1. Introduction
The RESKIU 2400W 24V Hybrid Solar Inverter is a multifunctional inverter/charger designed to provide reliable and uninterrupted power. It integrates the functions of a power inverter, solar charger, and battery charger. This unit is suitable for various applications, including home, office, camping, and RV environments, supporting a wide range of electrical appliances.

Figure 1: Front view of the RESKIU 2400W 24V Hybrid Solar Inverter, showing the main unit with its LCD display.
Key features of this hybrid solar inverter include:
- Pure sine wave output, compatible with mains or generator power.
- Built-in 50A MPPT solar charge controller.
- Configurable AC/solar charger priority via LCD settings.
- Real-time LCD display for monitoring operational status.
- Comprehensive safety protections including overload, over-temperature, and short-circuit protection.
- Automatic restart function.
- Smart battery charging capabilities.

Figure 2: Overview of key features including utility grid compatibility, home appliance support, MPPT solar charge controller, solar input, AC input, auto restart, overload protection, short circuit protection, smart battery charger, and pure sine wave output.
2. Safety Information
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.
- Installation must be performed by qualified personnel.
- Ensure proper grounding of the unit.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Avoid exposing the inverter to rain, snow, spray, or any liquids.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Disconnect all power sources (solar, battery, AC) before performing any maintenance or wiring.
- This inverter provides protection against overload, over-temperature, and short circuits. However, proper system design is crucial for safe operation.
3. Product Overview
3.1 Physical Components

Figure 3: Labeled diagram of the RESKIU 2400W 24V Hybrid Solar Inverter, showing front, side, and bottom views with numbered components.
- Charging indicator: Indicates the charging status.
- LCD display: Shows real-time operational data and settings.
- Fault indicator: Illuminates to indicate a system fault.
- Function buttons: Used for navigating menus and adjusting settings.
- Status indicator: Shows the current operational status of the inverter.
- AC output: Connection terminals for AC loads.
- Battery positive: Positive terminal for battery connection.
- Battery negative: Negative terminal for battery connection.
- Safety (earth) ground: Grounding terminal for safety.
- Input breaker: Circuit breaker for AC input.
- AC input: Connection terminals for utility grid or generator AC input.
- ON/OFF: Power switch for the unit.
- COM: Communication port.
3.2 LCD Display

Figure 4: Detailed view of the LCD display, showing various icons and indicators for system status.
- PV input: Indicates solar panel input status.
- AC input: Indicates utility grid or generator AC input status.
- Input voltage, input frequency, PV voltage, battery voltage, charger current: Displays various input and charging parameters.
- Setting programs: Indicates the current setting program.
- Flashing with warning code: Indicates a warning or fault condition with a specific code.
- Output voltage, output frequency, load percent, load in VA, load in watt and discharging current: Displays various output and load parameters.
- Load level: Visual indicator of the current load percentage.
- DC/AC inverter circuit is working: Indicates the inverter function is active.
- Battery level: Visual indicator of the battery charge level.
- Utility charger circuit is working: Indicates the AC charger function is active.
- Unit connects to the PV panel: Indicates solar panel connection.
- Unit connects to the mains: Indicates utility grid connection.
- Load is supplied by utility power: Indicates the load is being powered by the utility grid (bypass mode).
- Unit alarm is disabled: Indicates the audible alarm is turned off.
- Overload: Indicates an overload condition.
4. Setup and Installation
Proper installation is critical for the safe and efficient operation of your hybrid solar inverter. Refer to the wiring diagram below for connection guidance. Always ensure all power sources are disconnected before making any electrical connections.

