WPTGODGB EAMPDW-TY-63C

EAMPDW-TY-63C 2P 63A LCD Digital Display Over and Under Voltage Current Protector kWh Energy Meter Leakage Timer Switch User Manual

Model: EAMPDW-TY-63C | Brand: WPTGODGB

1. Product Overview

The EAMPDW-TY-63C is a sophisticated 2P 63A LCD Digital Display Over and Under Voltage Current Protector, kWh Energy Meter, and Leakage Timer Switch. This device is designed to provide comprehensive electrical protection and monitoring for various applications, ensuring the safety and stability of your electrical system. It integrates multiple functions including voltage, current, and leakage protection, along with energy metering capabilities.

EAMPDW-TY-63C Digital Display Protector

Figure 1: Front view of the EAMPDW-TY-63C device, showing the LCD display and control buttons.

Key Features:

  • Undervoltage Protection: Adjustable range from 80V to 210V (default: 175V).
  • Overvoltage Protection: Adjustable range from 120V to 300V (default: 275V).
  • Overcurrent Protection: Adjustable range from 1A to 63A (default: 63A).
  • Leakage Protection: Adjustable from 10mA to 99mA (can be turned off).
  • Reconnection Delay Time: Adjustable from 10s to 90s (default: 30s).
  • Overcurrent and Leakage Reconnection Times: Adjustable from 1 to 30, or off (default: 5).
  • Temperature Protection: Adjustable from 10-85°C (App setting only).
  • Integrated Metering: Voltmeter, Ammeter, Electric Energy Meter (kWh).
  • Power Display Range: 0-99999.9kWh.
  • Energy Consumption Recording Range: 10-500kWh (default: 30kWh).
  • Smart Device Capability: Yes.

2. Setup and Installation

The EAMPDW-TY-63C is designed for easy installation on a standard 35MM guide rail. Ensure all power is disconnected before beginning installation to prevent electrical shock.

  1. Power Disconnection: Turn off the main power supply at the circuit breaker panel before handling any wiring. Verify with a voltage tester that no power is present.
  2. Mounting: Securely mount the device onto a 35MM DIN rail within your electrical panel. Ensure it clicks firmly into place.
  3. Wiring:
    • Connect the incoming live (L) and neutral (N) wires to the "IN" terminals at the top of the device.
    • Connect the outgoing live (L) and neutral (N) wires to the "OUT" terminals at the bottom of the device, leading to the protected circuit.
    • Ensure all connections are tight and secure to prevent loose contacts and overheating.
  4. Verification: Double-check all wiring connections for correctness and security.
  5. Power Restoration: Once installation is complete and verified, restore power to the circuit. The device's LCD display should illuminate.
EAMPDW-TY-63C Dimensions and Installation

Figure 2: Dimensions of the EAMPDW-TY-63C device, indicating its compact size for DIN rail installation.

3. Operating Instructions

The EAMPDW-TY-63C features an LCD display and control buttons for easy configuration and monitoring. Refer to the device's front panel for button layout (SET, up arrow, down arrow, power button).

3.1. Display Information

The LCD display provides real-time information:

  • Voltage (V): Current line voltage.
  • Current (A): Current load current.
  • Power (kWh): Accumulated energy consumption.
  • Leakage Current (mA): Detected leakage current (if function enabled).

3.2. Parameter Settings

To enter the setting mode, press and hold the "SET" button. Use the up and down arrow buttons to navigate through parameters and adjust values. Press "SET" again to confirm a value and move to the next parameter.

Table 1: Adjustable Parameters and Default Values
Parameter Adjustable Range Default Value Description
Undervoltage Protection (U<) 80V - 210V 175V Device trips if voltage drops below this value.
Overvoltage Protection (U>) 120V - 300V 275V Device trips if voltage exceeds this value.
Overcurrent Protection (I>) 1A - 63A 63A Device trips if current exceeds this value.
Reconnection Delay Time (t_delay) 10s - 90s 30s Time before automatic reconnection after a trip.
Leakage Protection (mA) 10mA - 99mA / OFF (Not specified, typically 30mA) Device trips if leakage current exceeds this value. Can be disabled.
Overcurrent/Leakage Reconnection Times 1 - 30 / OFF 5 Number of automatic reconnection attempts. Can be disabled.
Energy Consumption Recording Range 10kWh - 500kWh 30kWh Threshold for energy consumption recording.
Temperature Protection 10°C - 85°C (App setting only) Device trips if internal temperature exceeds this value.

