RDCBC2 1P+N DIN Rail Smart Meter User Manual
Model: AVXANKTG RDCBC2/RDCBCL
Brand: AVXANKTG
1. Product Overview
The AVXANKTG RDCBC2 1P+N DIN Rail Smart Meter is a versatile circuit breaker designed for power consumption monitoring and control. It integrates multiple functions including a switch, time relay, voltmeter, ammeter, and power meter, with current limiting capabilities. This device is suitable for DIN rail mounting and operates within a wide voltage range, offering smart control features.
It is primarily a Ground Fault Circuit Interrupter (GFCI) type circuit breaker, ensuring electrical safety.

Figure 1: Front view of the RDCBC2 1P+N DIN Rail Smart Meter, showing the input (IN) and output (OUT) terminals, N and L connections, and control buttons for "The leakage test" and "on - off".
2. Safety Information
WARNING: Electrical shock hazard. Installation and servicing should only be performed by qualified personnel. Disconnect power before installation or maintenance.
- Ensure the main power supply is disconnected before handling the device.
- Verify correct wiring according to the provided diagrams.
- Do not exceed the rated voltage (220V) or current (1-63A) of the device.
- Operate within the specified working temperature range (-25℃ to 70℃).
- This device is designed for indoor use in dry environments.
3. Installation
3.1 Package Contents
- 1 x RDCBC2 1P+N DIN Rail Smart Meter
3.2 Mounting
The RDCBC2 is designed for DIN rail mounting. Ensure the DIN rail is securely installed within an electrical enclosure or panel.
- Align the device with the DIN rail.
- Press the device firmly onto the rail until it clicks into place.
- Verify that the device is securely fastened and does not wobble.
3.3 Wiring Diagram
Refer to the diagram below for proper wiring connections. The device features clearly marked "IN" (Input) and "OUT" (Output) terminals, with "N" for Neutral and "L" for Live connections.

Figure 2: Wiring diagram and physical dimensions of the RDCBC2 1P+N DIN Rail Smart Meter. The diagram shows the internal circuit representation and the connection points for N (Neutral) and L (Live) at both input and output. Dimensions are provided in millimeters.
- Connect the incoming Live (L) and Neutral (N) wires to the "IN" terminals.
- Connect the outgoing Live (L) and Neutral (N) wires to the "OUT" terminals, leading to the load.
- Ensure all connections are tight and secure to prevent loose contacts and overheating.
4. Operation
4.1 Basic Functions
- Switch: Controls the power flow to the connected load.
- Time Relay Switch: Allows for scheduled power on/off operations.
- Voltmeter: Displays the current voltage of the circuit.
- Ammeter: Displays the current flowing through the circuit.
- Power Meter: Measures and displays power consumption (kWh).
- Current Limit: Protects the circuit by limiting the maximum current.
4.2 Control Buttons
The device features two main control buttons on its front panel:
- "The leakage test" Button: Used to perform a manual leakage test to verify the Ground Fault Circuit Interrupter (GFCI) functionality. Press this button periodically to ensure proper safety operation.
- "on - off" Button: Toggles the power supply to the connected load. Press once to turn on, press again to turn off.
4.3 Smart Features
This smart meter supports advanced control and monitoring capabilities:
- Remote Control: Control the device from anywhere via a compatible application (details not provided in product description, typically Wi-Fi based).
- Voice Control: Integrate with voice assistants for hands-free operation (details not provided, typically requires smart home hub).
- Data Sharing: Share power consumption data (details not provided, typically via app).
5. Specifications
| Parameter | Value |
|---|---|
| Type | Circuit Breaker (Ground Fault Circuit Interrupter) |
| Model | RDCBC2/RDCBCL |
| Rated Voltage | 220V |
| Working Voltage | AC100-240V |
| Working Current | 1-63A |
| Frequency | 50/60Hz |
| Mechanical Life | > 100,000 times |
| Working Temperature | -25℃ to 70℃ |
| Certification | CE |
| Origin | Mainland China |
| Package Dimensions | 1.18 x 0.79 x 0.39 inches |
| Item Weight | 1.76 ounces |
| Assembly Required | No |
6. Maintenance
- Regular Inspection: Periodically inspect the device for any signs of physical damage, loose connections, or discoloration.
- Leakage Test: Press the "The leakage test" button monthly to ensure the GFCI function is operating correctly. The device should trip, cutting off power. Reset the device after the test.
- Cleaning: Use a dry, soft cloth to clean the exterior of the device. Do not use liquid cleaners or solvents.
- Power Cycle: If the device behaves unexpectedly, try power cycling it by turning off the main power supply, waiting a few minutes, and then restoring power.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | No incoming power; incorrect wiring; internal fault. | Check main power supply. Verify wiring connections. If problem persists, contact support. |
| Device trips frequently. | Overcurrent; ground fault; faulty appliance. | Reduce load. Check connected appliances for faults. Perform leakage test. |
| Readings are inaccurate. | Loose connections; internal sensor issue. | Ensure all wiring connections are secure. If problem persists, contact support. |
| Smart features not working. | No Wi-Fi connection; app issue; incorrect setup. | Check Wi-Fi network. Reconfigure smart features in the app. Refer to app-specific instructions. |
8. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.