Spa Luxe 2246BN

Spa Luxe 2246BN Medi Spa Exam Chair and Treatment Bed User Manual

Model: 2246BN

Introduction

This manual provides essential information for the safe and effective use, maintenance, and troubleshooting of your Spa Luxe 2246BN Medi Spa Exam Chair and Treatment Bed. Please read this manual thoroughly before operating the chair and retain it for future reference.

Spa Luxe 2246BN Medi Spa Exam Chair in White

Image: The Spa Luxe 2246BN Medi Spa Exam Chair and Treatment Bed in white, shown in a partially reclined position.

Safety Information

Always prioritize safety during operation and maintenance. Failure to follow safety guidelines may result in injury or damage to the equipment.

  • Ensure the chair is placed on a stable, level surface.
  • Do not exceed the maximum weight capacity of 440 lbs.
  • Keep hands and feet clear of moving parts during adjustments.
  • Regularly inspect all cables and connections for damage.
  • Utilize the emergency stop switch immediately if an unexpected movement occurs or if there is a risk of entrapment.

Setup

Unpacking and Placement

Carefully unpack all components. It is recommended that two or more people assist with the initial placement due to the chair's weight and size. Position the chair in its intended location, ensuring adequate space for full rotation and height adjustments.

Dimensions

  • Product Length: 70 inches (standard length)
  • Product Width: 24 inches (standard width), extends to 33 inches with removable armrests.
  • Height Range: 19 inches to 32 inches from the ground.
  • Seat Width: 24 inches.
  • Footrest Length: 15 inches (extendable).
  • Base Dimensions: 41 inches long, 21 inches wide at the narrowest point, and 27 inches wide at the widest point.
Diagram showing Spa Luxe 2246BN chair dimensions, rotation, and maximum loading capacity

Image: A diagram illustrating the chair's original position, 240-degree rotation capability, and a maximum loading capacity of 200kg (440 lbs).

Power Connection

Connect the power cord to a grounded electrical outlet. Ensure the power switch on the chair is in the 'On' position.

Operating Instructions

The Spa Luxe 2246BN features four motors for precise adjustments and a 240-degree rotational base.

Control Panels

The chair is equipped with rocker switches located at the back of the chair and at the base for controlling the four motors. Memory functions are exclusively located on the back control panel.

Close-up of the back control panel on the Spa Luxe 2246BN chair

Image: A close-up view of the back control panel, showing buttons for memory settings (M1, M2), reset (R), lock, and various chair adjustments.

Close-up of the base control panel on the Spa Luxe 2246BN chair

Image: A close-up view of the base control panel, showing buttons for various chair adjustments and the reset function.

Adjusting Chair Position

  • Height Adjustment: Use the appropriate rocker switches to raise or lower the chair. The chair can adjust from 19 inches to 34 inches in height. Raising the seat from lowest to highest takes approximately 28 seconds.
  • Backrest Adjustment: Adjust the backrest angle using the dedicated controls.
  • Footrest Adjustment: Adjust the footrest angle and extension. Raising the footrest from fully vertical to fully up takes approximately 18 seconds.
  • Trendelenburg Capability: The chair supports Trendelenburg positioning, where the body is laid flat on the back with the feet higher than the head.
  • Vertical Seated Position: The chair can achieve an almost fully vertical seated position, offering greater flexibility compared to models limited to 80 degrees.

Rotation

The chair offers a total of 240 degrees of rotation (120 degrees in either direction). To rotate the chair, unlock the rotational mechanism located at the base. Once the desired position is achieved, lock the mechanism back into place to secure the chair.

Close-up of the rotation lock mechanism on the Spa Luxe 2246BN chair base

Image: A close-up view of the rotational clutch mechanism, which is hidden by a plastic housing for a clean aesthetic. The lever is used to unlock and lock the chair's rotation.

