1. Product Overview

The Zelinhol Sump Control Panel is designed for powerful flood protection, featuring a 110DB alarm and independent pump circuit. This robust system is suitable for various water level monitoring scenarios, offering durable, waterproof, and UL-certified safety for both indoor and outdoor installations. It provides peace of mind by automatically managing water levels and alerting users to potential flood threats.

Zelinhol Sump Control Panel with float switch and accessories

Figure 1: Zelinhol Sump Control Panel, including the main unit, float switch, and installation accessories.

Key Features:

  • Powerful Flood Protection: Detects water levels and activates alarms, with optional automatic pump drainage.
  • Independent Circuits: Separate pump and alarm circuits ensure continued alarm operation even if the pump circuit fails.
  • 110-Decibel Alarm: High-quality audio-visual flashing alarm with strong penetration for effective threat prevention.
  • Durable and Certified: IP67 waterproof housing for harsh environments, with UL-certified wiring and circuit breakers for safety and reliability.
  • Wide Applicability: Suitable for sewage pumps, water tanks, lift stations, and more. Pre-wired for easy installation.
Various scenarios where the Zelinhol Sump Control Panel can be used, including flooded basements and septic tanks.Diagram showing the wide range of applications for the Zelinhol Sump Control Panel, including water tanks, sewage tanks, and water towers.

Figure 2: The control panel is versatile for various water management needs, from residential to industrial applications.

2. Setup and Installation

Before beginning installation, ensure all power is disconnected at the main circuit breaker to prevent electrical shock. Verify power is off using a voltage tester. The Zelinhol Sump Control Panel is designed for straightforward installation, but professional assistance is recommended for complex setups.

2.1. Wiring Instructions

Follow the steps below for proper wiring. Refer to the internal wiring diagram inside the control panel for detailed connections.

2.1.1. Power Supply Wiring (Left Cable Gland)

Feed the power cable through the LEFT cable gland. Connect the wires according to the color code:

  • BLACK wire: Connect to the [L1] terminal (Live Wire).
  • WHITE wire: Connect to the [N] terminal (Neutral Wire).
  • GREEN wire: Connect to the GROUND BUSBAR (copper strip) (Earth Wire).

Video 1: Detailed steps for wiring the power supply to the Zelinhol Sump Control Panel. This segment covers disconnecting power, verifying safety, and connecting the live, neutral, and earth wires.

2.1.2. Pump Motor Wiring (Center Cable Gland)

Feed the pump cable through the CENTER cable gland. Connect the wires as follows:

  • BLACK wire: Connect to the [P1] terminal.
  • WHITE wire: Connect to the [N] terminal.
  • GREEN wire: Connect to the GROUND BUSBAR.

Video 2: Instructions for connecting the pump motor wires to the control panel, including proper terminal identification and grounding.

2.1.3. Float Switch Wiring (Right Cable Gland)

Feed the float switch cable through the RIGHT cable gland. Ensure the float weight orientation is correct for desired operation (e.g., normally open or normally closed). Connect the wires:

  • BLACK wire: Connect to the [3] terminal.
  • BROWN wire: Connect to the [4] terminal.
  • BLUE wire: Connect to the [5] terminal.

Video 3: Guide for wiring the float switch to the control panel, emphasizing correct wire connections and float weight setup.

After all wiring is complete, securely close the control panel cover.

3. Operation

3.1. Testing the Alarm

To test the alarm function:

  1. Ensure the main power is connected to the control panel.
  2. Turn the switch on the control panel to the "TEST" position. The alarm light should illuminate, and the 110-decibel alarm should sound.
  3. Turn the switch back to the "RUN" position to deactivate the test alarm.

Video 4: Demonstration of the alarm test function, showing how to activate and deactivate the alarm using the control panel switch.

3.2. Understanding Working Modes

The Zelinhol Sump Control Panel supports multiple working modes based on your setup:

  • Mode 1: Connect the float switch only. The panel will provide high-water level alarming.
  • Mode 2: External submersible pump only. The panel can control an external pump for drainage.
  • Mode 3: Connect the float switch and external water pump. The panel will provide high-water level alarming and can automatically start the external pump for drainage when the water level reaches the preset alarm line.
Diagram illustrating three different working modes for the Zelinhol Sump Control Panel: float switch only, external submersible pump only, and both connected.

Figure 3: Visual representation of the three operational modes for the control panel.

To activate the pump motor power circuit breaker, ensure the switch is in the "RUN" position and the circuit breaker is in the "ON" position. The float switch will then control the pump operation based on water levels.

Video 5: Demonstration of the pump motor power circuit breaker and its interaction with the float switch for automatic operation.

For optimal performance, install the float switch at the desired water level. The float weight can be adjusted to set the activation point.

Video 6: Instructions on how to install and adjust the float switch for precise water level monitoring.

4. Maintenance

Regular maintenance ensures the longevity and reliable operation of your Zelinhol Sump Control Panel.

  • Monthly Inspection: Visually inspect the control panel and float switch for any signs of damage, wear, or corrosion.
  • Functionality Test: Periodically test the alarm function as described in Section 3.1 to ensure it is working correctly.
  • Cleanliness: Keep the control panel and float switch free from debris, dirt, and obstructions that could interfere with their operation.
  • Wiring Check: Annually, with power disconnected, check all wiring connections to ensure they are secure.

5. Troubleshooting

If you encounter issues with your Zelinhol Sump Control Panel, consider the following common troubleshooting steps:

ProblemPossible CauseSolution
Alarm not sounding/light not flashing during test.No power to the unit; faulty wiring; damaged alarm component.Check power supply and circuit breaker. Verify all wiring connections. Contact customer support if components are faulty.
Pump not activating/deactivating.Float switch obstructed or faulty; pump motor issue; incorrect wiring.Ensure float switch moves freely. Check pump motor for functionality. Review pump motor wiring.
Intermittent alarm/pump operation.Loose wiring connections; debris interfering with float switch.Inspect and tighten all wiring connections. Clean the float switch and surrounding area.

For issues not listed or if troubleshooting steps do not resolve the problem, please contact Zelinhol customer support.

6. Specifications

FeatureDetail
BrandZelinhol
Model NumberZSPA-01
Item Weight4.65 pounds
Product Dimensions7.32 x 5.2 x 10.86 inches
Sound Level110 dB
Included ComponentsExternally Mounted Pump Test Switch, Float Switch, Pre-Wiring
Waterproof RatingIP67 (housing)
Safety CertificationUL Certified (wiring and circuit breakers)
Internal view of the Zelinhol Sump Control Panel showing circuit breakers, wiring, and waterproof plugs.Dimensions of the Zelinhol Sump Control Panel and its float switch components.

Figure 4: Detailed views of the control panel's internal components and overall dimensions.

7. Warranty and Support

Zelinhol products are backed by a manufacturer's warranty. For specific warranty details, claims, or technical support, please refer to the warranty card included with your product or visit the official Zelinhol website.

For immediate assistance, you may also contact the seller directly through the platform where the product was purchased.

Ask a question about this manual