1. Introduction
This manual provides essential instructions for the safe installation, operation, and maintenance of your AQUASTRONG PSP200 Single Speed 2HP Pool Pump. Please read this manual thoroughly before attempting to install or operate the pump. Retain this manual for future reference.

Image 1.1: The AQUASTRONG PSP200 Single Speed 2HP Pool Pump, showing its main components and power cord.
2. Safety Information
WARNING: Failure to follow these instructions can result in serious injury or death.
- Always disconnect power to the pump before performing any service or maintenance.
- Installation must be performed by a qualified professional and comply with all local and national electrical and plumbing codes.
- Ensure the pump is installed on a solid, level foundation to prevent vibration and noise.
- Do not operate the pump if it is damaged or has a frayed power cord.
- Keep children and pets away from the pump during operation.
- This pump is designed for use with swimming pools. Do not use it for other purposes.
- The pump operates on 115V. Ensure your electrical supply matches this requirement.
- The power cord is UL-certified for safety. Do not modify or extend the power cord.
3. Product Overview
3.1 Components

Image 3.1: Labeled diagram of the AQUASTRONG PSP200 Pool Pump components.
- 2" ID Inlet: Connection point for water entering the pump.
- 2" ID Out: Connection point for water exiting the pump.
- Filter Basket: Collects debris before water enters the pump impeller.
- Drain Plug: Used to drain water from the pump housing.
- Pure Copper Motor: The pump's driving mechanism.
- 5' Power Cord: Electrical connection for the pump.
- Earthing Terminal: Grounding point for electrical safety.
- Voltage Box: Enclosure for electrical connections.
- Lid Opener: Tool for removing the filter basket lid.
3.2 Key Features
- Versatile Compatibility: Suitable for both in-ground and above-ground pool systems.
- Durable Construction: Equipped with a UL-certified 6-foot power cord and an ETL-certified motor for reliable performance.
- Adaptable Fittings: Includes 1.5-inch and 2-inch internal diameter adapters for various plumbing connections.
- Continuous Duty Motor: Designed for consistent operation, providing high flow and efficient water circulation with low noise.

Image 3.2: The pump features a continuous duty motor for stable, quiet, and efficient operation.
- Detachable Filter Basket: An extra-large basket design for easy debris collection and cleaning.

Image 3.3: The detachable filter basket simplifies debris removal and cleaning.
- Safe UL Cord: Includes a 6-foot UL-tested power cord for enhanced safety.

Image 3.4: The pump is equipped with a 6-foot UL-certified power cord.
4. Specifications

Image 4.1: Technical specifications and output flow rate graph.
| Feature | Detail |
|---|---|
| Brand | AQUASTRONG |
| Model Number | PSP200 |
| Horsepower (HP) | 2HP |
| Voltage | 115V |
| Frequency | 60Hz |
| Maximum Flow Rate | 8917 GPH (148.62 Gallons Per Minute) |
| Maximum Head | 70 ft |
| Discharge ID | 2" |
| Amperage | 18A |
| Power Source | Corded Electric |
| Material | Plastic |
| Product Dimensions (L x W x H) | 24 x 8.3 x 11.8 inches (approximate) |
| Item Weight | 34.4 pounds |

Image 4.2: Approximate dimensions of the AQUASTRONG PSP200 Pool Pump.
5. Installation
5.1 Pre-Installation Checklist
- Ensure the installation site is level, dry, and well-ventilated.
- Verify that the electrical supply matches the pump's voltage (115V).
- Gather necessary tools and plumbing supplies (PVC pipes, PVC glue/cement, hose clamps, adapters if needed).
- Position the pump as close to the pool as possible to minimize friction loss in plumbing.
5.2 Plumbing Connections
The AQUASTRONG PSP200 pump includes two different adapters (1.5-inch and 2-inch internal diameter) to facilitate connection to various pool systems. Proper sealing is crucial to prevent leaks and ensure optimal pump performance.

