IVEM3024

Felicity Solar IVEM3024 3KVA 24V Solar Inverter

User Manual

1. Introduction and Overview

The Felicity Solar IVEM3024 is a versatile 3KVA 24V solar inverter designed to provide reliable power for various applications. It integrates a pure sine wave inverter with a high-efficiency MPPT solar charge controller, ensuring optimal energy conversion and stable power output. This device is engineered for seamless compatibility with mains voltage, generator power, and solar energy sources, offering flexible power supply transitions. Its intuitive LCD display allows users to easily monitor system status and customize operational settings, including battery charging current and AC/solar charger priority. The IVEM3024 is an ideal solution for enhancing energy management, providing a stable and sustainable power infrastructure.

Felicity Solar IVEM3024 3KVA 24V Solar Inverter front view

Figure 1: Front view of the Felicity Solar IVEM3024 Inverter.

2. Safety Instructions

Please read and understand all safety instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Qualified Personnel: Installation and maintenance should only be performed by qualified personnel.
  • High Voltage: The inverter operates at high voltages. Do not open the unit or attempt repairs unless specifically instructed.
  • Proper Grounding: Ensure the inverter is properly grounded to prevent electric shock.
  • Ventilation: Install the inverter in a well-ventilated area to prevent overheating. Maintain adequate clearance around the unit.
  • Battery Safety: Work with batteries carefully. Wear eye protection and avoid contact with battery acid. Ensure proper battery polarity.
  • Emergency Shutdown: Know how to quickly disconnect all power sources (AC, DC, solar) to the inverter in an emergency.
  • Environmental Conditions: Do not expose the inverter to rain, snow, liquids, or excessive dust.

3. Product Features

The Felicity Solar IVEM3024 inverter offers a range of advanced features for efficient and reliable power management:

  • Built-in MPPT solar charge controller for optimized solar energy harvesting.
  • Intuitive LCD display for easy adjustment of settings and system monitoring.
  • Versatile compatibility with mains, generator, and solar power sources.
  • Reliable performance with features like auto-restart during AC recovery and cold start capability.
  • Support for lithium battery activation.
  • Scalable design: Up to 12 units can be connected in parallel for a total power output of 5KVA.
  • AC coupling compatibility for seamless integration with existing solar setups.

4. Package Contents

Upon unpacking, please verify that all items listed below are present and undamaged:

  • Felicity Solar IVEM3024 Inverter Unit
  • User Manual
  • Communication Cable (if applicable)
  • Mounting Hardware (screws, wall anchors)
  • Warranty Card (if applicable)

If any items are missing or damaged, please contact your supplier immediately.

5. Setup and Installation

Proper installation is crucial for the safe and efficient operation of the inverter. It is highly recommended that installation be performed by a certified electrician or solar professional.

  1. Site Selection: Choose a location that is dry, well-ventilated, and protected from direct sunlight, rain, and excessive dust. Ensure the ambient temperature is within the specified operating range.
  2. Mounting: Securely mount the inverter to a sturdy vertical surface using the provided mounting hardware. Ensure there is sufficient clearance (at least 20 cm) around all sides for proper airflow.
  3. Wiring Connections:
    • Battery Connection: Connect the battery bank to the inverter's DC input terminals, observing correct polarity (+ to + and - to -). Ensure battery voltage matches the inverter's 24V requirement.
    • AC Input Connection: Connect the AC mains or generator power source to the inverter's AC input terminals.
    • AC Output Connection: Connect your loads (appliances, distribution board) to the inverter's AC output terminals.
    • PV Input Connection: Connect the solar panel array to the inverter's PV input terminals, ensuring the PV voltage does not exceed 500V. Observe correct polarity.
    • Grounding: Connect the inverter's ground terminal to a reliable earth ground.
  4. Initial Power-Up: After all connections are secure and verified, switch on the battery breaker first, then the AC input breaker (if applicable), and finally the PV input breaker. The inverter will initiate its startup sequence.
Felicity Solar IVEM3024 installation diagram and multiple units

Figure 2: Example installation diagram and multiple inverter units.

