Hanna HI 98308 Pure Water Tester User Manual

Model: HI98308

Introduction

The Hanna HI 98308 Pure Water Tester is a rugged, reliable, and pocket-sized device designed to provide quick and accurate readings for the purity of distilled, demineralized, or pure water. It is an essential tool for laboratory and industrial environments where precise water quality monitoring is critical. This manual provides comprehensive instructions for the setup, operation, and maintenance of your HI 98308 tester.

Safety Information

Please read all instructions carefully before using the device. Failure to do so may result in inaccurate readings or damage to the unit. Keep the device away from extreme temperatures, direct sunlight, and corrosive chemicals. Do not immerse the entire device in water; only the electrode portion is designed for liquid contact. Always handle the device with clean, dry hands.

What's in the Box

  • Hanna HI 98308 Pure Water Tester
  • Cuvettes
  • Reagent starter kit
  • Battery
  • Instructions and quick start guide

Product Overview

Hanna HI 98308 Pure Water Tester, front view
Figure 1: Front view of the Hanna HI 98308 Pure Water Tester, showing the display and the main body.
Hanna HI 98308 Pure Water Tester with cap removed and calibration tool
Figure 2: The HI 98308 tester with its protective cap removed, revealing the electrode. A calibration screwdriver is also shown.
Close-up view of the Hanna HI 98308 Pure Water Tester electrode
Figure 3: A close-up view of the graphite electrodes and exposed temperature probe, designed for accurate and fast readings.
Hanna HI 98308 Pure Water Tester in use, measuring water in a beaker
Figure 4: The HI 98308 tester being used to measure the purity of water in a beaker, demonstrating its handheld operation.

The HI 98308 features a clear LCD display, a durable body, and a sensitive electrode system. The graphite electrodes minimize polarization effects, ensuring stable and reliable measurements. The exposed temperature probe allows for rapid temperature compensation, crucial for accurate conductivity readings.

Setup

1. Battery Installation

Locate the battery compartment on the back of the tester. Open the compartment cover and insert the provided battery, ensuring correct polarity. Close the cover securely.

2. Initial Calibration

The HI 98308 requires manual calibration to a single point for optimal accuracy. Refer to the included quick start guide for detailed instructions on performing this initial calibration using the reagent starter kit. Typically, this involves immersing the electrode in a known standard solution and adjusting the reading using the calibration screw (as shown in Figure 2) until it matches the standard's value.

Operating Instructions

1. Preparing for Measurement

  • Ensure the tester is clean and dry before use.
  • Remove the protective cap from the electrode.
  • Turn on the tester using the power button.

2. Taking a Measurement

  • Immerse the electrode into the pure water sample you wish to test. Ensure the electrodes are fully submerged.
  • Gently stir the sample to remove any air bubbles that may be trapped around the electrode.
  • Allow the reading on the display to stabilize. The HI 98308 provides readings in microsiemens per centimeter (µS/cm), with a very low range of 0.0 to 99.9 µS/cm, ideal for pure water.
  • Record the stable reading.

3. After Measurement

  • Rinse the electrode thoroughly with distilled or deionized water to prevent contamination.
  • Shake off excess water and replace the protective cap.
  • Turn off the tester to conserve battery life.

Maintenance

Cleaning the Electrode

Regular cleaning of the graphite electrodes is crucial for accurate measurements. If readings become erratic or slow to stabilize, clean the electrode by soaking it in a mild cleaning solution (e.g., Hanna HI7061 general purpose cleaning solution) for 15-20 minutes, then rinse thoroughly with distilled water. Never use abrasive materials to clean the electrodes.

Storage

Always store the tester with the protective cap securely in place. For long-term storage, ensure the electrode is clean and dry, and consider removing the battery to prevent leakage.

Troubleshooting

  • No Display/Unit Not Turning On: Check battery installation and ensure the battery has sufficient charge. Replace if necessary.
  • Erratic or Unstable Readings:
    • Ensure the electrode is fully submerged and free of air bubbles.
    • Clean the electrode as described in the Maintenance section.
    • Recalibrate the tester.
  • Incorrect Readings:
    • Verify that the calibration was performed correctly using a fresh standard solution.
    • Ensure the sample temperature is within the operating range of the device.

Specifications

ParameterValue
Model NumberHI98308
Measurement Range (EC)0.0 to 99.9 µS/cm
Temperature CompensationAutomatic, with exposed temperature probe
Electrode TypeGraphite
CalibrationManual, single point
Power SourceBattery Powered
Dimensions8.35 x 2.68 x 1.34 inches
Weight5.29 ounces
ColorGreen
Upper Temperature Rating50 Degrees Celsius

Warranty and Support

For specific warranty information, please refer to the documentation included with your product or contact WLR Industries directly. For technical support, product inquiries, or assistance with troubleshooting, please visit the official WLR Industries website or contact their customer service department. Contact details can typically be found on the manufacturer's packaging or website.