YOJOCK HT60

YOJOCK HT60 Gas Leak Detector User Manual

Model: HT60

1. Introduction

Welcome to the user manual for your YOJOCK HT60 Gas Leak Detector. This device is designed to provide reliable and accurate detection of various flammable gases, ensuring safety in your home, RV, caravan, or workplace. Please read this manual thoroughly before operating the device to ensure proper use and to maximize its lifespan.

YOJOCK HT60 Gas Leak Detector, a black pen-shaped device with red accents, two green and red buttons, and a digital display showing battery life and sensitivity. Two AAA batteries are shown next to it.

Figure 1: YOJOCK HT60 Gas Leak Detector with included batteries.

2. Product Features

  • Versatile Gas Detection: Detects LPG, methane, propane, natural gas, ethane, gasoline, and coal gas.
  • Rapid Response: Provides visual and audible alarms within 0.5 seconds of gas detection.
  • Dual Alarm System: Features both visual (LCD screen turns red) and audible (75dB) alerts.
  • Adjustable Sensitivity: Offers high (50-500 PPM) and low (500-1000 PPM) sensitivity modes for precise leak pinpointing or general area scanning.
  • Easy Operation: Simple setup with included AAA batteries and a quick 30-second preheating time.
  • Battery Indicator: Displays remaining battery charge on the LCD screen.
  • Automatic Shut-Off: Powers off automatically after 5 minutes of inactivity to conserve battery.
  • Compact and Portable: Pocket-sized design with a pen hook for easy carrying and storage.
  • Durable Design: Features a non-slip grip for comfortable and secure handling.
Close-up of the YOJOCK HT60 Gas Leak Detector's sensor tip, surrounded by bubbles labeled Propane, Coal Gas, Natural Gas, Ethane, Gasoline, and Methane, indicating its multi-gas detection capability. Text highlights features like <30s startup preheating, 0.5-2s response time, and high/low sensitivity modes.

Figure 2: High-precision sensors and detection capabilities.

The YOJOCK HT60 Gas Leak Detector in action, showing a red LCD display and sound waves indicating an audible alarm. Text highlights 'Audible & Visual Alarm', 'LCD Display Turns Red', and '75dB Audible Alert'.

Figure 3: Audible and visual alarm system.

3. Package Contents

Verify that all items listed below are present in your package:

  • 1 x YOJOCK HT60 Gas Leak Detector
  • 2 x AAA Batteries (included)
  • 1 x Storage Pouch
  • 1 x User Manual (available in English, German, Italian, French, and Spanish)
The contents of the YOJOCK HT60 Gas Leak Detector package, including the detector, its box, a black storage pouch, two AAA batteries, and a user manual.

Figure 4: Items included in the package.

4. Important Safety Information

  • This device is designed to detect flammable gases. It is not a substitute for proper ventilation or professional gas leak inspection.
  • Do not expose the device to extreme temperatures, high humidity, or direct sunlight.
  • Keep the device away from water and other liquids.
  • Do not attempt to disassemble or modify the device. This will void the warranty.
  • Replace batteries promptly when the low battery indicator appears to ensure accurate readings.
  • Always follow local safety regulations and guidelines when dealing with gas appliances and systems.

5. Setup

5.1 Battery Installation

  1. Locate the battery compartment cover on the back of the device.
  2. Open the cover and insert the two AAA batteries, ensuring correct polarity (+/-).
  3. Close the battery compartment cover securely.

5.2 Initial Power On

Press and hold the power button (red button) for approximately 2 seconds to turn on the device. The device will enter a preheating phase.

6. Operation

6.1 Preheating

After powering on, the detector requires approximately 30 seconds to preheat. During this time, the display may show a countdown or a warming-up indicator. Wait until the preheating is complete before proceeding with detection.

6.2 Selecting Sensitivity Mode

The HT60 offers two sensitivity modes:

  • High Sensitivity Mode: Detects gas concentrations between 50-500 PPM. Ideal for pinpointing small leaks.
  • Low Sensitivity Mode: Detects gas concentrations between 500-1000 PPM. Suitable for general area scanning.

Press the 'S' button (green button) to toggle between high and low sensitivity modes. The current mode will be indicated on the LCD display.

6.3 Gas Detection

Once preheating is complete, hold the detector with the sensor tip close to the area where a gas leak is suspected (e.g., gas pipes, appliance connections, valves).

Move the sensor tip slowly along the suspected leak path. The optimal detection distance is between 0.4 to 2.0 inches (1-5 cm) from the source.