6. Operating Instructions

The IVEM3024 inverter features an LCD display and control buttons for easy operation and setting adjustments.

  • LCD Display: The LCD displays real-time system information such as input voltage, output voltage, battery status, charging current, and error codes.
  • Navigation Buttons: Use the buttons (typically 'Up', 'Down', 'Enter', 'Esc') to navigate through menus and adjust settings.
  • Setting Customization: Access the settings menu to customize parameters such as:
    • Battery charging current (e.g., for different battery capacities).
    • AC/solar charger priority (e.g., Solar First, Utility First, SBU Priority).
    • Output voltage and frequency.
    • Battery type (e.g., AGM, Flooded, Lithium).
  • Cold Start Function: The inverter can be started directly from the battery without AC input, useful in off-grid scenarios.
  • Auto-Restart: The inverter will automatically restart when AC power is restored after a power outage.
  • Parallel Operation: For increased power capacity, up to 12 units of the IVEM3024 can be connected in parallel. Refer to the detailed parallel kit manual for specific wiring and configuration instructions.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Periodically clean the inverter's exterior with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Connection Check: Annually, or as needed, inspect all electrical connections (AC, DC, PV, ground) for tightness and corrosion. Tighten any loose connections.
  • Ventilation: Ensure the area around the inverter remains clear and well-ventilated to prevent overheating.
  • Battery Inspection: Regularly check battery terminals for corrosion and ensure proper electrolyte levels for flooded batteries.

8. Troubleshooting

This section provides solutions to common issues you might encounter. For problems not listed here, please contact technical support.

ProblemPossible CauseSolution
Inverter not turning onNo battery connection, low battery voltage, DC breaker off.Check battery connections, charge battery, turn on DC breaker.
No AC outputOverload, short circuit, AC output breaker off, inverter fault.Reduce load, check for short circuits, turn on AC breaker, check LCD for error codes.
Battery not chargingPV input issue, AC input issue, charge controller fault, incorrect settings.Check PV connections, ensure AC input is present, verify charging settings on LCD.
Error code on LCDSpecific system fault (e.g., over-temperature, over-voltage).Refer to the inverter's detailed error code list in the full manual or contact support.

9. Specifications

Key technical specifications for the Felicity Solar IVEM3024 Inverter:

SpecificationValue
ManufacturerFelicity Solar
Product Dimensions30 x 13 x 40 cm
Item Weight10.8 kg
Model NumberIVEM3024
Voltage24 Volts
ColorWhite
First Available Date18 December 2023

10. Warranty and Support

The Felicity Solar IVEM3024 Inverter comes with a warranty period of 90 days from the date of purchase. This warranty covers defects in materials and workmanship under normal use.

For technical support, warranty claims, or service inquiries, please contact your original point of purchase or the authorized Felicity Solar service center. Please have your product model number (IVEM3024) and purchase date available when contacting support.

Related Documents - IVEM3024

Preview Felicitysolar IVEM Series Solar Inverter User Guide (3KVA-5KVA)
Comprehensive user guide for Felicitysolar IVEM Series solar inverters (IVEM3024, IVEM5048). Learn about installation, operation, safety, and features of these MPPT solar chargers and hybrid inverters for reliable power solutions.
Preview Посібник користувача: Сонячний інвертор Felicitysolar IVEM Серії (3KBA-5KBA)
Посібник користувача для сонячних інверторів Felicitysolar IVEM Серії (3KBA-5KBA). Охоплює встановлення, експлуатацію, безпеку, усунення несправностей та технічні характеристики.
Preview Felicitysolar IVEM3024 3KVA Off-grid Solar Inverter Datasheet
Datasheet for the Felicitysolar IVEM3024 3KVA off-grid high-frequency solar inverter, detailing its features, system configuration, and technical specifications for efficient solar energy management.
Preview Solar Inverter IVEM3024/5048: Features and Specifications
Detailed information on the Felicitysolar IVEM3024/5048 solar inverter, including features like configurable input voltage, battery charging, AC/Solar priority, and technical specifications for both models.