Diagram illustrating the 240-degree rotation of the Spa Luxe 2246BN chair

Image: A top-down diagram showing the chair's rotary movement, indicating a range of -120° to +120°, totaling 240 degrees of rotation.

Memory and Reset Functions

The back control panel includes memory settings (M1, M2) and a one-button reset function. These allow for quick recall of preferred positions and a return to a default state.

Optional Controls

An optional hand remote and foot controls are available for enhanced operational convenience. When using the hand remote, memory functions and the one-button reset can be controlled directly from the remote.

Close-up of the optional hand remote for the Spa Luxe 2246BN chair

Image: A close-up of the optional hand remote, displaying buttons for various chair adjustments, memory settings (M1, M2), lock, set, power, and reset functions.

Close-up of the optional foot controls for the Spa Luxe 2246BN chair

Image: A close-up of the optional foot controls, showing multiple pedals for hands-free adjustment of the chair's various movements.

LED Lighting System

The chair features a customizable colorful base LED lighting system for aesthetic enhancement.

Close-up of the base of the Spa Luxe 2246BN chair showing LED lighting

Image: A close-up of the chair's base, highlighting the integrated LED lighting system that can display various colors.

Product Video Overview

Video: An overview of the Spa Luxe 2246BN Medical Treatment Chair with Rotation, demonstrating its features and functionality.

Maintenance

Cleaning

The chair's upholstery is made of durable Polyurethane (PU). To clean, simply wipe with a dry cloth. Avoid harsh chemicals or abrasive cleaners that may damage the material.

General Care

Regularly inspect the chair for any loose parts, unusual noises, or signs of wear. Ensure all moving parts operate smoothly. If any issues are detected, refer to the troubleshooting section or contact customer support.

Troubleshooting

Chair Stops Moving Unexpectedly

  • Safety Sensor Activation: The chair is equipped with safety sensors at the back that detect obstructions and halt backward movement. Check for any objects behind the chair.
  • Emergency Stop Switch: If the chair stops abruptly, check if the emergency stop switch has been pressed. To reset, twist the red button to the right until it pops out.
Close-up of the safety sensor on the Spa Luxe 2246BN chair

Image: A close-up of the safety sensor located at the back of the chair, designed to detect obstructions and prevent backward movement.

Close-up of the emergency stop switch on the Spa Luxe 2246BN chair

Image: A close-up of the red emergency stop switch, which immediately halts all chair movement when pressed.

Other Issues

For any other operational issues not covered here, please consult the support section for contact information.

Specifications

FeatureDetail
Model2246BN
BrandSpa Luxe
Product Dimensions (L x W x H)70" x 24" (33" with armrests) x 19"-32"
Base Dimensions (L x W)41" x 21" (narrowest) / 27" (widest)
Weight Capacity440 lbs
Rotational Range240° (120° in either direction)
Motors4
Upholstery MaterialPolyurethane (PU)
Frame MaterialAlloy Steel
ADA CompliantYes
Trendelenburg CapabilityYes
ControlsIntegrated Rocker Switches (back & base), Optional Hand Remote, Optional Foot Controls
Special FeaturesMemory Functions, One-Button Reset, Lock Function, Safety Sensors, Emergency Stop Switch, Customizable Colorful Base LED Lighting System, Fully Adjustable Headrest, Removable and Reversible Armrests
Seat Raise Time (Low to High)28 seconds
Footrest Raise Time (Vertical to Up)18 seconds

Warranty Information

The Spa Luxe 2246BN Medi Spa Exam Chair and Treatment Bed comes with a 2-year warranty covering motors and electronics. For detailed warranty terms and conditions, please refer to your purchase documentation or contact Spa Luxe customer support.

Customer Support

For technical assistance, parts, or warranty claims, please contact Spa Luxe customer support. Please have your model number (2246BN) and purchase date available when contacting support.

Contact Information:

  • Refer to your product packaging or purchase invoice for the most current contact details.
  • Visit the official Spa Luxe website for support resources and contact options.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.