A hand holding the YOJOCK HT60 Gas Leak Detector, pointing its sensor tip towards a gas burner on a stove, indicating a quick response time of 0.5 seconds and a detection distance of 0.4-2.0 inches.

Figure 5: Detecting a gas leak with quick response.

A four-step visual guide on how to use the YOJOCK HT60 Gas Leak Detector: Step 1 (Turn On), Step 2 (Wait for 30s preheating), Step 3 (Select Testing Mode), and Step 4 (Start Testing near a gas source).

Figure 6: Easy-to-use operation steps.

A close-up of the YOJOCK HT60 Gas Leak Detector's sensor tip near a gas stove burner, illustrating its use in a home kitchen environment.

Figure 7: Detector in use near a gas stove.

6.4 Alarm Indication

If a gas leak is detected:

  • The LCD display will turn red.
  • An audible alarm will sound. The alarm tone will increase in frequency and volume as the gas concentration rises.

In case of an alarm, immediately ventilate the area, turn off gas sources if safe to do so, and investigate the source of the leak. Do not ignore gas alarms.

6.5 Automatic Shut-Off

The device will automatically power off after 5 minutes of inactivity to conserve battery life. To restart, press and hold the power button.

7. Applications

The YOJOCK HT60 Gas Leak Detector is suitable for a variety of environments:

  • Home Kitchens: Checking gas stoves, ovens, and water heaters.
  • RV and Caravans: Inspecting propane tanks, lines, and appliances.
  • Outdoor Camping: Ensuring safety with portable gas cookers and heaters.
  • Workplaces: Detecting leaks in industrial gas lines and equipment.
A collage of four images showing different application scenarios for the gas leak detector: a woman cooking in a campervan, people camping outdoors, a kitchen with a gas stove, and industrial pipes in a workplace.

Figure 8: Various application scenarios for the detector.

A gas cylinder stored in an external compartment of an RV or campervan, illustrating a common use case for the gas leak detector.

Figure 9: Gas tank in an RV.

Multiple blue industrial gas cylinders with pressure gauges, representing a workplace or industrial application for gas leak detection.

Figure 10: Industrial gas cylinders.

A complex network of yellow and blue industrial pipes and valves, indicating the use of the gas leak detector in industrial settings.

Figure 11: Industrial piping system.

8. Maintenance

8.1 Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.

Keep the sensor tip clean and free from dust or debris to ensure accurate readings.

8.2 Battery Replacement

When the low battery indicator appears on the display, replace both AAA batteries with new ones to maintain optimal performance.

8.3 Storage

Store the device in the included storage pouch in a cool, dry place when not in use. Remove batteries if storing for extended periods.

9. Troubleshooting

IssuePossible CauseSolution
Device does not turn onDead or incorrectly installed batteriesReplace batteries with new ones, ensuring correct polarity.
Inaccurate or inconsistent readingsDirty sensor, device not fully preheated, incorrect sensitivity mode selectedClean the sensor tip, wait for the 30-second preheating to complete, adjust sensitivity mode as needed.
No alarm when gas is presentLow battery, sensor blocked, gas concentration below detection thresholdReplace batteries, ensure sensor tip is clear, check sensitivity mode.
Device turns off unexpectedlyAutomatic shut-off activated (5 minutes of inactivity), low batteryRestart the device if it was inactive, replace batteries if low.

10. Specifications

  • Model: HT60
  • Detection Gases: LPG, Methane, Propane, Natural Gas, Ethane, Gasoline, Coal Gas
  • Sensitivity: High (50-500 PPM), Low (500-1000 PPM)
  • Response Time: Approximately 0.5 seconds
  • Preheating Time: Approximately 30 seconds
  • Alarm: Visual (LCD turns red) & Audible (75dB)
  • Power Source: 2 x AAA Batteries (included)
  • Automatic Shut-off: After 5 minutes of inactivity
  • Product Dimensions (L x W x H): 16.5 x 2.1 x 2.1 cm (6.5 x 0.8 x 0.8 inches)
  • Weight: 60 grams (2.1 ounces)
  • Color: Red
  • Manufacturer: YOJOCK
  • Country of Origin: China

11. Warranty and Customer Support

YOJOCK offers 36 months of customer service and lifetime technical support for the HT60 Gas Leak Detector.

For any questions, issues, or technical assistance, please contact YOJOCK customer support through your purchase platform or refer to the contact information provided in the original packaging.

Please retain your proof of purchase for warranty claims.

© 2025 YOJOCK. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.