1. Product Overview
The NICGQMQR VFD Frequency Converter XSY-AT1 is a versatile inverter designed for controlling motor speed and torque. It supports 1.5KW, 2.2KW, and 4KW power outputs with a 3-phase 220V input. This device is suitable for various industrial and commercial applications requiring precise motor control.

Figure 1: Front view of the NICGQMQR VFD Frequency Converter (Model XSY-AT1).
2. Safety Precautions
Read all safety warnings and instructions carefully before installing or operating this device. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.
- Electrical Hazard: Ensure power is disconnected before any wiring or maintenance. Only qualified personnel should perform electrical connections.
- Grounding: The inverter must be properly grounded to prevent electric shock.
- Environment: Do not install in environments with explosive gas, flammable materials, or excessive moisture.
- Wiring: Incorrect wiring of U/V/W output and AC power supply can cause severe damage to the inverter.
- Internal Components: Do not open the inverter casing. High voltage is present inside, even after power is disconnected.

Figure 2: Important safety precautions label on the device's control panel.
3. Setup and Installation
This section details the steps for proper installation of the VFD Frequency Converter.
3.1 Unpacking
Carefully remove the inverter from its packaging. Inspect for any signs of damage during transit. Retain packaging for future transport or storage.
3.2 Mounting
Mount the inverter in a well-ventilated area, away from direct sunlight, excessive dust, moisture, or corrosive gases. Ensure sufficient clearance around the unit for heat dissipation.
3.3 Wiring Connections
Refer to the wiring diagram for correct connections. Ensure all connections are secure and properly insulated. Connect the input power (AC 220V, 3-phase) to the designated terminals and the motor to the U, V, W output terminals. Connect the ground wire to the grounding terminal.

Figure 3: Internal components and connection points of the inverter.

Figure 4: The VFD inverter with its remote control panel, illustrating the connection cable.
4. Operating Instructions
This section provides instructions on how to operate the VFD Frequency Converter.
4.1 Control Panel Overview
The control panel features a digital display, function buttons, and a rotary knob for frequency adjustment.

Figure 5: Detailed view of the VFD control panel.
- DISP: Display button to cycle through various parameters (frequency, current, voltage, etc.).
- PROG: Program button to enter parameter setting mode.
- FUNC/DATA: Function/Data button for navigating menus and confirming data.
- FWD/REV: Forward/Reverse button to change motor direction.
- Up/Down Arrows: Navigate through parameters or adjust values.
- RUN: Start button to initiate motor operation.
- STOP/RESET: Stop button to halt motor operation or reset errors.
- Rotary Knob: Adjusts output frequency or parameter values.
4.2 Basic Operation
- Power On: Connect the inverter to the power supply. The display will light up.
- Set Frequency: Use the rotary knob or arrow buttons to set the desired output frequency.
- Start Motor: Press the RUN button. The motor will start and accelerate to the set frequency.
- Change Direction: Press the FWD/REV button to switch motor rotation direction.
- Stop Motor: Press the STOP/RESET button. The motor will decelerate and stop.
5. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your VFD Frequency Converter.
- Cleaning: Periodically clean the exterior of the inverter with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure ventilation openings are free from dust and debris.
- Inspection: Regularly inspect wiring connections for looseness or damage. Check for any unusual noises or smells during operation.
- Environment: Maintain the operating environment within specified temperature and humidity ranges.
6. Troubleshooting
This section provides solutions to common issues you might encounter.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter does not power on. | No power supply; loose connections; internal fault. | Check power input; verify all wiring connections; contact technical support if fault persists. |
| Motor does not run. | Incorrect frequency setting; motor overload; wiring error. | Adjust frequency; check motor load; verify motor wiring (U, V, W). |
| Error code displayed. | Specific fault detected (e.g., overcurrent, overvoltage). | Refer to the full manual for specific error code meanings and solutions. Press STOP/RESET to clear. |
7. Specifications
Key technical specifications for the NICGQMQR VFD Frequency Converter.
| Feature | Detail |
|---|---|
| Model | XSY-AT1 |
| Input Voltage | 3-Phase 220V |
| Output Power (for this model) | 2.2KW |
| Item Weight | 1.76 ounces |
| Package Dimensions | 1.18 x 0.79 x 0.39 inches |
| Manufacturer | NICGQMQR |
8. Warranty and Support
For warranty information and technical support, please refer to the manufacturer's official website or contact your point of purchase. Keep your purchase receipt as proof of purchase.
Manufacturer: NICGQMQR