Image 5.1: Illustration of outlet/inlet connection methods.
- Method 1: 1-1/2" Schedule 40 PVC Pipe Glue Connection
For a permanent and secure connection, use 1-1/2 inch Schedule 40 PVC pipe. Apply PVC glue/cement to the pipe and the inside of the adapter, then firmly connect them. Allow adequate drying time as per the adhesive manufacturer's instructions.
- Method 2: 1-1/2" Schedule 40 PVC Pipe Glue Connection + 2" PVC Hose with Clamp
This method offers flexibility. First, glue a 1-1/2 inch Schedule 40 PVC pipe to the adapter as in Method 1. Then, connect a 2-inch PVC hose to the pipe using a hose clamp to ensure a tight seal. Ensure all connections are leak-free.

Image 5.2: Visual guide for installing adapters and connecting PVC pipes.
Important: Always ensure a watertight seal for all plumbing connections to prevent air leaks, which can affect pump performance and lead to damage.
6. Operation
6.1 Initial Startup
- Ensure all plumbing connections are secure and the filter basket is clean and properly seated.
- Fill the pump housing with water through the skimmer or by removing the filter basket lid and pouring water directly into the basket area until the water level is above the pump's inlet. This primes the pump.
- Once primed, plug the pump into a grounded 115V electrical outlet. The pump is designed for plug-and-play operation and will start automatically.
- Observe the pump for any unusual noises or leaks. If the pump does not prime or operate correctly, refer to the Troubleshooting section.
6.2 Normal Operation
The AQUASTRONG PSP200 is a single-speed pump designed for continuous circulation. Allow the pump to run for several hours daily to ensure proper filtration and water circulation for your pool size. Consult your pool professional for recommended daily run times based on your pool volume and usage.
7. Maintenance
7.1 Cleaning the Filter Basket
Regular cleaning of the filter basket is essential for efficient pump operation and to prevent damage. The frequency depends on pool usage and debris levels.
- Disconnect Power: Always turn off and unplug the pump before cleaning.
- Remove Lid: Use the provided lid opener tool to carefully remove the filter basket lid.
- Remove Basket: Lift out the detachable filter basket.
- Clean Debris: Empty any collected leaves, hair, grit, or other debris from the basket. Rinse the basket thoroughly with water.
- Inspect O-Ring: Check the lid O-ring for cracks or wear. Lubricate with a silicone-based lubricant if dry.
- Reassemble: Place the clean basket back into the pump housing, ensuring it is seated correctly. Replace the lid and tighten it securely using the lid opener tool. Do not overtighten.
- Reprime: If necessary, re-prime the pump as described in the Initial Startup section before restoring power.

Image 7.1: The extra-large filter basket effectively captures various debris.
7.2 Winterization (for colder climates)
If you live in an area where temperatures drop below freezing, proper winterization of your pool pump is crucial to prevent damage.
- Disconnect Power: Turn off and unplug the pump.
- Drain Water: Remove the drain plug(s) from the pump housing to allow all water to escape. Store the drain plugs in the filter basket to prevent loss.
- Disconnect Plumbing: Disconnect the inlet and outlet plumbing from the pump.
- Store Pump: Clean the exterior of the pump and store it in a dry, warm, and protected area during the winter months.
8. Troubleshooting
Before contacting customer support, review the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power, tripped breaker, faulty motor. | Check power connection, reset circuit breaker. If motor is faulty, contact support. |
| Pump runs but no water flow | Pump not primed, air leak in suction line, clogged filter basket, closed valves. | Prime the pump, check all connections for air leaks, clean filter basket, open all necessary valves. |
| Low water flow | Clogged filter basket, partially closed valves, dirty filter, undersized plumbing. | Clean filter basket, ensure valves are fully open, clean pool filter, verify plumbing size. |
| Pump is noisy | Air leak in suction line, cavitation (lack of water), worn bearings. | Check for air leaks, ensure pump is fully primed, contact support if bearings are suspected. |
| Water leaking from pump | Loose connections, damaged O-rings/seals, cracked housing. | Tighten connections, inspect and replace O-rings/seals, contact support for housing damage. |
9. Warranty and Support
9.1 2-Year Limited Warranty
The AQUASTRONG PSP200 Pool Pump is backed by a 2-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, neglect, freezing, or unauthorized repairs.
Please retain your proof of purchase for warranty claims.
9.2 Customer Support
For technical assistance, warranty claims, or to inquire about replacement parts, please contact AQUASTRONG customer support. Refer to the product packaging or the AQUASTRONG website for the most current contact information.
When contacting support, please have your pump model number (PSP200) and date of purchase readily available.