WLR Industries HI98121

HI98121 Hanna pH ORP Temperature Combo Water Tester - User Manual

Model: HI98121

Introduction

The HI98121 Hanna pH ORP Temperature Combo Water Tester is a reliable, waterproof device designed for quick and easy measurements of pH, Oxidation-Reduction Potential (ORP), and temperature. This accurate tester features 0.01 pH resolution, automatic two-point calibration, and temperature compensation, all integrated into a single, portable, pocket-sized unit. It eliminates the need for multiple meters, streamlining your routine water quality measurements.

What's in the Box

Upon opening the package, verify that all components are present and in good condition. The standard package includes:

Contents of the HI98121 package including the tester, cuvettes, and manuals.

Image: The HI98121 tester, cuvettes, and documentation neatly arranged within its packaging.

Product Overview

Front view of the HI98121 Hanna pH ORP Temperature Combo Water Tester, showing its display and buttons.

Image: Front view of the HI98121 tester, displaying its screen with readings and control buttons.

Another front view of the HI98121 Hanna pH ORP Temperature Combo Water Tester.

Image: A slightly different angle of the HI98121 tester, highlighting its compact design.

Close-up of the sensor end of the HI98121 tester, showing the model number HI98121.

Image: Detailed view of the sensor tip and the base of the HI98121 tester, with the model number clearly visible.

Another close-up of the sensor end of the HI98121 tester.

Image: A closer look at the sensor and electrode connection point of the HI98121.

Setup

Battery Installation

  1. Locate the battery compartment cover on the back of the device.
  2. Use a small screwdriver or coin to open the cover.
  3. Insert the battery (as specified in "What's in the Box") ensuring correct polarity.
  4. Replace the battery compartment cover and secure it tightly to maintain the waterproof seal.

Electrode Connection

The HI98121 features an integrated electrode. Ensure it is clean and properly seated before use.

Image showing the connection point for the electrode on the HI98121 tester.

Image: A visual representation of the electrode connection area on the HI98121 tester.

Operating Instructions

Turning On/Off

Taking Measurements

  1. Ensure the electrode is clean and conditioned.
  2. Immerse the electrode tip into the sample solution, ensuring the liquid level is above the sensor junction.
  3. Allow a few moments for the reading to stabilize. The display will show pH, ORP (mV), and temperature readings simultaneously.
  4. Press the MODE button to cycle through different display modes if available (e.g., showing only pH, ORP, or temperature).
  5. Press the SET/HOLD button to hold the current reading on the display. Press again to release.

Temperature Compensation

The HI98121 features automatic temperature compensation (ATC) for pH readings, ensuring accuracy across varying sample temperatures. The integrated temperature sensor automatically adjusts the pH measurement based on the sample's temperature.

Calibration

Regular calibration is crucial for maintaining the accuracy of your HI98121 tester. The device supports automatic two-point pH calibration.

pH Calibration

  1. Prepare two fresh pH buffer solutions (e.g., pH 7.01 and pH 4.01 or pH 10.01).
  2. Turn on the meter.
  3. Rinse the electrode with distilled water and blot dry.
  4. Immerse the electrode into the first pH buffer solution (e.g., pH 7.01).
  5. Press and hold the CAL button (if available, or refer to quick start guide for specific button sequence for calibration) until "CAL" appears on the display. The meter will automatically recognize the buffer.
  6. Once the first point is calibrated, rinse the electrode and immerse it into the second pH buffer solution.
  7. The meter will automatically complete the two-point calibration.
  8. Exit calibration mode (refer to quick start guide for specific button sequence).

Note: ORP calibration is typically not required for standard ORP meters as they measure relative potential. If specific ORP calibration is needed, consult the detailed instruction manual provided with the product.

Maintenance

Electrode Cleaning and Storage

Battery Replacement

When the battery indicator appears on the display, replace the battery promptly to ensure accurate readings. Follow the battery installation steps outlined in the "Setup" section.

Troubleshooting

ProblemPossible CauseSolution
No display / Meter won't turn onDead battery; Incorrect battery installationReplace battery; Check battery polarity
Unstable readingsDirty electrode; Air bubbles around sensor; Electrode not immersed deep enough; Expired buffer solutionsClean electrode; Gently tap meter to dislodge bubbles; Ensure proper immersion; Use fresh buffer solutions
Inaccurate pH readingsNeeds calibration; Electrode dry or damaged; Contaminated buffer solutionsPerform two-point calibration; Rehydrate electrode in storage solution; Use fresh buffer solutions; Replace electrode if damaged
"Err" or error message on displayCalibration error; Sensor malfunctionRepeat calibration carefully; Contact customer support if error persists

Specifications

Model NumberHI98121
BrandWLR Industries
Measurement ParameterspH, ORP (mV), Temperature
pH Resolution0.01 pH
Temperature CompensationAutomatic Temperature Compensation (ATC)
CalibrationAutomatic, Two-point pH calibration
Power SourceBattery Powered (1.5 Volts Min. Operating Voltage)
ColorGreen
Dimensions7.32 x 5.91 x 1.42 inches
Weight11.68 ounces
ManufacturerWLR Industries

Warranty and Support

For warranty information, technical support, or service inquiries, please contact WLR Industries customer service. Refer to the contact details provided in the product packaging or visit the official WLR Industries website.

This product is from a small business brand. Your support is appreciated.

For additional resources, you may visit the WLR Industries Store on Amazon.