Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the IONQXIDLD EAMPDW-TY-63S Smart Circuit Breaker. This device is designed to offer comprehensive electrical protection, including over-voltage, under-voltage, over-current, and leakage protection, along with energy metering capabilities. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.
Safety Information
WARNING: Electrical installation should only be performed by qualified personnel. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect power before installing or servicing the device.
- Ensure all wiring connections are secure and comply with local electrical codes.
- Do not operate the device if it appears damaged.
- Keep the device away from water and excessive moisture.
Product Overview
The EAMPDW-TY-63S is a smart energy protector device that integrates circuit breaking, energy metering, and various protection functions. It features a digital display for voltage, current, and energy consumption, along with control buttons for settings.

Figure 1: Front and side view of the EAMPDW-TY-63S Smart Circuit Breaker, showing its dimensions (85mm height, 36mm width, 65mm depth, 45mm width, 51mm height) and a table of adjustable protection parameters. The display shows voltage (220V), current (0.0A), and energy (0.0 kWh).
Specifications
| Parameter | Value |
|---|---|
| Model | EAMPDW-TY-63S |
| Rated Voltage | AC 220V (Single-phase) |
| Operating Voltage Range | AC 80V-400V |
| Rated Current | 1-63A (Adjustable) |
| Rated Frequency | 50/60Hz |
| Over Voltage Protection (>U) | 120V-300V (Adjustable, Default: 275V) |
| Under Voltage Protection (<U) | 80V-210V (Adjustable, Default: 175V) |
| Current Limit Protection | 1A-63A (Adjustable, Default: 63A) |
| Current Leakage Protection | 10-99mA (Adjustable, Default: 50mA, Can be turned off) |
| Reconnect Delay Time | 10s-99s (Adjustable, Default: 30s) |
| Over Current/Leakage Reconnect Attempts | 1-30/Off (Adjustable, Default: 5, Can be turned off) |
| Temperature Protection | 10-85°C (Adjustable, App-only setting) |
| Power Display Range | 0-99999.9 kWh |
| Operating Temperature | -30 to 70°C |
| Installation | 35mm DIN Rail |
| Protection Level | IP20 |
| Output Contact | 1NO |
| Certification | CE |
Setup and Installation
The EAMPDW-TY-63S Smart Circuit Breaker is designed for 35mm DIN rail installation.
- Power Disconnection: Before starting, ensure the main power supply to the installation area is completely disconnected.
- Mounting: Snap the device onto a standard 35mm DIN rail in your electrical panel.
- Wiring:
- Connect the incoming live (L) and neutral (N) wires to the "IN" terminals at the top of the device.
- Connect the outgoing live (L) and neutral (N) wires to the "OUT" terminals at the bottom of the device.
- Ensure all connections are tight and secure to prevent loose contacts and overheating.
- Power Restoration: Once all wiring is complete and verified, restore the main power supply. The device display should illuminate.
IMPORTANT: Incorrect wiring can damage the device or cause electrical hazards. If you are unsure, consult a qualified electrician.
Operating Instructions
The device features a digital display and control buttons for configuration and monitoring.
Display and Buttons:
- Display: Shows real-time voltage (V), current (A), and accumulated energy consumption (kWh).
- SET Button: Enters and confirms settings.
- Up/Down Arrows: Navigate through settings and adjust values.
- Power Button: Manually turns the circuit on/off.
Adjusting Protection Parameters:
Press the SET button to enter the parameter adjustment mode. Use the Up/Down arrows to select the parameter and adjust its value. Press SET again to confirm and move to the next parameter or exit.
| Parameter | Adjustable Range | Default Setting | Notes |
|---|---|---|---|
| Over Voltage (>U) | 120V-300V | 275V | Device trips if voltage exceeds this value. |
| Under Voltage (<U) | 80V-210V | 175V | Device trips if voltage drops below this value. |
| Current Limit Protection | 1A-63A | 63A | Device trips if current exceeds this value. |
| Current Leakage Protection | 10-99mA | 50mA | Can be turned off. Device trips if leakage current exceeds this value. |
| Reconnect Delay Time | 10s-99s | 30s | Delay before automatic reconnection after a trip. |
| Over Current/Leakage Reconnect Attempts | 1-30/Off | 5 | Number of automatic reconnection attempts. Can be turned off. |
| Temperature Protection | 10-85°C | N/A | This parameter is only set via the mobile application. |
Timing Modes (App-Controlled):
The device supports four timing modes, which are configurable via the associated mobile application:
- Scheduling Mode: Set specific times for the circuit to turn on/off.
- Countdown Mode: Set a countdown timer for the circuit to turn off.
- Cycle Timing Mode: Configure repetitive on/off cycles.
- Jog Mode: Momentary on/off control.
Maintenance
- Regularly inspect the device for any signs of physical damage or loose connections.
- Keep the device clean and free from dust. Use a dry, soft cloth for cleaning.
- Do not use abrasive cleaners or solvents.
- Ensure proper ventilation around the device to prevent overheating.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | No power supply; incorrect wiring. | Check main power supply. Verify wiring connections according to the installation section. |
| Device trips frequently. | Over-voltage, under-voltage, over-current, or leakage current detected. | Check the display for fault codes. Verify input voltage and load current. Adjust protection parameters if necessary, or investigate the cause of the electrical fault. |
| Cannot adjust temperature protection. | Temperature protection is app-only. | Use the dedicated mobile application to set temperature protection parameters. |
| Device does not reconnect automatically. | Automatic reconnect function is off or reconnect attempts exhausted. | Check the "Reconnect Times" and "Over Current/Leakage Reconnect Attempts" settings. Ensure they are enabled and attempts are not exhausted. |
Warranty and Support
For warranty information and technical support, please refer to the product packaging or contact your retailer. Keep your purchase receipt as proof of purchase.