1. Introduction
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Adviace FB-RFB241 Furnace Draft Inducer Blower Motor. This unit is designed as a replacement part for various Rheem and Ruud furnace models, ensuring proper exhaust gas ventilation for efficient and safe furnace operation.
2. Safety Information
WARNING: Before attempting any installation or maintenance, ensure the main power supply to the furnace is disconnected. Failure to do so can result in electrical shock, personal injury, or death. Installation should only be performed by a qualified technician. Always wear appropriate personal protective equipment (PPE) such as gloves and eye protection.
- Disconnect all electrical power to the furnace before servicing.
- Verify that the replacement part matches the specifications of the original unit.
- Ensure all connections are secure and properly insulated.
- Do not operate the furnace if any part is damaged or improperly installed.
3. Compatibility
The Adviace FB-RFB241 Draft Inducer Blower Motor is a direct replacement for the following furnace models and part numbers:
- Compatible Furnace Models:
- Rheem Criterion II
- Ruud Silhouette II
- Rheem RGPH-07EAUER
- Rheem RGPH-12EARJR
- Replaces Part Numbers:
- Rheem: 70-24157-03, 70-101087-81, 70-101087-01, FB-RFB241, 70-24175-01, 70-24178-01, 702415703, 70581406
- Jakel: J238-150-1533, J238-150-15165, 117847-00, 117847-07
- Fasco: 7121-11559, A066, 712111559, 70582635
- Ametek: 117104-01, 117104-04
- Packard: 66781

Image: Adviace FB-RFB241 installed in a furnace, demonstrating compatibility.
4. Technical Specifications
| Specification | Value |
|---|---|
| Voltage | 120 Volts |
| Hertz | 60 Hz |
| Full Load Amperage | 1.71 Amps |
| RPM | 3000 RPM |
| Horsepower | 60 Watts |
| Insulation Class | B |
| Rotation | Counterclockwise Lead End |
| Material | Metal (Cast Aluminum Housing) |
| Item Weight | 7.68 pounds |
| Package Dimensions | 12 x 11.8 x 8.9 inches |

Image: Technical specifications label on the motor.
5. Package Contents
The Adviace FB-RFB241 Furnace Draft Inducer Blower Motor assembly includes:
- 1x Furnace Draft Inducer Blower Motor (complete assembly with motor, housing, felt, and blower wheel)

Image: Complete Adviace FB-RFB241 assembly.
6. Installation Instructions
This section provides general guidelines for replacing your furnace draft inducer blower motor. Always refer to your furnace manufacturer's specific instructions and safety warnings. Professional installation is highly recommended.
- Disconnect Power: Turn off the main power supply to your furnace at the circuit breaker or fuse box. Verify power is off using a voltage tester.
- Access the Old Motor: Locate the existing draft inducer blower motor on your furnace. It is typically connected to the exhaust vent system.
- Disconnect Wiring and Hoses: Carefully disconnect all electrical wiring and any vacuum hoses attached to the old motor. Note their positions for reinstallation.
- Remove Old Motor: Unbolt or unscrew the old draft inducer motor from the furnace housing. Remove the old unit.
- Prepare New Motor: The Adviace FB-RFB241 comes with a durable cast aluminum housing and a thick felt gasket. This gasket ensures a tight seal and reduces metal-on-metal contact, contributing to quieter operation.
- Install New Motor: Position the new Adviace FB-RFB241 motor in place, aligning the mounting holes. Secure it with the appropriate bolts or screws.
- Reconnect Wiring and Hoses: Reconnect all electrical wiring and vacuum hoses to the new motor, ensuring all connections are secure.
- Restore Power and Test: Restore power to the furnace. Initiate a heating cycle to test the new draft inducer motor. Observe for proper operation and listen for any unusual noises. The new unit is designed for quiet and smooth operation.

Image: Upgraded cast aluminum housing for enhanced durability.

Image: Sound dampening felt seal for quiet operation.
Installation Overview Video
Video: An overview of the Adviace FB-RFB241 Furnace Draft Inducer Blower Motor, demonstrating its features and components relevant to installation.
7. Operation
The draft inducer blower motor is a critical component in your furnace's combustion system. Its primary function is to draw combustion gases from the heat exchanger and expel them through the exhaust vent. This creates a negative pressure within the combustion chamber, allowing fresh air to be drawn in for proper fuel ignition and efficient burning. The motor operates automatically when the furnace calls for heat, ensuring safe and effective removal of exhaust byproducts.

Image: Features of the Adviace FB-RFB241 motor, ensuring reliable operation.
8. Maintenance
To ensure the longevity and optimal performance of your Adviace draft inducer blower motor, consider the following maintenance tips:
- Annual Inspection: Have a qualified HVAC technician inspect your furnace annually, including the draft inducer motor, for any signs of wear or damage.
- Keep Clear: Ensure the area around the motor and exhaust vent is free from obstructions, dust, and debris.
- Listen for Changes: Pay attention to any changes in the motor's sound during operation. Unusual noises may indicate a developing issue. The Adviace motor is designed to be very quiet.

Image: The Adviace motor provides quiet operation.
9. Troubleshooting
If you experience issues with your furnace related to the draft inducer motor, consult this basic troubleshooting guide. For complex problems, contact a qualified HVAC technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Motor does not start or hums loudly but doesn't spin. | Seized bearings, electrical issue, or obstruction. | Check for obstructions. Verify electrical connections. If the motor is seized, replacement is necessary. (Refer to the installation video for an example of a seized old motor). |
| Unusual noises (grinding, squealing). | Worn bearings, loose components, or debris. | Inspect for debris. If noises persist, the motor may need replacement. The Adviace motor is designed for quiet operation. |
| Furnace not igniting. | Draft inducer not creating sufficient draft. | Ensure the motor is running correctly and the exhaust path is clear. Check pressure switch operation. |
10. Warranty and Support
The Adviace FB-RFB241 Furnace Draft Inducer Blower Motor comes with a 1-Year Warranty, assuring quality and reliability. For technical assistance, warranty claims, or further inquiries, please contact Adviace customer support through your purchase platform or the official Adviace website.