Note: Temperature protection is only adjustable via the associated mobile application.

3.3. Manual Reset / Power Control

The power button on the front panel can be used to manually turn the device ON or OFF, or to reset it after a trip, if automatic reconnection is disabled or has reached its limit.

4. Maintenance

Regular maintenance ensures the longevity and reliable operation of your EAMPDW-TY-63C device.

  • Cleaning: Periodically wipe the device's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off before cleaning.
  • Inspection: Annually inspect wiring connections for tightness and signs of wear or corrosion. Ensure the device is securely mounted on the DIN rail.
  • Environment: Ensure the operating environment is within specified temperature and humidity ranges. Keep the device free from dust and moisture.
  • Functionality Check: Periodically test the protection functions if possible, following safety guidelines.

5. Troubleshooting

If you encounter issues with your EAMPDW-TY-63C, refer to the following common problems and solutions:

  • Device does not power on:
    • Check the main power supply to the circuit.
    • Verify that the input wires are correctly connected to the "IN" terminals.
    • Ensure the device is not in a tripped state (check display for error codes or indicators).
  • Device trips frequently:
    • Review the set protection parameters (undervoltage, overvoltage, overcurrent, leakage). They might be set too sensitively for your load.
    • Check the connected load for actual voltage, current, or leakage issues using external meters.
    • Inspect wiring for short circuits or ground faults.
  • Display is blank or unreadable:
    • Ensure stable power supply.
    • If the issue persists, the device may require professional inspection or replacement.
  • Cannot adjust settings:
    • Ensure you are pressing and holding the "SET" button long enough to enter the setting mode.
    • Follow the sequence of pressing "SET" to confirm and move between parameters.

For issues not covered here, please contact customer support.

6. Specifications

Table 2: Technical Specifications
Parameter Value
Model EAMPDW-TY-63C
Type Mini Circuit Breaker / Ground Fault Circuit Interrupter
Rated Voltage AC 220V (AC110/230V)
Working Voltage Range AC 80V - 400V (single phase)
Rated Current 1A - 63A (adjustable)
Rated Frequency 50/60Hz
Power Display Range 0 - 99999.9 kWh
Operating Temperature 30°C - 70°C
Installation 35MM Guide Rail (DIN Rail)
Protection Level IP20
Output Contact 1NO (Normally Open)
Is it a smart device? Yes
Package Dimensions 1.18 x 0.79 x 0.39 inches
Item Weight 1.76 ounces

7. Warranty and Support

Specific warranty information for the EAMPDW-TY-63C device is not available in the provided product data. Please refer to the product packaging or contact the manufacturer, WPTGODGB, or your point of purchase for detailed warranty terms and conditions.

For technical support, troubleshooting assistance beyond this manual, or inquiries regarding product functionality, please reach out to WPTGODGB customer service. Contact details are typically found on the product packaging or the manufacturer's official website.

© 2023 WPTGODGB. All rights reserved.

This manual is for informational purposes only. Specifications are subject to change without notice.

Related Documents - EAMPDW-TY-63C

Preview EARU EAMPDW-TY-63 Series WiFi Smart Energy Protector User Manual | Voltage, Current, Leakage Protection
Comprehensive user manual for the EARU EAMPDW-TY-63 Series WiFi Smart Energy Protector. Learn about installation, features, technical specifications, app control, and troubleshooting for voltage, current, and leakage protection.
Preview Earu EAMPDW-TY-63 Series WiFi Smart Energy Protector User Manual
User manual and technical specifications for the Earu EAMPDW-TY-63 Series WiFi Smart Energy Protector, detailing installation, app connection, parameter settings, and safety features.
Preview EARU EAMPDW-TY-63 Series WiFi Smart Energy Protector User Manual
Comprehensive user manual for the EARU EAMPDW-TY-63 series WiFi Smart Energy Protector, detailing features, installation, app connection, parameter settings, and troubleshooting. Covers over/under voltage, over current, leakage protection, energy monitoring, and remote control.
Preview EARU ELECTRIC EAMPDW-TY-63 WiFi Smart Circuit Breaker User Guide & Specifications
Detailed user guide and technical specifications for the EARU ELECTRIC EAMPDW-TY-63 series WiFi smart residual current circuit breaker, covering app integration, parameter settings, and safety features.