1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of your Jemay Smoke and Carbon Monoxide Detector Combo. This device is designed to provide early warning of both smoke and carbon monoxide presence, enhancing the safety of your home and loved ones. Please read this manual thoroughly before installation and retain it for future reference.

Figure 1: Jemay Smoke and Carbon Monoxide Detector Combo Unit
2. Key Features
- 2-in-1 Protection: Detects both smoke (photoelectric sensor) and carbon monoxide (electrochemical sensor) for comprehensive safety.
- Critical 15-Second Early Alert: Utilizes bell-mouth technology for rapid smoke detection, providing an earlier warning than standard UL9th.
- Bilingual Voice Reminder: Provides voice alerts in English and French for threats, low battery, or malfunctions.
- Low False Alarms: Dual light wave detection technology minimizes false alarms from cooking or steam.
- Hardwired with Replaceable Battery Backup: Operates on 120V AC power with 2 AA replaceable batteries for uninterrupted protection during power outages.
- Wired Interconnection: Connects up to 18 devices, ensuring all alarms sound simultaneously when one is triggered.
- Smart Safety Features: Includes a low-battery chirp with a 10-hour non-disturb mode and a photoelectric smoke sensor to reduce nuisance alarms.
3. Important Safety Information
WARNING: This device is designed to detect smoke and carbon monoxide. It is not designed to detect fire, heat, or other gases. It is not a substitute for property, disability, life, or other insurance of any kind. Always ensure proper installation and regular testing.
- Never ignore any alarm. Failure to respond can result in serious injury or death.
- Test the alarm weekly to ensure proper operation.
- Replace batteries promptly when a low battery warning is issued.
- Do not paint the detector. Paint can clog the sensing chambers and prevent the unit from operating properly.
4. Package Contents
Verify that all items are present in the package:
- Jemay Smoke and Carbon Monoxide Detector Unit
- Mounting Plate
- Hardwiring Cable (3-wire)
- 2 AA Batteries
- Mounting Screws and Anchors
- Instruction Manual
- Dust Cover (for installation)
5. Setup and Installation
5.1. Choosing a Location
Install smoke and carbon monoxide alarms on every level of your home, including basements and attics. For optimal protection, install alarms inside each bedroom and outside every sleeping area. Keep alarms away from cooking appliances, heating vents, and areas with high humidity to prevent false alarms.
5.2. Mounting the Detector
- Disconnect Power: Before beginning installation, ensure that power to the circuit where the detector will be installed is turned off at the main service panel.
- Attach Mounting Plate: Secure the mounting plate to the ceiling or wall using the provided screws and anchors. Ensure the plate is firmly attached.
- Connect Hardwiring: Connect the hardwiring cable to your home's electrical wiring. The cable typically includes black (hot), white (neutral), and red (interconnect) wires. Match these to the corresponding wires in your electrical box.
- Install Batteries: Open the battery compartment on the back of the detector unit. Insert the 2 AA batteries, ensuring correct polarity (+/-). Close the compartment securely.
- Attach Detector Unit: Align the detector unit with the mounting plate and twist clockwise until it clicks firmly into place.

Figure 2: Hardwired AC Power Connector with Battery Backup

Figure 3: Interconnection of Multiple Alarms
6. Operating Instructions
6.1. Power-Up and Self-Test
Once installed and power is restored, the detector will perform a self-test. The LED indicator will flash green, and you may hear a brief chirp or voice announcement indicating it is powering up.
6.2. Testing the Alarm
Press and hold the large 'Test/Silence' button located in the center of the detector for a few seconds. The unit will emit a series of loud beeps and voice announcements (e.g., "Fire! Incendie!" or "Warning! Carbon Monoxide! Attention! Monoxyde de carbone!"). This confirms the alarm is functioning correctly.

Figure 4: Intelligent Bilingual Broadcasting
6.3. Silence Feature
In case of a nuisance alarm (e.g., from cooking smoke), press the 'Test/Silence' button to temporarily silence the alarm for approximately 10 minutes. The alarm will automatically reset after this period.
6.4. LED Indicators
- Green LED: Indicates normal operation and power.
- Yellow LED: Indicates a fault or low battery condition.
- Red LED: Indicates an alarm condition (smoke or carbon monoxide detected).
7. Maintenance
7.1. Regular Testing
Test your smoke and carbon monoxide detector weekly by pressing the 'Test/Silence' button. This ensures the electronic circuitry, alarm, and battery are working.
7.2. Battery Replacement
Replace the 2 AA batteries annually or immediately when the unit chirps and the yellow LED flashes, indicating a low battery. The unit features a 10-hour non-disturb mode for low battery status, allowing you to replace batteries at a convenient time without constant chirping.
7.3. Cleaning
Clean your detector at least once a month. Use a soft brush or a vacuum cleaner with a soft brush attachment to remove dust and debris from the vents and openings. Do not use water, cleaners, or solvents as these can damage the unit.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Nuisance/False Alarm | Cooking smoke, steam, high humidity, dust. | Press 'Test/Silence' button. Ventilate the area. Clean the detector. Relocate if consistently problematic. |
| Low Battery Chirp (Yellow LED) | Batteries are low. | Replace both AA batteries immediately. Utilize 10-hour non-disturb mode if needed. |
| Malfunction Alert (Yellow LED, specific voice) | Unit fault or sensor issue. | Clean the detector. If the issue persists, replace the unit. |
| No Power/No Indication | Power outage, loose wiring, dead batteries. | Check household circuit breaker. Ensure wiring is secure. Replace batteries. |
9. Specifications
| Feature | Detail |
|---|---|
| Brand | Jemay |
| Model | GS886A-3WCAR |
| Style | AC & RF |
| Power Source | Corded Electric (120V AC) with 2 AA Battery Backup |
| Product Dimensions | 5"D x 5"W x 2"H |
| Item Weight | 0.46 Pounds (7.4 ounces) |
| Alarm Type | Audible (85dB at 3 meters) with Voice Reminder |
| Sensor Type | Photoelectric (Smoke), Electrochemical (CO) |
| Interconnection | Wired (up to 18 devices) |
| Manufacturer | SITERWELL ELECTRONICS CO.,LIMITED |
10. Official Product Video
Video 1: Official product overview of the Jemay Smoke Detector Carbon Monoxide Detector Combo, demonstrating its features and operation.
11. Warranty and Support