MDWXDOFP XSY-AT1 VFD Frequency Inverter User Manual

Models: 1.5KW, 2.2KW, 4KW (3-Phase 220V Output)

1. Safety Precautions

Read and understand all safety instructions before installing, operating, or maintaining the MDWXDOFP XSY-AT1 VFD Frequency Inverter. Failure to follow these instructions may result in serious injury, death, or property damage.

  • Risk of Electric Shock: Improper operation may cause severe injury or property loss. Always ensure power is disconnected before wiring or performing any maintenance.
  • Wiring Safety: Before wiring, confirm that the main power supply is completely off. Never connect the U/V/W output terminals to an AC power supply; this will damage the inverter.
  • Grounding: The inverter must be properly grounded to prevent electric shock.
  • Environment: Do not install the inverter in environments containing explosive gases, as this poses a fire hazard.
  • Professional Installation: Wiring and internal adjustments should only be performed by qualified professionals. The inverter contains high voltage internally; do not open the casing.
MDWXDOFP XSY-AT1 VFD Frequency Inverter front view with safety label

Image 1.1: Front view of the XSY-AT1 VFD, showing the control panel and a safety precautions label at the bottom.

2. Setup and Installation

2.1 Mounting

Mount the VFD in a vertical position on a stable, non-flammable surface, ensuring adequate ventilation for heat dissipation. Avoid direct sunlight, excessive dust, moisture, or corrosive gases. Maintain sufficient clearance around the unit for airflow.

2.2 Wiring

All wiring must be performed by a qualified electrician in accordance with local and national electrical codes. Ensure the main power supply is disconnected before beginning any wiring.

  • Input Power (R, S, T): Connect the 3-phase 220V AC power supply to the R, S, T terminals.
  • Output Power (U, V, W): Connect the motor to the U, V, W terminals. Do not connect these terminals to the AC mains.
  • Grounding (PE): Connect the ground terminal (PE) to a reliable earth ground.
  • Control Wiring: For external control (e.g., remote panel, external switches), refer to the detailed wiring diagram provided in the full product manual (not included here).
MDWXDOFP XSY-AT1 VFD Frequency Inverter with remote control panel

Image 2.1: The XSY-AT1 VFD unit shown with its detachable remote control panel, connected via a ribbon cable.

3. Operating Instructions

3.1 Control Panel Overview

The VFD features an intuitive control panel for direct operation and parameter setting.

Close-up of MDWXDOFP XSY-AT1 VFD control panel

Image 3.1: Close-up view of the XSY-AT1 VFD control panel, showing buttons and display.

  • Display: Shows current frequency, speed, or parameter values.
  • DISP: Toggles display modes.
  • FWD/REV: Changes motor rotation direction.
  • PROG: Enters/exits programming mode.
  • FUNC/DATA: Selects parameters or confirms data entry.
  • Up/Down Arrows: Adjust frequency or navigate parameters.
  • Rotary Knob: Fine-tunes frequency or parameter values.
  • RUN (Green): Starts the motor.
  • STOP/RESET (Red): Stops the motor or clears fault indications.

3.2 Basic Operation

  1. Power On: Apply 3-phase 220V power to the VFD. The display will illuminate.
  2. Set Frequency: Use the Up/Down arrows or the rotary knob to set the desired output frequency.
  3. Start Motor: Press the RUN button. The motor will accelerate to the set frequency.
  4. Change Direction: Press the FWD/REV button to reverse motor rotation while running or before starting.
  5. Stop Motor: Press the STOP/RESET button. The motor will decelerate and stop.

3.3 Parameter Setting

To access and modify advanced parameters (e.g., acceleration/deceleration times, motor parameters), press the PROG button to enter programming mode. Use the Up/Down arrows to navigate through parameter groups and the FUNC/DATA button to select and confirm values. Refer to the comprehensive programming manual for a full list of parameters and their functions.

4. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your VFD. Always disconnect power before performing any maintenance.

  • Cleaning: Periodically clean the VFD's exterior and cooling fins to prevent dust buildup, which can hinder heat dissipation. Use a soft, dry cloth. Do not use liquid cleaners.
  • Inspection: Regularly inspect wiring connections for tightness and signs of damage or corrosion. Check for any unusual noises or odors during operation.
  • Environmental Check: Ensure the operating environment remains within specified temperature and humidity ranges. Verify that ventilation is not obstructed.
  • Fan Check: For models with cooling fans, ensure they are operating correctly and free from obstructions.
Top view of MDWXDOFP XSY-AT1 VFD Frequency Inverter showing cooling fins

Image 4.1: Top view of the XSY-AT1 VFD, highlighting the cooling fins for heat dissipation.

5. Troubleshooting

This section provides basic troubleshooting steps for common issues. For complex problems, consult a qualified technician.

Problem Possible Cause Solution
VFD does not power on No input power; Blown fuse; Loose connection Check power supply; Inspect fuses; Verify all input wiring connections.
Motor does not run VFD in STOP mode; Incorrect frequency setting; Motor wiring issue; Fault condition Press RUN; Adjust frequency; Check motor connections (U, V, W); Check display for fault codes and reset.
Overcurrent fault (OC) Motor overload; Short circuit in motor/wiring; Rapid acceleration/deceleration Reduce motor load; Check motor and wiring for shorts; Increase acceleration/deceleration times in parameters.
Overvoltage fault (OV) High input voltage; Rapid deceleration with high inertia load Verify input voltage; Increase deceleration time; Consider adding a braking resistor if applicable.
Under voltage fault (UV) Low input voltage; Power supply fluctuation Verify input voltage stability; Check power supply capacity.

6. Specifications

The following specifications apply to the MDWXDOFP XSY-AT1 series VFD Frequency Inverter.

  • Model Series: XSY-AT1
  • Input Voltage: 3-Phase 220V AC
  • Output Voltage: 3-Phase 0-220V AC (proportional to frequency)
  • Output Frequency Range: 0-400 Hz (typical, configurable)
  • Rated Power Options: 1.5KW, 2.2KW, 4KW
  • Control Method: V/F Control
  • Operating Temperature: -10°C to 40°C (14°F to 104°F)
  • Humidity: 0-95% relative humidity (non-condensing)
  • Protection Features: Overcurrent, Overvoltage, Undervoltage, Overheat, Overload protection
Internal components of MDWXDOFP XSY-AT1 VFD Frequency Inverter with remote panel

Image 6.1: View of the internal components of the XSY-AT1 VFD, demonstrating its construction, alongside the remote control panel.

MDWXDOFP XSY-AT1 VFD Frequency Inverter User Manual. All rights reserved.