1. Product Overview

The Autoverve 520556 Power Center Supply is a replacement component designed to manage the power supply for Pentair Intellichlor and Ichlor salt cell chlorinator systems. This unit ensures the necessary power delivery for the stable operation of your pool's chlorine generator, contributing to a safe and clean swimming environment.

1.1 Compatibility

Part Number: 520556

1.2 Key Features

Autoverve 520556 Power Center Supply with included fuses

Figure 1: Autoverve 520556 Power Center Supply. This image shows the external view of the power center supply unit, along with several red automotive-style fuses.

2. Safety Information

Always prioritize safety when working with electrical components and pool equipment. Failure to follow these safety guidelines may result in electric shock, injury, or damage to equipment.

3. Installation and Setup

This section provides general guidance for installing the Autoverve 520556 Power Center Supply. Specific wiring diagrams and detailed instructions for your particular Pentair chlorinator model should be referenced from the original equipment manufacturer's manual or consulted with a professional.

3.1 Pre-Installation Checks

  1. Verify that the Autoverve 520556 Power Center Supply is the correct replacement part for your Pentair Intellichlor or Ichlor model.
  2. Inspect the unit for any visible damage that may have occurred during shipping.
  3. Ensure all necessary tools and safety equipment are available.

3.2 Mounting the Unit

  1. Select a suitable mounting location that is protected from direct sunlight and excessive moisture.
  2. The unit features mounting flanges for secure attachment to a wall or vertical surface.
  3. Use appropriate fasteners (not included) to mount the power center securely.

3.3 Electrical Connections

WARNING: Ensure power is OFF at the main breaker before proceeding.

  1. Open the protective cover of the power center.
  2. Identify the input power terminals and the output terminals for the salt cell chlorinator.
  3. Connect the main power supply wiring to the input terminals according to the original chlorinator system's wiring diagram and local electrical codes.
  4. Connect the wiring from the salt cell chlorinator to the output terminals.
  5. Ensure all connections are tight and secure.
  6. Close the protective cover.
Internal view of Autoverve 520556 Power Center Supply showing transformers, circuit boards, and connection sockets

Figure 2: Internal components of the Power Center Supply. This image highlights the transformers, circuit boards, protective covers, fuses, and connection sockets within the unit.

4. Operating Instructions

Once installed and wired correctly, the Autoverve 520556 Power Center Supply operates automatically to provide power to your salt cell chlorinator. The chlorinator's operation is controlled by its own system settings.

  1. After installation, restore power to the pool equipment at the main circuit breaker.
  2. Monitor your Pentair Intellichlor or Ichlor system to ensure it powers on and functions as expected.
  3. Refer to your chlorinator's specific manual for instructions on setting chlorine output levels and other operational parameters.
Diagram showing overcurrent, overvoltage, and overtemperature protection features of the power center

Figure 3: Circuit Protection. This diagram illustrates the built-in safety features including overcurrent, overvoltage, and overtemperature protection, represented by a shield icon.

5. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your power center supply.

Autoverve 520556 Power Center Supply with compatibility and electrical parameters

Figure 4: Parameter Configuration and Compatibility. This image displays the OEM part number 520556, power specifications (Voltage: 22-39V, Current: 3A Max), and compatibility with Pentair IntelliChlor and EasyTouch/SunTouch systems.

6. Troubleshooting

This section addresses common issues that may arise with the power center supply.

ProblemPossible CauseSolution
Chlorine generator not operating / No powerBlown fuse
Overload, short-circuit, over-voltage, over-current, or overheating
Aging or component failure
Loose wiring connection
1. Disconnect power. Check and replace any blown fuses with the correct amperage.
2. Inspect for signs of damage or corrosion.
3. Verify all electrical connections are secure.
4. If issues persist after checking fuses and connections, the unit may require replacement or professional inspection.
Unit appears damaged (e.g., bent flanges)Shipping damageMinor bends in mounting flanges can often be carefully reformed. If the unit's internal components appear compromised, contact customer support.

7. Specifications

8. Warranty and Support

Autoverve stands by the quality of its products.

Related Documents - 520556

Preview Pentair EasyTouch PL4/PSL4 Control Systems Installation Guide for Pool and Spa
This installation guide provides detailed instructions for setting up and installing the Pentair EasyTouch PL4/PSL4 Control Systems for pool and spa automation. It covers safety precautions, component overview, wiring, and system start-up.
Preview IntelliTouch® Pool and Spa Control System User's Guide
Explore the Pentair IntelliTouch® Pool and Spa Control System with this comprehensive user's guide. Learn about advanced automation, remote control capabilities, scheduling, and integration for your pool and spa. Covers system overview, operation, setup, service, maintenance, and troubleshooting.
Preview Pentair Pool and Spa Automation Systems: IntelliTouch, EasyTouch, ScreenLogic2, and More
Comprehensive guide to Pentair Water Pool and Spa's advanced automation systems, including IntelliTouch, EasyTouch, ScreenLogic2, SunTouch, and IntelliChem. Explore features, product details, and ordering information for smart pool and spa control.