1. Important Safety Information
Always follow the manufacturer's instructions for assembly, use, and maintenance. Keep the bed on a stable surface and avoid sudden movements when adjusting positions to prevent tipping. Do not leave children unattended near the bed. Always check the load capacity before use to ensure safety.
Weight Capacity: This bed is designed to support a maximum weight of 550 lbs (250 kg).
Electrical Safety: Ensure the power cord is not damaged and is properly connected to a grounded outlet. Avoid exposing electrical components to moisture.
2. Product Components and Overview
The VEVOR Premium 5-Function Full Electric Hospital Bed is designed for comfort and functionality in various care settings. Key components include:
- Bed Frame: Constructed from alloy steel and plastic for durability.
- Mattress: 15cm memory foam mattress, waterproof and easy to clean.
- Side Rails: Integrated safety guardrails.
- Head and Foot Boards: Quick-release design for easy access.
- Casters: Five-inch lockable aluminum casters for mobility and stability.
- Control Panels: Nurse control panel and side rail control panel.
- IV Pole: Included for medical applications.

Figure 2.1: Overview of the VEVOR Premium 5-Function Full Electric Hospital Bed.

Figure 2.2: Labeled components including headboard, IV pole, side rail, bed board, foot board, caster, bed frame, drainage hook, and CPR release.
3. Setup and Assembly
Assembly of the VEVOR hospital bed is required. Due to the bed's weight (approximately 146.5 kg / 323 lbs), it is strongly recommended to have 3-4 people assist with unpacking and assembly, especially if stairs are involved.
3.1 Unpacking
- Carefully remove all components from the packaging.
- Verify that all parts listed in the packing list (refer to the separate assembly guide) are present and undamaged.
3.2 Assembly Steps
For detailed, step-by-step assembly instructions, please refer to the dedicated assembly manual included with your product. General steps include:
- Assemble the main bed frame components.
- Attach the head and foot boards.
- Install the side rails.
- Place the mattress onto the bed frame.
- Ensure all casters are securely attached and functional.
- Connect the power cord to a suitable electrical outlet.
3.3 Caster Operation

Figure 3.1: The 5-inch aluminum casters provide smooth mobility and feature a locking mechanism for stability.
The bed is equipped with 5-inch lockable casters. To move the bed, ensure all casters are unlocked. To secure the bed in place, engage the locking mechanism on each caster by pressing down the lever.
4. Operating Instructions
The VEVOR hospital bed offers 5 adjustable functions and a cardiac chair position, controlled via two user-friendly panels.
4.1 Control Panels
The bed can be adjusted using either the Nurse Control Panel or the Side Rail Control Panel. Both panels provide intuitive control over all bed functions.

Figure 4.1: User-friendly control panel illustrating various adjustment buttons.

Figure 4.2: Overview of the Nurse Control Panel and Side Rail Control Panel options.
4.2 Adjustable Functions
The bed offers the following adjustments:
- Cardiac Chair Position: Provides a comfortable and therapeutic seating position.
- Trendelenburg & Reverse Trendelenburg: Adjusts the bed's tilt angle from 0° to 12°.
- Full Bed Elevation: Adjusts the overall bed height from 17.9 inches to 29.3 inches (455 mm to 745 mm).
- Backrest Angle: Adjusts the backrest from 0° to 75°.
- Leg Position: Adjusts the leg section from 0° to 32°.

