1. Introduction
This manual provides detailed instructions for the safe and efficient operation of your OKKÖBI M12 Automatic Egg Incubator. Please read this manual thoroughly before initial use to ensure proper setup, operation, and maintenance. This incubator is designed to provide optimal conditions for hatching various types of poultry eggs.
2. Safety Instructions
- Always place the incubator on a stable, level surface away from direct sunlight, drafts, or extreme temperature fluctuations.
- Ensure the power supply matches the voltage specified on the incubator label.
- Do not immerse the incubator or its electrical components in water or any other liquid.
- Keep out of reach of children and pets.
- Unplug the incubator from the power outlet before cleaning or performing any maintenance.
- Do not operate the incubator if the power cord or plug is damaged.
- Use only original replacement parts and accessories.
3. Package Contents
Verify that all items are present in the package:
- OKKÖBI M12 Egg Incubator Unit
- Power Cable
- External Water Tank/Bottle
- Instruction Manual (this document)
4. Product Features
- Precise Temperature Control and Display: An LED control panel allows for monitoring and adjustment of temperature, with air outlets for even heat distribution.
- Automatic Humidity Control: Features a side-mounted water bottle for easy refilling without opening the lid, maintaining stable humidity.
- Automatic Egg Turner: Mimics natural hatching by rotating eggs every 120 minutes to prevent adhesion and improve hatch rates. The tray is removable for cleaning.
- 360° Easy Monitoring: A transparent lid provides a full view of the hatching process without disturbance.
- Versatile and Spacious: Accommodates 12 to 24 eggs depending on size, suitable for chicken, quail, duck, and other poultry eggs.
5. Setup
- Placement: Place the incubator on a stable, flat surface in a room with a consistent ambient temperature (ideally between 20-25°C / 68-77°F). Avoid direct sunlight or drafts.
- Connect Power: Plug the power cable into the incubator and then into a suitable electrical outlet.
- Initial Temperature Setting: The incubator will power on and display the current temperature. The default temperature for chicken eggs is typically 37.5°C (99.5°F). Adjust if necessary using the control panel buttons (see Section 6.1).
- Fill Water Tank: Fill the external water bottle with distilled or demineralized water. Connect it to the side port of the incubator. This will automatically fill the internal water channels to establish humidity.
- Pre-heat: Allow the incubator to run for at least 2-3 hours (preferably 24 hours) to stabilize the temperature and humidity before placing eggs inside.

Image: Visual guide for the initial setup and incubation process.
6. Operation
6.1. Temperature Control
The incubator features a digital LED display for temperature. Use the '+' and '-' buttons on the control panel to adjust the desired temperature. The heating indicator will illuminate when the incubator is actively heating. For most poultry, the ideal temperature is around 37.5°C (99.5°F).

Image: Detailed view of the control panel for temperature settings.
6.2. Humidity Control
The automatic humidity system uses an external water tank. Ensure the tank is always filled with distilled or demineralized water. The system will draw water as needed to maintain optimal humidity levels. This design allows for refilling without opening the incubator lid, preventing temperature and humidity fluctuations.

Image: The incubator with its external water bottle for automatic humidity maintenance.
6.3. Automatic Egg Turning
The incubator automatically rotates the eggs every 120 minutes. To activate or confirm the egg turning mode, press and hold the designated button (refer to the control panel icons). This feature is crucial for embryo development. The egg turning tray should be removed approximately 3 days before the expected hatch date to prepare for hatching.

Image: Visual explanation of the automatic egg turning mechanism.
6.4. Egg Placement and Monitoring
Gently place fertilized eggs onto the egg tray after the incubator has stabilized. The transparent lid allows for 360-degree observation of the eggs and the hatching process without disturbing the internal environment. Observe the developmental stages as shown below.

Image: Illustration of egg development stages visible through the incubator's transparent lid.
7. Incubation Guidelines
The OKKÖBI M12 incubator is suitable for various poultry eggs. Capacity and incubation times vary by egg type:
| Egg Type | Approximate Capacity | Incubation Period |
|---|---|---|
| Quail | ~25 pcs | 17-18 days |
| Pigeon | ~15 pcs | 17-19 days |
| Chicken | ~10 pcs | ~21 days |
| Duck | ~4 pcs | 27-28 days |
| Goose | ~2 pcs | 28-35 days |
Note: Capacity varies with egg size. These are general guidelines; specific conditions may vary.

Image: Visual guide for egg types and their respective incubation periods.
8. Maintenance and Cleaning
Regular cleaning ensures optimal performance and hygiene.
- Daily: Monitor water levels in the external tank and refill as needed.
- After Hatching: Unplug the incubator and allow it to cool.
- Remove the egg turning tray and wash it with mild soap and water. The tray is removable for easy cleaning.
- Wipe down the interior and exterior surfaces of the incubator with a damp cloth. Avoid getting water into electrical components.
- Ensure all parts are completely dry before reassembling or storing the incubator.
- Do not use abrasive cleaners or harsh chemicals.
9. Troubleshooting
If you encounter issues, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Temperature fluctuations | Incubator lid not sealed properly; room temperature unstable; faulty sensor. | Ensure lid is securely closed. Move incubator to a stable environment. Contact support if fluctuations persist. |
| Low humidity | Water tank empty; water channels blocked; external environment too dry. | Refill water tank. Check for blockages in water channels. Consider increasing room humidity if necessary. |
| High humidity | Too much water in channels; external environment too humid. | Ensure water tank is not overfilled. Reduce water if possible. Ensure proper ventilation in the room. |
| Eggs not turning | Egg turning function not activated; motor malfunction. | Press and hold the egg turning button to activate. If still not turning, contact support. |
| Low hatch rate | Incorrect temperature/humidity; infertile eggs; improper egg handling. | Verify temperature and humidity settings. Ensure eggs are fertile and handled correctly before incubation. |
10. Specifications
- Model: Okkobi Obi (M12)
- Product Dimensions: 10.24 x 10.24 x 5.51 inches
- Item Weight: 2.31 Pounds
- Manufacturer: OKKÖBI
- Egg Capacity: 12-24 eggs (varies by size)
- Features: Automatic Temperature Control, Automatic Humidity Control, Automatic Egg Turning, 360° Transparent View
11. Warranty and Support
Your OKKÖBI M12 Automatic Egg Incubator comes with a 5-year warranty, ensuring peace of mind for your hatching endeavors. For any questions, technical assistance, or warranty claims, our customer support team is available 24/7.


Image: Warranty information and customer support availability.
Please visit our official website or refer to the contact information provided with your purchase for direct support.