for AC IN L, AC IN N, OUT L, To Light L, To Motor L, To Motor N, and Ground.

Figure 1: Wiring Diagram for Receiver and Wall Switch

4.2 DIP Switch Setting

To ensure proper communication between the remote, wall switch, and receiver, the DIP switch settings on all three components must match. The kit offers 16 different code frequencies to prevent interference with other devices. The factory setting is typically all 'up' (ON), but you can adjust these as needed.

Close-up of DIP switches on the receiver, remote, and wall switch, showing positions 1, 2, 3, 4.

Figure 2: DIP Switch Locations and Settings

4.3 Compatibility

This kit is compatible with most downrod style AC fans. It is not recommended for use with hugger style fans, wall-mounted fans, or exhaust-type fans. It supports incandescent light bulbs and some dimmable LED lamps. Other LED lamps and CFL lamps may only support ON/OFF functionality without dimming. This fan light switch does NOT support Wi-Fi.

Compatibility chart showing compatible downrod fans and incompatible wall-mounted or exhaust fans, along with compatible incandescent/dimmable LED bulbs and incompatible CFL bulbs.

Figure 3: Fan and Bulb Compatibility Overview

4.4 Installation Video

Watch this video for a visual guide on the installation process and product overview.

Video 1: Overview of the Sunmerit Ceiling Fan Remote and Dimmer Combo Kit, including components and basic wiring concepts.

5. Operating Instructions

5.1 Wall Switch Control

The wall switch provides direct control over your fan and light. It features buttons for fan ON/OFF, fan speed adjustment (+/-), and light ON/OFF/Dimming. Indicator lights show the current fan speed setting.

Image showing a hand pressing the wall switch to control a ceiling fan and light in a living room setting.

Figure 4: Wall Switch in Use

5.2 Remote Control

The handheld remote offers convenient control from anywhere in the room. It includes buttons for Low, Medium, High fan speeds, Fan OFF, Light ON/OFF, and a timer function (1H, 2H, 4H, 8H).

Image showing a hand holding the remote control, with buttons for fan speed (Low, Med, High, Off) and light control, along with a ceiling fan in the background.

Figure 5: Remote Control Functions

5.3 Functionality Video

This video demonstrates the various functions of the Sunmerit Ceiling Fan Switch Combo.

Video 2: Demonstration of fan speed control, light ON/OFF, and dimming features using the wall switch and remote.

6. Maintenance

  • Cleaning: Wipe the remote and wall switch with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Battery Replacement: The remote control requires a 9V battery. Replace the battery when the remote's range decreases or it stops responding.
  • Regular Checks: Periodically check all wiring connections for tightness and signs of wear.

7. Troubleshooting

ProblemPossible CauseSolution
Fan or Light not respondingNo power to the unit; DIP switches not matched; Remote battery low/dead.Check circuit breaker; Ensure DIP switches on remote, wall switch, and receiver match; Replace remote battery.
Interference with other fansDIP switch code is the same as another nearby fan.Change the DIP switch settings on the affected units to a unique combination.
Light does not dimIncompatible light bulb (non-dimmable LED or CFL).Ensure you are using incandescent or dimmable LED bulbs.
Fan speed seems lower than expectedFan's internal settings or motor type.Ensure the fan's pull chain (if any) is set to its highest speed before using the remote/wall switch. This kit is designed for AC motors.

8. Specifications

FeatureSpecification
Operation ModeON-OFF
Current Rating1 Amps
Operating Voltage120 Volts
Contact TypeNormally Open
Connector TypeCrimp
TerminalScrew
Item Dimensions (L x W x H)6.42 x 6.42 x 2.36 inches
Circuit Type1-way
Contact MaterialBrass
International Protection RatingIP44
Number of Positions1
Upper Temperature Rating40 Degrees Celsius
Controller TypePush Button
Control MethodRemote
Unit Count3.0 Count
Number of Items3
Item Weight13.7 ounces
MaterialBrass

9. Warranty and Support

For warranty information or technical support, please refer to the product packaging or contact Sunmerit customer service directly. Keep your purchase receipt for any warranty claims.

Ask a question about this manual