EZA G3 2600W

EZA Energie Zen Alternative Logo

EZA Connect 2600W Rooftop Air Conditioner User Manual

Model: G3 2600W

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your EZA Connect 2600W Rooftop Air Conditioner. Please read this manual thoroughly before installation and use, and retain it for future reference.

The EZA Connect 2600W is designed to provide comfortable cooling and heating for recreational vehicles, caravans, and motorhomes. It features a powerful heat pump and utilizes R32 refrigerant for enhanced energy efficiency and environmental responsibility.

EZA Connect 2600W Rooftop Air Conditioner Unit

Image 1.1: The EZA Connect 2600W Rooftop Air Conditioner unit, showing its compact and streamlined design.

2. Safety Information

WARNING: Failure to follow these safety instructions could result in fire, electric shock, or personal injury.

  • Installation must be performed by a qualified technician in accordance with all local and national electrical and building codes.
  • Ensure the power supply is disconnected before any installation, maintenance, or repair work.
  • Do not operate the unit with damaged wiring or if it is not functioning correctly.
  • Keep children and pets away from the unit during operation and maintenance.
  • Do not block the air inlets or outlets of the unit.
  • Use only genuine EZA replacement parts and accessories.

3. Product Features

  • Cooling and Heating Functionality: Reversible heat pump for year-round climate control.
  • Energy Efficient: Utilizes R32 refrigerant for improved energy performance and reduced environmental impact.
  • Quiet Operation: Engineered for low noise levels, ensuring a comfortable environment.
  • Slim Diffuser: Extra-flat 'slim' air diffuser with two outlets for optimized airflow distribution.
  • Integrated Controls: Touch control panel on the diffuser with LED ambient lighting and temperature display.
  • Remote Control: Full-function remote control for convenient adjustment of settings.
  • Smart Control: Remote control via smartphone or tablet application.
  • Adjustable Airflow: Airflow adjustable from 130 to 330 m³/h.
  • Temperature Range: Calibrated temperature range from 16°C to 30°C.
R32 Refrigerant Logo

Image 3.1: The R32 refrigerant logo, indicating the use of an environmentally friendly and efficient refrigerant.

4. Setup and Installation

The EZA Connect 2600W is designed for rooftop installation on recreational vehicles. Proper installation is crucial for the unit's performance and safety. It is strongly recommended that installation be carried out by a certified professional.

4.1. Installation Requirements

  • Mounting Opening: A roof opening of 40 x 40 cm is required for installation.
  • Roof Thickness: Ensure the roof structure can support the weight of the unit and is within the manufacturer's specified thickness range.
  • Electrical Supply: A dedicated electrical circuit with appropriate voltage and amperage is necessary. Refer to the specifications section for power requirements.
  • Clearance: Ensure adequate clearance around the unit on the rooftop for proper airflow and maintenance access.

4.2. Installation Steps (Overview)

  1. Prepare the roof opening according to the specified dimensions.
  2. Secure the outdoor unit to the roof using appropriate fasteners and sealing materials to prevent water ingress.
  3. Install the indoor diffuser unit, ensuring it aligns correctly with the outdoor unit.
  4. Connect the electrical wiring according to the wiring diagram provided in the full installation guide (not included in this manual).
  5. Test the unit for proper operation, including cooling, heating, and fan functions.

For detailed installation instructions, consult the comprehensive installation guide provided with your unit or contact a qualified EZA service technician.

5. Operating Instructions

The EZA Connect 2600W can be operated using the included remote control, the touch control panel on the indoor diffuser, or via a smartphone/tablet application.

5.1. Remote Control Operation

EZA Air Conditioner Remote Control

Image 5.1: The remote control for the EZA Connect 2600W air conditioner, showing its display and buttons.

