STIGMA P802-1-RCA

STIGMA Wireless Tattoo Battery User Manual

Model: P802-1-RCA

Introduction

This manual provides comprehensive instructions for the safe and effective operation of your STIGMA Wireless Tattoo Battery. Designed for portability and convenience, this 1400mAh lithium battery power supply is compatible with RCA tattoo guns and machine pens, featuring an LED digital display for precise voltage control. Please read this manual thoroughly before first use to ensure optimal performance and longevity of your device.

Safety Information

  • Do not expose the device to extreme temperatures, direct sunlight, or high humidity.
  • Keep the device away from water and other liquids.
  • Use only the recommended charging cable and power adapter.
  • Do not attempt to disassemble or modify the device. This will void the warranty and may cause damage.
  • Store the device in a cool, dry place when not in use.
  • Keep out of reach of children.

Product Overview

The STIGMA Wireless Tattoo Battery is a compact and efficient power solution for your tattoo machine. It features an RCA jack for universal compatibility, intuitive controls, and a clear LED display for voltage indication.

STIGMA Wireless Tattoo Battery

Figure 1: Front view of the STIGMA Wireless Tattoo Battery, showing the LED display and control buttons.

RCA Interface and Type-C Charging Port

Figure 2: Close-up view of the RCA interface for connecting to tattoo machines and the Type-C fast charging port.

Key Features:

  • Wireless Operation: Provides freedom of movement without cables.
  • 1400mAh Battery Capacity: Offers 3-5 hours of working time on a full charge.
  • RCA Compatibility: Universal design fits most RCA tattoo machines.
  • LED Digital Display: Clear indication of voltage levels (5V-11V) via colored lights.
  • Type-C Charging: Convenient and fast charging.
  • Lightweight Design: Weighs only 53g for comfortable handling.

Setup

  1. Charge the Battery: Before first use, fully charge the battery using the provided Type-C cable and a compatible power adapter. Refer to the "Charging" section for details.
  2. Connect to Tattoo Machine: Insert the RCA jack of the wireless battery into the RCA port of your tattoo machine. Ensure a secure connection.
Battery features: 1400mAh capacity, 3-5 hours work time, 2 hours charging, Type-C

Figure 3: Illustration of battery specifications including capacity, working hours, and charging time.

Operating Instructions

The STIGMA Wireless Tattoo Battery features a simple and intuitive control interface.

Power On/Off:

  • To turn on the device, press and hold the power button (lotus icon) for 3 seconds. The LED display will illuminate.
  • To turn off the device, press and hold the power button for 3 seconds. The LED display will turn off.
  • To pause or restart operation during use, short press the power button.

Voltage Adjustment:

  • Use the "+" button to increase the voltage.
  • Use the "-" button to decrease the voltage.
  • Voltage can be adjusted in 0.5V increments within the range of 5V to 11V.
  • The LED digital display indicates the current voltage level through different colors. Refer to the table below for voltage-color correspondence.
Voltage control with 13 levels from 5V to 11V, indicated by colored LEDs

Figure 4: Visual representation of voltage levels and their corresponding LED colors.

Voltage-Color Correspondence Table:

Voltage (V)LED Color
5.0VBlue
5.5VLight Blue
6.0VCyan
6.5VLight Green
7.0VGreen
7.5VDark Green
8.0VYellow-Green
8.5VYellow
9.0VGold
9.5VOrange
10.0VDark Orange
10.5VRed
11.0VDark Red

Note: It is recommended to operate the battery at 5-8V to prolong its life and the life of the tattoo machine.

Official Product Video:

Video: STIGMA New wireless tattoo battery pack. This video demonstrates the features and basic operation of the wireless tattoo battery, including connection to a machine and control functions.

Charging

The STIGMA Wireless Tattoo Battery is equipped with a Type-C charging interface for convenient and efficient charging.

  • Connect the provided Type-C charging cable to the charging port on the battery.
  • Connect the other end of the cable to a compatible USB power adapter (not included) or a USB port on a computer.
  • A full charge typically takes approximately 2 hours.
  • The LED display may indicate charging status (e.g., blinking lights, specific color). Refer to the device's visual cues for charging completion.
Type-C Charging illustration

Figure 5: Illustration showing the Type-C charging port and cable connection.

Maintenance

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any power source before cleaning.
  • Storage: When not in use for extended periods, store the battery in a cool, dry place. It is advisable to charge the battery to about 50% before long-term storage to preserve battery health.
  • Battery Care: Avoid fully discharging the battery frequently. Recharge it when the power is low to extend its lifespan.

Troubleshooting

ProblemPossible CauseSolution
Device does not turn on.Battery is depleted.
Power button not held long enough.
Charge the battery fully.
Press and hold the power button for 3 seconds.
Voltage cannot be adjusted.Device is off or paused.Ensure the device is powered on and not paused.
Short battery life.Battery not fully charged.
Operating at high voltage.
Battery degradation over time.
Ensure full charge before use.
Try operating at 5-8V.
Battery lifespan is finite; consider replacement if severe.
Device cuts in and out.Loose RCA connection.Ensure the RCA connection is secure and firm.

Specifications

FeatureDetail
ModelP802-1-RCA
Battery Capacity1400mAh Lithium Battery
Working Hours3-5 hours (depending on usage)
Charging TimeApprox. 2 hours
Voltage Output5V - 11V (13 adjustable levels in 0.5V increments)
InterfaceRCA Jack
Charging PortType-C
Weight53g (approx. 2.82 ounces)
Dimensions3.62 x 2.87 x 1.54 inches (Package Dimensions)
ManufacturerSolong

Warranty and Support

For warranty information or technical support, please contact STIGMA customer service through the retailer where the product was purchased or visit the official STIGMA website. Please retain your proof of purchase for warranty claims.

Note: Unauthorized disassembly or modification of the device will void the warranty.

© 2024 STIGMA. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.