1. Introduction
This manual provides detailed instructions for the safe and effective operation of your INFURIDER Handheld Anemometer 5000D. This device is designed for accurate measurement of wind speed, wind temperature, and airflow volume. Please read this manual thoroughly before use and retain it for future reference.
2. Safety Information
- Do not expose the device to extreme temperatures or direct sunlight for extended periods.
- Avoid dropping or subjecting the device to strong impacts.
- Keep the device dry. Although it is waterproof, prolonged immersion is not recommended.
- Do not attempt to disassemble or modify the device. This will void the warranty.
- Use only the provided charging cable or a compatible Type-C cable for charging.
- Keep out of reach of children.
3. Product Overview
3.1. Components

This image displays the key components of the INFURIDER Handheld Anemometer 5000D, including the fan, LCD display, control buttons, Type-C charging port, and tripod mounting port.
- Fan: Five sensitive blades for wind speed and airflow measurement.
- 2.36-inch LCD Display: Shows measurement readings, units, and battery status.
- On/Off Button: Powers the device on or off.
- MODE Button: Switches between different measurement modes (wind speed, temperature, airflow).
- MAX/MIN Button: Displays maximum, minimum, or current readings.
- UNIT Button: Changes measurement units.
- SET Button: Used for data hold and entering settings.
- Backlight Button: Activates or deactivates the LCD backlight.
- Type-C Charging Port: For recharging the internal battery.
- Tripod Mounting Port: Allows for hands-free operation with a tripod.
3.2. Key Features
- Accurate measurement of wind speed (0.3-30m/s) in 5 units (m/s, km/h, ft/min, knots, mph).
- Measures wind temperature (-10℃~45℃) in ℃/℉.
- Airflow volume test in CMM, CMS, CFM.
- User-friendly touch buttons for sensitive response and easy mode/unit switching.
- Durable, waterproof, and anti-dust design.
- Large LCD screen with backlight for clear readings in various conditions.
- Built-in 400mAh rechargeable Lithium battery with auto-off function.
- Displays MAX/MIN/CURRENT readings for wind speed and airflow volume.
- Data hold function.
- Compact and portable design (weighs 142g).
4. Setup
4.1. Battery Charging
The INFURIDER 5000D is equipped with a built-in 400mAh rechargeable Lithium battery. Before initial use, ensure the device is fully charged.
- Locate the Type-C charging port on the device.
- Connect the provided Type-C USB cable to the device and the other end to a standard USB power adapter (not included) or a computer USB port.
- The charging indicator on the display will show the charging status.
- Once fully charged, disconnect the charging cable.

This image illustrates the Type-C charging port and how to connect the charging cable to power the device.
5. Operating Instructions
5.1. Power On/Off
- To power on the device, press and hold the On/Off button for approximately 3 seconds until the display illuminates.
- To power off the device, press and hold the On/Off button for approximately 3 seconds.
- The device features an auto-off function after 5 minutes of inactivity to conserve battery. This can also be manually overridden.
5.2. Mode Selection
Press the MODE button to cycle through different measurement modes, such as wind speed, temperature, and airflow volume.
5.3. Unit Selection
Press the UNIT button to change the measurement units within the selected mode. For example, in wind speed mode, you can switch between m/s, km/h, ft/min, knots, and mph. For temperature, switch between ℃ and ℉.
5.4. Wind Speed Measurement
- Ensure the device is powered on and in wind speed measurement mode.
- Hold the anemometer so that the fan blades are directly facing the wind source.
- Read the wind speed value displayed on the LCD screen.

This image shows the anemometer being used to measure wind velocity, with a sailboat in the background, indicating its application in outdoor environments.
5.5. Airflow Volume Measurement (CFM/CMM/CMS)
- Switch to airflow volume measurement mode using the MODE button.
- Before measurement, you may need to set the area of the air duct or opening. Refer to the device's on-screen prompts or specific instructions for area input.
- Select the desired unit (CMM, CMS, or CFM) using the UNIT button.
- Position the anemometer's fan vertically with the air outlet or inlet to ensure accurate airflow measurement.
- Read the airflow volume value displayed on the LCD screen.

This image demonstrates the anemometer being used to test airflow volume within a ventilation duct, highlighting its application in HVAC systems.
5.6. Data Hold Function
To temporarily freeze the current reading on the display, briefly press the SET button. Press it again to release the hold and resume live readings.
5.7. Backlight
To activate or deactivate the LCD backlight for improved visibility in low-light conditions, press the dedicated backlight button (often indicated by a sun or lightbulb icon, or combined with the SET button by holding it for >3 seconds). The backlight ensures clear reading of wind speed, wind volume, and temperature.

This image shows the anemometer's display with its backlight feature active, making the readings visible in darker settings.
5.8. MAX/MIN/CURRENT Readings
Press the MAX/MIN button to cycle through the maximum recorded value, the minimum recorded value, and the current real-time reading for the active measurement parameter.
6. Maintenance
6.1. Cleaning
- Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Ensure the fan blades are free from dust and debris for accurate readings. Use a soft brush or compressed air if necessary.
6.2. Storage
- Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- If storing for an extended period, ensure the battery is partially charged (around 50%) to prolong its lifespan.
6.3. Battery Care
- Recharge the battery when the low battery indicator appears on the display.
- Avoid completely draining the battery frequently, as this can reduce its overall lifespan.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | Low battery; Power button not pressed correctly. | Charge the battery fully. Press and hold the On/Off button for at least 3 seconds. |
| Inaccurate readings | Fan blades obstructed; Incorrect unit selected; Device not positioned correctly. | Clean fan blades. Verify correct measurement unit. Ensure fan faces wind/airflow directly. |
| Display is dim or unreadable | Backlight off; Low battery. | Activate backlight. Charge the battery. |
| Buttons unresponsive | Temporary software glitch; Device frozen. | Try restarting the device by holding the power button. If unresponsive, allow battery to drain and recharge. |
8. Specifications
| Parameter | Value |
|---|---|
| Wind Speed Range | 0.3 - 30 m/s |
| Wind Speed Units | m/s, km/h, ft/min, knots, mph |
| Wind Temperature Range | -10℃ ~ 45℃ (14℉ ~ 113℉) |
| Airflow Volume Units | CMM (m³/min), CMS (m³/s), CFM (ft³/min) |
| Battery Type | 400mAh Rechargeable Lithium Ion |
| Auto-Off | 5 minutes (adjustable/manual off supported) |
| Product Dimensions | 9.09 x 3.07 x 2.99 inches (23.1 x 7.8 x 7.6 cm) |
| Item Weight | 142 Grams (5.01 ounces) |
| Material | Acrylonitrile Butadiene Styrene (ABS) |
9. Warranty and Support
No specific warranty duration is provided in the product information. For warranty claims, technical assistance, or any questions regarding your INFURIDER Handheld Anemometer 5000D, please contact INFURIDER customer service directly. Refer to the product packaging or the official INFURIDER website for the most current contact details and support information.