Figure 5: System connection diagram illustrating how the inverter connects to solar panels, battery, utility grid, and household loads.
4.1 Mounting the Inverter
- Choose a dry, well-ventilated area, away from direct sunlight and heat sources.
- Mount the inverter vertically on a sturdy surface.
- Ensure sufficient clearance around the unit for proper airflow (at least 20 cm on all sides).
4.2 Wiring Connections
- Battery Connection: Connect the battery bank to the "Battery positive" and "Battery negative" terminals. Ensure correct polarity. Use appropriate gauge wiring for the current draw.
- Solar Panel Connection: Connect the solar array to the PV input terminals. Observe correct polarity and ensure the PV voltage is within the inverter's specified range.
- AC Input Connection: Connect the utility grid or generator AC supply to the "AC input" terminals.
- AC Output Connection: Connect your AC loads (e.g., household appliances) to the "AC output" terminals.
- Grounding: Connect the "Safety (earth) ground" terminal to a reliable earth ground.
Note: All wiring should comply with local electrical codes and regulations. Consult a qualified electrician if you are unsure about any part of the installation process.
5. Operating Instructions
5.1 Powering On/Off
- To Power On: After all connections are secure, switch on the battery breaker (if applicable), then the solar array breaker (if applicable), and finally the AC input breaker. Press the "ON/OFF" button on the inverter.
- To Power Off: First, disconnect all AC loads. Then, switch off the AC input breaker, followed by the solar array breaker, and finally the battery breaker. Press and hold the "ON/OFF" button on the inverter until it shuts down.
5.2 LCD Display and Settings
The LCD display provides real-time information about the inverter's operation. Use the function buttons to navigate through the display screens and adjust settings. Refer to Section 3.2 for a detailed explanation of the LCD icons and indicators.
Key configurable settings typically include:
- AC input voltage range (e.g., for PC or home appliances).
- Charger priority (Solar first, Utility first, Solar and Utility).
- Output source priority (Utility first, Solar first, SBU - Solar, Battery, Utility).
- Battery type and charging parameters.
- Alarm settings.
Consult the detailed settings menu in the full product manual for specific parameter adjustments.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your RESKIU Hybrid Solar Inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Connections: Annually check all electrical connections for tightness and signs of corrosion. Loose connections can cause overheating and damage.
- Battery Inspection: If using lead-acid batteries, check electrolyte levels and terminal condition as per battery manufacturer guidelines.
- Environment: Ensure the operating environment remains within specified temperature and humidity ranges.
Always power off the inverter and disconnect all power sources before performing any maintenance.
7. Troubleshooting
This section provides solutions to common issues you might encounter. For more complex problems, contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter does not power on. | No battery connection, low battery voltage, power switch off. | Check battery connections and voltage. Ensure the ON/OFF switch is pressed. |
| No AC output. | Overload, short circuit, over-temperature, battery low, AC input not present. | Reduce load. Check for short circuits. Allow unit to cool. Charge battery. Check AC input connection. |
| Charging indicator not lit. | No solar input, no AC input, battery full, charging disabled. | Check solar panel connections and sunlight. Check AC input. Verify battery status and charging settings. |
| Fault indicator is lit. | Internal fault, severe overload, high temperature. | Note the warning code on the LCD. Power off the unit, wait a few minutes, then restart. If the fault persists, contact support. |
8. Specifications
| Parameter | Value |
|---|---|
| Rated Power | 2400W |
| Surge Power | 6000VA |
| DC Input Voltage | 24V |
| AC Output Voltage | 230VAC |
| Frequency Range | 50Hz |
| Voltage Waveform | Pure Sine Wave |
| Efficiency | 93% |
| Transfer Time (PC) | 10 ms |
| Transfer Time (Home Appliances) | 20 ms |
| Operating Temperature | 0°C to 55°C |
| Storage Temperature | -15°C to 60°C |
| Humidity | 5% to 95% relative humidity (non-condensing) |
| Product Dimensions | 305*272*100mm / 460*295*115mm |
| Item Weight | 5.2KG |
| Brand | RESKIU |
| Model Name | 2400W 24v Hybrid |
| Power Source | Solar Powered |
Note: Some specifications may vary slightly. Refer to the product label for the most accurate information.
9. Warranty and Support
For warranty information and technical support, please refer to the documentation included with your purchase or contact the seller directly. Protection plans may be available for extended coverage.
- Manufacturer: AMMLAN
- Brand: RESKIU
- ASIN: B0CN32D71P
- Model Number: 50d087f8-cb88-48dd-8d3c-8e24eb6ce955
Please have your model number and ASIN ready when contacting support.