The remote control allows for comprehensive control of the unit's functions:

  • Power Button: Turns the unit ON/OFF.
  • MODE Button: Cycles through operating modes (Cool, Heat, Fan, Dry, Auto).
  • Temperature Buttons (+/-): Adjusts the desired temperature setting (16°C to 30°C).
  • FAN Button: Adjusts fan speed (Low, Medium, High, Auto).
  • MENU/SET Buttons: Accesses and confirms advanced settings.
  • LED Button: Controls the ambient LED lighting on the diffuser.
  • TURBO Button: Activates maximum cooling or heating for rapid temperature change.
  • Timer Function: Set the unit to turn ON or OFF automatically after a specified period.

5.2. Touch Control Panel

The indoor diffuser features a touch control panel for basic operations and a display for current temperature and settings. Refer to the unit's display for visual feedback.

5.3. Smartphone/Tablet Control

Download the dedicated EZA Connect application from your device's app store. Follow the in-app instructions to pair your device with the air conditioner for remote control functionality.

6. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your EZA Connect 2600W air conditioner.

6.1. Air Filter Cleaning

The air filters should be cleaned regularly, typically every 2-4 weeks, depending on usage and environmental conditions.

  1. Turn off the air conditioner and disconnect power.
  2. Open the front panel of the indoor diffuser.
  3. Remove the air filters.
  4. Clean the filters with a vacuum cleaner or wash them with lukewarm water and mild detergent. Allow them to dry completely before reinstallation.
  5. Reinstall the dry filters and close the front panel.

6.2. Exterior Cleaning

Wipe the exterior surfaces of both the indoor and outdoor units with a soft, damp cloth. Do not use harsh chemicals, abrasive cleaners, or solvents.

6.3. Professional Inspection

It is recommended to have the unit inspected by a qualified technician annually to check refrigerant levels, electrical connections, and overall system health.

7. Troubleshooting

Before contacting customer support, refer to the following common issues and solutions:

ProblemPossible CauseSolution
Unit does not turn onNo power supply; Remote control batteries depleted; Circuit breaker trippedCheck power connection; Replace remote batteries; Reset circuit breaker
Insufficient cooling/heatingDirty air filters; Blocked air vents; Incorrect temperature setting; Doors/windows openClean air filters; Clear obstructions; Adjust temperature; Close all openings
Unusual noiseLoose components; Debris in fan; Unit not levelInspect for loose parts; Remove debris; Ensure unit is level (professional check recommended)
Water leakageBlocked drain hose; Improper installationClear drain hose; Contact a professional for inspection

If the problem persists after attempting these solutions, please contact EZA customer support or a qualified service technician.

8. Specifications

FeatureSpecification
BrandEZA
ModelG3 2600W
Cooling Capacity2600 W (8870 Btu/h)
Heating Capacity2400 W (8190 Btu/h)
RefrigerantR32
Seasonal Energy Efficiency (SEER)2.35
Seasonal Coefficient of Performance (SCOP)2.25
Cold Consumption (Watt/Ampere)1196 W / 5.2 A
Hot Consumption (Watt/Ampere)1035 W / 4.5 A
Peak Start Current20 A / 0.5 sec
Operating Temperature Range (Hot)-5°C to +24°C
Operating Temperature Range (Cold)+18°C to +46°C
Sound Level (dBA)42 - 53
Airflow (min/max)130 - 330 m³/h
DiffuserExtra-slim, 2 outlets
LightingAmbient LED
ColorWhite
Mounting Opening40 x 40 cm
Adjustable Temperature Interval16°C to 30°C
Installation TypeRooftop
Control MethodTouch, Remote, Smartphone/Tablet
Power SourceCorded Electric

9. Warranty and Support

For warranty information, please refer to the warranty card included with your product or visit the official EZA website. Keep your proof of purchase for warranty claims.

If you require technical assistance, spare parts, or have questions not covered in this manual, please contact EZA customer support through their official channels. Provide your product model (G3 2600W) and serial number when seeking support.

© 2023 EZA. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.