1. Introduction
The KHIRY RP5D-630 Automatic Transfer Switch (ATS) is designed to automatically switch between a normal power source and a reserve power source. This ensures continuous power supply to critical loads in industrial and commercial applications. It integrates switching and logic control functions into a single unit, providing reliable and safe power transfer.
This manual provides essential information for the safe installation, operation, and maintenance of the RP5D-630 ATS. Please read this manual thoroughly before installation or operation.
2. Important Safety Information
WARNING: Electrical shock hazard. Installation and maintenance must be performed by qualified and authorized personnel only. Failure to follow these instructions can result in serious injury or death.
- Always disconnect all power sources before working on the switch. Verify that all circuits are de-energized using appropriate testing equipment.
- Ensure proper grounding of the equipment.
- Adhere to all local and national electrical codes and regulations.
- Do not operate the switch if it appears damaged or malfunctioning.
- Use appropriate personal protective equipment (PPE) when working with electrical systems.
3. Product Features
The RP5D-630 ATS offers a range of features designed for reliable power management:
- Full-Automatic Operation: Automatically transfers load between normal and reserve power sources.
- Compulsory "0" Position: Allows for manual isolation of both power sources for maintenance or emergencies.
- Generator Integration: Capable of sending a start signal to a generator when the normal power fails.
- Protection Functions: Includes examination and protection against lack of phase, under/over voltage, and frequency deviations.
- Delay Regulation: Adjustable time delays for transfer operations.
- Electric Mechanism Interlock: Ensures safe and proper switching sequence.

Figure 3.1: Main view of the KHIRY RP5D-630 Automatic Transfer Switch. This image displays the overall structure of the switch, including the main power terminals and the control unit on the right side.
4. Setup and Installation
Installation of the RP5D-630 ATS must be performed by a qualified electrician in accordance with all applicable electrical codes.
4.1 Mounting
Mount the ATS in a suitable enclosure that provides adequate ventilation and protection from environmental factors. Ensure the mounting surface is stable and capable of supporting the weight of the switch.
4.2 Wiring Connections
Connect the normal power source, reserve power source, and load according to the wiring diagram provided with the product and local electrical standards. Ensure all connections are secure and properly torqued.
- Normal Power Input: Connect the primary power source to the designated terminals.
- Reserve Power Input: Connect the secondary (e.g., generator) power source to the designated terminals.
- Load Output: Connect the electrical load to the output terminals of the ATS.
- Grounding: Ensure the switch is properly grounded.

Figure 4.1: View of the KHIRY RP5D-630 ATS terminals. This image highlights the connection points for the normal power, reserve power, and load, labeled for clarity.
5. Operating Instructions
5.1 Automatic Operation
Once installed and powered, the RP5D-630 ATS operates automatically. It continuously monitors the normal power source. If the normal power fails or falls outside acceptable parameters, the switch will initiate a transfer sequence:
- Normal power failure detected.
- After a pre-set delay, the switch sends a start signal to the reserve power source (e.g., generator).
- Once the reserve power source is stable, the ATS transfers the load from normal power to reserve power.
- When normal power is restored and stable, the ATS waits for a pre-set stabilization delay.
- The ATS transfers the load back to the normal power source.
- After another pre-set delay, the ATS sends a stop signal to the reserve power source.
5.2 Compulsory "0" Function
For maintenance or emergency situations requiring complete isolation of both power sources from the load, use the compulsory "0" function:
- Locate the "Compulsory 0" self-lock button on the control panel.
- Press and hold the button. The switch will move to the "0" position, disconnecting both normal and reserve power from the load.
- The switch will remain in this position until manually reset or power conditions change, depending on the specific configuration.

Figure 5.1: Control panel of the KHIRY RP5D-630 ATS. This image shows the interface with indicators and control buttons, including the selector switch and the compulsory '0' button.
6. Maintenance
Regular maintenance ensures the longevity and reliable operation of the RP5D-630 ATS. All maintenance procedures must be performed by qualified personnel with power disconnected.
- Periodic Inspection: Visually inspect the switch for any signs of damage, loose connections, or overheating (discoloration).
- Cleaning: Keep the switch and its enclosure clean and free from dust, dirt, and moisture. Use a dry, lint-free cloth. Do not use solvents.
- Connection Checks: Periodically check the tightness of all electrical connections.
- Functional Testing: Conduct periodic functional tests to ensure the automatic transfer mechanism operates correctly.
7. Troubleshooting
This section provides guidance for common issues. For complex problems, contact a qualified technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Switch does not transfer automatically. | No power detected from either source; control circuit issue; incorrect settings. | Verify power to both sources; check control wiring; review settings. |
| Load not receiving power. | Both power sources are off; switch in "0" position; tripped breaker. | Check power sources; ensure switch is not in "0"; reset breakers. |
| Generator does not start. | No start signal from ATS; generator fault; fuel issue. | Verify ATS control wiring to generator; check generator status and fuel. |
8. Technical Specifications
The following are the key technical specifications for the KHIRY RP5D-630 Automatic Transfer Switch:
| Parameter | Value |
|---|---|
| Model | RP5D-630 |
| Rated Current | 630A |
| Rated Insulating Voltage | Up to 690V |
| Rated Operating Voltage | 380V |
| Rated Frequency | 50Hz/60Hz |
| Application Environment | Industrial and commercial distribution equipment (e.g., hospitals, banks, high buildings, telecommunications) |

Figure 8.1: Side view of the KHIRY RP5D-630 ATS. This image provides a different perspective of the switch, potentially showing mounting points or additional labels.
9. Warranty and Support
This KHIRY product is manufactured to high-quality standards. For information regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact your supplier.
For technical support, troubleshooting assistance, or spare parts inquiries, please contact KHIRY customer service or your authorized distributor. Provide your product model number (RP5D-630) and purchase details when seeking support.