Molloparts 10-00431-07
Molloparts Contactor 10-00431-07 User Manual
For Carrier Transicold Applications
1. Introduction
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Molloparts Contactor, specifically models 10-00431-07, 100043107, 10-00431-01, 100043101, 10-00333-01, 100033301, 10-00431-12, and 100043112. This contactor is designed for compatibility with Carrier Transicold systems. Please read this manual thoroughly before proceeding with any procedures.
2. Safety Information
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before servicing.
- Always ensure power is disconnected at the source before beginning any work on the contactor or associated wiring.
- Use appropriate personal protective equipment (PPE), including insulated gloves and safety glasses.
- Verify correct voltage and current ratings before installation to prevent damage to the unit or system.
- Ensure all connections are secure and properly insulated.
- Do not operate the contactor if it appears damaged.
3. Product Overview
The Molloparts Contactor is a 4-pole electrical switching device designed for controlling power circuits in compatible Carrier Transicold units. It features three normally open (NO) contacts and one normally closed (NC) contact, with a coil rated for 20/24 Volts AC.
3.1 Part Numbers Covered
- 10-00431-07
- 100043107
- 10-00431-01
- 100043101
- 10-00333-01
- 100033301
- 10-00431-12
- 100043112
3.2 Package Contents
- 1 x Molloparts Contactor

Figure 1: Angled view of the Molloparts Contactor, illustrating the main power terminals and control coil connections.
4. Installation
Installation should be performed by a qualified technician familiar with electrical systems and Carrier Transicold equipment.
- Power Disconnection: Ensure all power to the Carrier Transicold unit is completely disconnected and locked out according to safety procedures.
- Identify Mounting Location: Locate the existing contactor or designated mounting area within the control panel.
- Mounting: Securely mount the new Molloparts Contactor using appropriate fasteners. Ensure it is stable and free from vibration.
- Wiring Power Circuits: Connect the main power lines (L1, L2, L3) to the input terminals and the load lines (T1, T2, T3) to the output terminals. Refer to the Carrier Transicold wiring diagram for correct phase sequence and load connections. Ensure all connections are tight.
- Wiring Control Circuit: Connect the 20/24 Volt AC control voltage to the coil terminals. Observe polarity if specified, though AC coils are typically non-polarized.
- Auxiliary Contacts: Connect any auxiliary control wiring to the normally open (NO) and normally closed (NC) auxiliary contacts as required by the system design.
- Verification: Double-check all wiring against the system's electrical schematic. Ensure no loose wires or exposed conductors.
- Power Restoration: Once all connections are verified and secure, restore power to the unit.

Figure 2: Top view of the contactor, showing the robust construction and terminal access points for wiring.
5. Operation
The Molloparts Contactor operates by receiving a control voltage (20/24V AC) across its coil. When the coil is energized, it creates an electromagnetic field that pulls the main contacts closed, allowing power to flow from the input (L1, L2, L3) to the output (T1, T2, T3) terminals. When the control voltage is removed, the coil de-energizes, and springs return the contacts to their open position, interrupting the power flow.
- Energizing: Apply 20/24V AC to the coil terminals to close the main contacts.
- De-energizing: Remove 20/24V AC from the coil terminals to open the main contacts.
- Auxiliary Contacts: The auxiliary contacts (3 NO, 1 NC) change state simultaneously with the main contacts, providing signals for control logic or interlocking.
6. Maintenance
Regular inspection and maintenance can help ensure the longevity and reliable operation of the contactor.
- Visual Inspection (Monthly): Check for any signs of physical damage, discoloration, or overheating on the contactor body, terminals, and wiring.
- Terminal Tightness (Annually): With power disconnected, verify that all terminal screws are tight to prevent loose connections and arcing.
- Contact Inspection (As needed): If operational issues arise, inspect the main contacts for excessive pitting or wear. This typically requires disassembly by a qualified technician.
- Cleaning: Keep the contactor free from dust and debris. Use a dry, non-conductive brush or compressed air for cleaning.
7. Troubleshooting
This section provides guidance for common issues. For complex problems, consult a qualified electrician or Carrier Transicold service technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Contactor does not energize (contacts do not close) | No control voltage to coil; Incorrect coil voltage; Open coil circuit; Mechanical obstruction. | Verify 20/24V AC at coil terminals; Check coil resistance; Inspect for foreign objects. |
| Contactor hums loudly | Loose laminations; Incorrect voltage; Dirt/debris on magnet faces. | Ensure proper mounting; Verify correct control voltage; Clean magnet faces (with power off). |
| Contactor contacts weld or stick | Overcurrent condition; Short circuit; Frequent cycling; Worn contacts. | Investigate and correct overcurrent source; Replace contactor if contacts are damaged. |
| Overheating | Loose connections; Overload; Incorrect voltage. | Tighten all terminals; Verify load current is within rating; Check control voltage. |
8. Specifications
Detailed technical specifications for the Molloparts Contactor.

Figure 3: Side view of the contactor, displaying the manufacturer's specification label with electrical ratings.
| Feature | Specification |
|---|---|
| Contactor Type | 4 Pole Contactor |
| Ampere Rating (600VAC) | 30A |
| Main Contacts | 3 Normally Open (NO) |
| Auxiliary Contacts | 1 Normally Closed (NC) |
| Coil Rated Voltage | 20/24 Volt AC, 50/60 Hertz |
| Coil Insulation Class | Class H |
| Item Weight | 14.4 ounces (approx. 408 grams) |
| Manufacturer Part Number | D31TCY7OC48CY9XM23N |
| Compatibility | Carrier Transicold |
9. Warranty Information
Molloparts products are manufactured to high standards. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Molloparts customer support directly. Keep your proof of purchase for warranty claims.
10. Customer Support
If you have any questions regarding the installation, operation, or troubleshooting of your Molloparts Contactor, please contact your supplier or Molloparts customer service. Provide the model number and a detailed description of your inquiry for efficient assistance.
Related Documents - 10-00431-07
![]() |
Roberts 10-56 Longneck Plus 6 in. Jamb Saw Replacement Parts List Official replacement parts list for the Roberts 10-56 Longneck Plus 6-inch Jamb Saw. Find part numbers, descriptions, and supplier information for maintaining your power tool. |
![]() |
ABI Force Z-23 Edger Attachment Installation Guide Detailed instructions and parts list for installing the ABI Force Z-23 Edger Attachment. Learn how to mount the edger tube, clean-up tool, and stabilizing wheel assembly. |
![]() |
Magnuson MOAB Drive Selection Guide Comprehensive guide from Magnuson Superchargers for selecting the correct MOAB cartridge assembly length, including step-by-step instructions, template usage, and detailed dimensions for various part numbers. |
![]() |
EXIT Smash Padel Rebounder Assembly Instructions Assembly instructions and parts list for the EXIT Smash Padel Rebounder. Learn how to set up your padel trainer with this step-by-step guide. |
![]() |
Tylö Relay Box Commercial Lite Installation and Connection Guide Detailed guide for the Tylö Relay Box Commercial Lite, covering installation, electrical connections, wiring diagrams, and modular contactor explanations for sauna heater systems. |
![]() |
Sepura TETRA/Nødnett Håndterminaler SC20 og SC21 Brukerveiledning (Brannvesen Oppsett) Detaljert brukerveiledning for Sepura TETRA/Nødnett håndterminaler, modeller SC20 og SC21, spesielt konfigurert for brannvesen. Dekker funksjoner som nød-alarm, CallOut, samtale, funksjoner og hurtigtaster. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.