CENSTECH DL2

CENSTECH DL2 Evaporative Air Cooler User Manual

Model: DL2

Important Safety Instructions

Please read all instructions carefully before using this appliance. Keep this manual for future reference.

  • Always ensure the unit is placed on a stable, level surface.
  • Do not operate the unit with a damaged cord or plug.
  • Do not immerse the unit, cord, or plug in water or other liquids.
  • Unplug the unit from the power outlet before cleaning, maintenance, or when not in use.
  • Keep children and pets away from the unit during operation.
  • Do not block air inlets or outlets.
  • Use only clean water in the water tank.
  • This appliance is for indoor use only.

Product Overview

The CENSTECH DL2 Evaporative Air Cooler functions as an air cooler, humidifier, and fan. It is designed to provide cooling and humidification, particularly effective in dry climates.

Package Contents

  • 1 x CENSTECH DL2 Evaporative Air Cooler
  • 6 x Upgraded Ice Packs
  • 1 x Remote Control (battery included)
  • 4 x 360° Swivel Wheels
  • 1 x User Manual

Unit Diagram

CENSTECH DL2 Evaporative Air Cooler front view

Figure 1: Front view of the CENSTECH DL2 Evaporative Air Cooler.

Setup

1. Unpacking and Wheel Installation

Carefully remove the air cooler from its packaging. The unit comes with detachable 360° swivel wheels for easy mobility. Attach the four wheels to the bottom of the unit by gently pushing them into the designated slots until they click into place. No screws are needed for this step.

Installing 360 degree swivel wheels on the base of the air cooler

Figure 2: Illustration of attaching the swivel wheels to the unit.

2. Filling the Water Tank

The unit features dual water tanks for convenient refilling. You can add water from the top or by pulling out the bottom tank. Ensure the unit is unplugged before filling.

  • Top Fill: Open the top cover and pour clean water directly into the reservoir.
  • Bottom Tank: Gently pull out the bottom water tank. Fill it with clean water, then slide it back into the unit until securely in place. The bottom tank has a visible water level indicator.

Do not exceed the maximum fill line. The 1-gallon capacity water tank provides up to 8 hours of continuous cooling.

Pouring water into the top of the air cooler

Figure 3: Demonstrating how to fill the water tank from the top.

3. Using Ice Packs

For enhanced cooling, use the provided ice packs. These pre-filled polymer solidified gel ice packs should be frozen for at least 3 hours before use. Place the frozen ice packs into the water tank along with the water. This can reduce ambient temperatures by 41-49°F.

Six blue ice packs next to ice cubes

Figure 4: The upgraded ice packs for enhanced cooling.

Setup and Operation Video Guide

Video 1: A detailed guide on how to set up and use the CENSTECH Evaporative Air Cooler.

Operating Instructions

The CENSTECH DL2 can be controlled via the touch panel on the top of the unit or using the included remote control.

Top touch panel and remote control for the air cooler

Figure 5: Touch panel and remote control for the air cooler.

1. Power On/Off

Press the POWER button on the control panel or remote to turn the unit on or off.

2. Adjusting Fan Speed

Press the SPEED button to cycle through three fan speeds: Low (12 ft/s), Medium (19 ft/s), and High (26 ft/s).

3. Selecting Operating Mode

Press the MODE button to choose between three operating modes:

  • Normal Mode: Standard fan operation.
  • Sleep Mode: Operates at a lower speed and noise level (40dB) for quiet environments, ideal for nighttime use.
  • Cooling Mode: Activates the evaporative cooling function. Ensure the water tank is filled and ice packs are added for optimal performance.
Diagram showing Normal, Cooling, and Sleep modes with fan speeds

Figure 6: Available modes and fan speeds.

Three images showing fan mode, humidifier mode, and air cooler mode

Figure 7: Visual representation of Fan, Humidifier, and Air Cooler functions.

4. Timer Function

Press the TIMER button to set an auto-off timer from 1 to 12 hours. The unit will automatically shut off after the selected duration, saving energy.

5. Oscillation

Press the SWING button to activate the 70° automatic horizontal oscillation, distributing cool air evenly across the room. The vertical airflow can be manually adjusted by 25°.

Air cooler oscillating 70 degrees to cover a wider area

Figure 8: The 70° oscillation feature for wider coverage.

Operation Overview Videos

Video 2: Demonstrates the 12-hour timer, 3 speeds, and 3 modes of the air cooler.

Video 3: Highlights the customizable comfort functions of the smart air conditioner.

Video 4: A short preview showcasing the sleek design, instant cooling, and quiet operation.

Maintenance

Regular cleaning and maintenance ensure optimal performance and longevity of your air cooler.

1. Cleaning the Cooling Pad and Water Tank

The cooling pad and water tank are removable for easy cleaning.

  • Before Cleaning: Always unplug the unit from the power outlet.
  • Remove Components: Carefully remove the cooling pad and detach the water tank.
  • Clean: Wash the cooling pad and water tank with mild soap and water. Rinse thoroughly to remove any residue.
  • Dry: Allow all components to air dry completely before reassembling.
  • Reassemble: Place the dry cooling pad back into its slot and reattach the water tank securely.
Removable water tank, cooling pad, and grill being cleaned with water

Figure 9: Removable components for easy cleaning.

2. Exterior Cleaning

Wipe the exterior of the unit with a soft, damp cloth. Do not use abrasive cleaners or solvents.

3. Storage

If storing the unit for an extended period, ensure it is clean and dry. Empty the water tanks completely. Store in a cool, dry place away from direct sunlight.

Troubleshooting

If you encounter issues with your CENSTECH DL2 Evaporative Air Cooler, please refer to the following common problems and solutions:

ProblemPossible CauseSolution
Unit does not power onNo power supply; Power cord not properly plugged in; Power button not pressed.Check power outlet; Ensure power cord is securely plugged in; Press the POWER button.
No or weak airflowAir inlets/outlets blocked; Fan speed set too low.Clear any obstructions; Increase fan speed using the SPEED button.
No cooling effectWater tank empty; Cooling mode not activated; No ice packs or ice added.Fill water tank; Select COOLING mode; Add frozen ice packs or ice to the water tank.
Water pump stops workingWater level too low.Refill the water tank. The unit automatically switches to fan mode if water runs out.
Remote control not workingBattery depleted; Obstruction between remote and unit.Replace remote control battery; Ensure clear line of sight to the unit's sensor.

If the problem persists after trying these solutions, please contact customer support.

Specifications

FeatureSpecification
BrandCENSTECH
Model NameDL2
MaterialPlastic
Mounting TypeFreestanding
ColorLight White
Air Flow Capacity1440 Cubic Feet Per Minute (CFM)
Controls TypeRemote Control & Touch Control
Reservoir Capacity1 Gallon
Floor Area CoverageUp to 300 sq. ft.
Item Weight9 Pounds
Wattage65 Watts
Noise Level40 Decibels (dB)
Number of Speeds3 (Low, Medium, High)
Voltage120 Volts
Operation ModeAutomatic
Item Dimensions (D x W x H)11"D x 10"W x 22"H
Oscillation70° Horizontal Auto-Swing, 25° Vertical Manual Adjustment
Timer1-12 Hour Auto-Off

Warranty and Support

Warranty Information

This CENSTECH Evaporative Air Cooler comes with a 1-year warranty from the date of purchase, covering manufacturing defects only.

Customer Support

For any questions or assistance, please reach out to CENSTECH customer service via Amazon or through the contact information provided in the manual instructions. You will receive a solution within 24 hours.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.