1. Setup
1.1 Unpacking
Carefully unpack the QM3G-43FH HMI PLC unit and all accessories from its packaging. Inspect the unit for any signs of damage during transit. Retain the original packaging for future storage or shipping.
1.2 Mounting
The QM3G-43FH is designed for panel mounting. Ensure the mounting surface is flat and stable. Cut an opening in the panel according to the specified cutout dimensions (refer to the Specifications section for exact measurements). Insert the unit into the opening and secure it using the provided mounting clips or screws.
1.3 Wiring
Before connecting any wires, ensure that the power supply is disconnected. Refer to the wiring diagram below for proper connections. This device requires a DC 24V input.

Figure 1: Rear panel of the QM3G-43FH HMI PLC. This image displays the various input/output terminals, communication ports (RS232, RS485, USB), and the DC 24V power input. The model number QM3G-43FH and version mView1.38 are visible on the label.
- Power Input (DC 24V): Connect the 24V DC power supply to the designated terminals. Ensure correct polarity. The OCR indicates 'INPUT:DC24V'.
- Digital Inputs (X00-X13): Connect your digital input signals to the 'X' terminals on the left side.
- Digital Outputs (Y00-Y13): Connect your digital output devices to the 'Y' terminals on the right side.
- Analog Inputs (AD0-AD3): Connect analog sensors or signals to the 'AD' terminals.
- Analog Outputs (DA0-DA1): Connect analog output devices to the 'DA' terminals.
- Communication Ports (COM1/COM2, RS232, RS485): Use the DB9 connector for RS232/RS485 communication. The device supports both RS232 and RS485 protocols.
- USB Host: For connecting USB devices such as flash drives for program transfer or data logging.
- Ethernet Port (LAN): Connect to a network for remote monitoring or programming (if applicable to the specific model variant).
- Grounding (FG): Ensure proper grounding of the unit to prevent electrical interference and ensure safety.
Caution: To prevent electric shock, do not remove the cover. No user serviceable parts are inside. Refer servicing to qualified personnel.
2. Operating Instructions
2.1 Powering On
- After completing all wiring, ensure connections are secure.
- Apply DC 24V power to the unit. The HMI screen will illuminate, and the system will begin its boot sequence.
- Wait for the operating system or the pre-loaded application to fully load.
2.2 Basic Navigation
The QM3G-43FH features a touch screen interface for user interaction. Navigate through menus and control parameters by touching the corresponding icons or buttons displayed on the screen. Specific navigation details will depend on the application program loaded onto the device.
2.3 Programming
The PLC functionality of this all-in-one unit is programmable using dedicated software. The device's version is mView1.38, indicating compatibility with specific programming environments. Refer to the software's user manual for detailed programming instructions, ladder logic development, and HMI screen design.
3. Maintenance
3.1 Cleaning
- Regularly clean the HMI touch screen with a soft, lint-free cloth.
- For stubborn marks, use a mild, non-abrasive screen cleaner. Do not spray cleaner directly onto the screen; apply it to the cloth first.
- Keep the ventilation openings clear of dust and debris to ensure proper heat dissipation.
3.2 Firmware Updates
Periodically check the manufacturer's website for available firmware updates. Firmware updates can provide new features, performance improvements, or bug fixes. Follow the provided instructions carefully when performing firmware updates to avoid damaging the device.
4. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not power on. | No power supply; incorrect voltage; loose wiring. | Check DC 24V power connection and voltage. Ensure all power wires are securely connected. |
| Touch screen unresponsive. | Screen calibration issue; software freeze; physical damage. | Restart the unit. If issue persists, check for screen calibration options in system settings or contact support. |
| PLC inputs/outputs not responding. | Incorrect wiring; programming error; faulty sensor/actuator. | Verify wiring according to the diagram. Check PLC program logic. Test external sensors/actuators independently. |
| Communication error (RS232/RS485). | Incorrect port settings; wrong cable; device not connected. | Verify baud rate, data bits, parity, and stop bits. Ensure correct cable type and secure connection. Check the connected device. |
5. Specifications
| Feature | Detail |
|---|---|
| Model Number | QM3G-43FH-24MT-4AD2DA-2PT2A4-A4-485P |
| Brand | EDRIWYIM |
| Type | HMI/PLC All-in-one |
| Series | QM3G |
| Input Voltage | DC 24V |
| ROM | NOR FLASH 8MB |
| RAM | 64MB |
| Communication | RS232, RS485, USB Host |
| Dimensions | 134*102*34 mm |
| Cutout Size | 120*94 mm |
| Firmware Version | mView1.38 |
| Item Weight | 50 Grams |
6. Warranty Information
This EDRIWYIM product is covered by a limited manufacturer's warranty. Please refer to the warranty card included with your purchase or visit the official EDRIWYIM website for detailed terms and conditions regarding warranty coverage, duration, and claims process. Keep your proof of purchase for warranty validation.
7. Support
For technical assistance, troubleshooting beyond this manual, or inquiries about your EDRIWYIM QM3G-43FH HMI PLC, please contact EDRIWYIM customer support. You can typically find contact information (email, phone, or support portal) on the manufacturer's official website. When contacting support, please have your model number and any relevant error messages ready.