Figure 4.3: A patient demonstrating the various flexible adjustments of the bed, including cardiac chair, Trendelenburg, and reverse Trendelenburg positions.
4.3 Control Panel Button Functions (Refer to Figure 4.1)
- Raise Back Rest: Elevates the back section of the bed.
- Lower Back Rest: Lowers the back section of the bed.
- Back Up Button: (Specific function, refer to detailed manual)
- Lower Knee Rest: Lowers the knee section of the bed.
- Raise Back + Knee Rest: Elevates both back and knee sections simultaneously.
- Lower Back + Knee Rest: Lowers both back and knee sections simultaneously.
- Raise Bed: Elevates the entire bed frame.
- Lower Bed: Lowers the entire bed frame.
- Raise Back Rest: (Duplicate, refer to detailed manual for specific function)
- Trendelenburg: Tilts the entire bed with the head lower than the feet.
- Lock Back Rest: Locks the backrest position.
- Lock Knee Rest: Locks the knee rest position.
- Lock Height Adjustment: Locks the bed height.
- Lock Trendelenburg: Locks the Trendelenburg position.
- Power On/Off: Turns the bed's power on or off.
- Emergency Stop: Immediately stops all bed movements.
- Trendelenburg: (Duplicate, refer to detailed manual for specific function)
- Cardiac Position: Activates the cardiac chair position.
- Nursing Position: Activates a pre-set nursing position.
- Patient Mobilization: Activates a pre-set position for patient mobilization.
- CPR: Activates the CPR function, quickly flattening the bed.
5. Maintenance and Care
Regular maintenance ensures the longevity and safe operation of your VEVOR hospital bed.
5.1 Cleaning
- Bed Frame: Wipe down the alloy steel and plastic surfaces with a damp cloth and mild disinfectant. Avoid abrasive cleaners.
- Mattress: The memory foam mattress features a waterproof cover that is easy to clean and wipe. Use a damp cloth with mild soap or disinfectant. Ensure the mattress is dry before use.

Figure 5.1: The mattress features a waterproof PU fabric, designed to prevent liquid seepage and facilitate easy cleaning, while also helping to reduce pressure injuries.
5.2 Inspection
- Periodically check all bolts and fasteners to ensure they are tight.
- Inspect the power cord and electrical connections for any signs of wear or damage.
- Verify that the casters roll smoothly and their locking mechanisms function correctly.
- Ensure side rails operate smoothly and lock securely in both raised and lowered positions.
6. Troubleshooting
This section provides solutions to common issues you might encounter.
6.1 Bed Not Responding to Controls
- Check Power: Ensure the bed is properly plugged into a functional electrical outlet and the power switch (if present) is in the 'ON' position.
- Emergency Stop: Verify that the emergency stop button (if present on your model) has not been activated. Reset if necessary.
- Control Panel Connection: Check that the control panels are securely connected to the bed's electrical system.
6.2 Casters Not Locking/Unlocking
- Inspect Mechanism: Check for any obstructions or damage to the caster locking levers.
- Clean Casters: Remove any debris (hair, lint) that might be interfering with the caster's movement or locking mechanism.
6.3 Unusual Noises During Operation
- Lubrication: Moving parts may require lubrication. Consult the detailed assembly manual for recommended lubrication points.
- Obstructions: Check for any objects caught in the bed's moving mechanisms.
If you encounter issues not covered here or require further assistance, please contact VEVOR customer support.
7. Specifications
Detailed technical specifications for the VEVOR Premium 5-Function Full Electric Hospital Bed (Model V8v8c-CPR).

Figure 7.1: Visual representation of bed dimensions and key specifications.

Figure 7.2: Comprehensive table of product specifications.
| Specification | Value |
|---|---|
| Item Model Number | V8v8c-CPR |
| Weight Capacity | 550 lbs / 250 kg |
| Mattress Dimensions | 35.4 x 75.8 inches / 900 x 1925 mm |
| Whole Bed Elevation | 17.9 - 29.3 inches / 455 - 745 mm |
| Backrest Elevation Angle | 0° - 75° |
| Legrest Elevation Angle | 0° - 32° |
| Trendelenburg Angle | 0° - 12° |
| Reverse Trendelenburg Angle | 0° - 12° |
| Net Weight | 146.5 kg / 323 lbs |
| Product Dimensions (L x W x H) | 82.1 x 40.4 x 17.9 - 29.3 inches / 2085 x 1025 x 455 - 745 mm |
| Material | Alloy Steel, Plastic |
| Color | White and Blue |
| Assembly Required | Yes |
| UPC | 197988216988 |
8. Warranty and Support
For specific warranty information regarding your VEVOR Premium 5-Function Full Electric Hospital Bed, please refer to the warranty card included with your product or contact VEVOR customer service directly. Warranty terms and conditions may vary.
If you require technical support, have questions about operation, or need replacement parts, please contact VEVOR customer support through their official website or the contact information provided in your product packaging.
You can visit the official VEVOR store for more information: VEVOR Store on Amazon