1. Introduction
The GuliTech VICTOR/RuoShui VC890C+ is a stable digital multimeter featuring a 28mm LCD display and battery operation. This device is designed for measuring various electrical parameters including DC Voltage (DCV), AC Voltage (ACV), DC Current (DCA), AC Current (ACA), Resistance, Capacitance, Frequency, Diode, and Transistor (hFE). It also includes a continuity test function, auto power-off, and backlight for enhanced usability. Built around an integrated circuit, this multimeter serves as a reliable tool for laboratory work, factory maintenance, electronics enthusiasts, and general household use.
2. Unpacking and Contents
Upon opening the product box, please verify that all items listed below are present and undamaged:
- VC890C+ Digital Multimeter Unit
- 1.5V AA LR6 Battery (2 pieces)
- User Manual (1 piece)
- Test Leads (1 pair)
If any items are missing or damaged, please contact your supplier immediately.
3. Safety Information
This meter complies with IEC61010 safety standards. To ensure safe operation and prevent electric shock or damage to the meter, please read and adhere to the following safety guidelines carefully:
- Do not exceed the specified input limits for any range.
- Voltages below 36V DC or 25V AC are generally considered safe. When measuring voltages above these levels, always ensure test lead connections are correct and insulation is intact to avoid electric shock. A high voltage warning symbol will display when input exceeds 24V AC or DC.
- Always remove the test leads from the circuit before changing the function or range setting on the rotary switch.
- Select the correct function and range for your measurement to prevent operational errors. While the meter includes protective functions across its ranges, careful operation is essential for safety.
- Do not operate the meter if the battery compartment cover or the back cover is not securely fixed.
- Never apply voltage when measuring resistance, capacitance, diode, or performing a continuity test.
- Before replacing batteries or fuses, disconnect the test leads from any test points and turn off the meter.
4. Product Features
The VC890C+ Digital Multimeter offers a range of features for versatile electrical testing:
- Large 28mm LCD display for clear readings.
- Automatic power-off function to conserve battery life.
- Backlight for visibility in low-light conditions.
- Diode and Continuity test with audible buzzer.
- Low battery indication.
- Function protection for enhanced durability.
- 200mA/20A protection for current measurements.
- True RMS measurement capability.
- NCV (Non-Contact Voltage) measurement.
- Integrated torch function.
- Shock-proof protection for rugged use.
- Measures DCV, ACV, DCA, ACA, resistance, capacitance, frequency, diode, and transistor (hFE).
5. Setup
5.1. Battery Installation
- Ensure the multimeter is turned off and disconnect any test leads.
- Locate the battery compartment on the back of the meter.
- Unscrew the retaining screw(s) and remove the battery cover.
- Insert two 1.5V AA LR6 batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
- Replace the battery cover and secure it with the screw(s).
5.2. Connecting Test Leads
Always connect the test leads correctly for accurate and safe measurements.
- Insert the black test lead into the "COM" (Common) jack.
- For most voltage, resistance, frequency, capacitance, diode, and continuity measurements, insert the red test lead into the "VΩHzF" jack.
- For current measurements up to 200mA, insert the red test lead into the "mA" jack.
- For high current measurements (up to 20A), insert the red test lead into the "20A" jack.

Figure 1: Front view of the VC890C+ Digital Multimeter with test leads connected to the COM and VΩHzF jacks.
6. Operating Instructions
To operate the multimeter, turn the rotary switch to the desired measurement function. Ensure test leads are connected to the correct input jacks for the selected function.
6.1. DC Voltage (DCV) Measurement
- Set the rotary switch to the desired DCV range (e.g., 200mV, 2V, 20V, 200V, 1000V).
- Connect the red test lead to the "VΩHzF" jack and the black test lead to the "COM" jack.
- Connect the test probes across the DC voltage source or component to be measured.
6.2. AC Voltage (ACV) Measurement
- Set the rotary switch to the desired ACV range (e.g., 2V, 20V, 200V, 750V).
- Connect the red test lead to the "VΩHzF" jack and the black test lead to the "COM" jack.
- Connect the test probes across the AC voltage source or component to be measured.
6.3. DC Current (DCA) Measurement
- Set the rotary switch to the desired DCA range (e.g., 200mA, 20A).
- For currents up to 200mA, connect the red test lead to the "mA" jack. For currents up to 20A, connect the red test lead to the "20A" jack. Connect the black test lead to the "COM" jack.
- Open the circuit where current is to be measured and connect the multimeter in series with the circuit.
6.4. AC Current (ACA) Measurement
- Set the rotary switch to the desired ACA range (e.g., 200mA, 20A).
- For currents up to 200mA, connect the red test lead to the "mA" jack. For currents up to 20A, connect the red test lead to the "20A" jack. Connect the black test lead to the "COM" jack.
- Open the circuit where current is to be measured and connect the multimeter in series with the circuit.
6.5. Resistance (Ω) Measurement
- Set the rotary switch to the desired Resistance range (e.g., 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ).
- Connect the red test lead to the "VΩHzF" jack and the black test lead to the "COM" jack.
- Ensure the circuit or component is de-energized before measuring resistance. Connect the test probes across the component.
6.6. Capacitance (F) Measurement
- Set the rotary switch to the Capacitance (F) range.
- Connect the red test lead to the "VΩHzF" jack and the black test lead to the "COM" jack.
- Ensure the capacitor is fully discharged before measurement. Connect the test probes across the capacitor.
6.7. Frequency (Hz) Measurement
- Set the rotary switch to the Frequency (Hz) range.
- Connect the red test lead to the "VΩHzF" jack and the black test lead to the "COM" jack.
- Connect the test probes across the signal source to measure its frequency.
6.8. Diode Test
- Set the rotary switch to the Diode symbol.
- Connect the red test lead to the "VΩHzF" jack and the black test lead to the "COM" jack.
- Connect the red probe to the anode and the black probe to the cathode of the diode. The forward voltage drop will be displayed. Reverse the probes; an open circuit (OL) should be displayed.
6.9. Transistor (hFE) Test
- Set the rotary switch to the hFE position.
- Insert the transistor's emitter, base, and collector leads into the corresponding holes in the hFE socket on the meter, ensuring correct NPN or PNP type selection. The hFE value will be displayed.
6.10. Continuity Test
- Set the rotary switch to the Continuity symbol.
- Connect the red test lead to the "VΩHzF" jack and the black test lead to the "COM" jack.
- Connect the test probes across the circuit or component. If resistance is below approximately 50Ω, the buzzer will sound, indicating continuity.
6.11. NCV (Non-Contact Voltage) Measurement
The NCV function allows for non-contact detection of AC voltage, useful for identifying live wires without direct contact.
- Set the rotary switch to the NCV position.
- Bring the top part of the meter close to the AC voltage source (e.g., a wall outlet or insulated wire).
- The NCV induction voltage range is 48-220V. As the meter approaches the detected point, the AC voltage intensity is indicated by the red indicator light flashing and the buzzer beeping at an increasing rate.

Figure 2: NCV Non-Contact Voltage Measurement in progress, showing the meter detecting AC voltage near a power outlet.
6.12. Temperature Measurement
The multimeter can measure temperature using a K-type thermocouple (not included, typically sold separately).
- Set the rotary switch to the Temperature (°C/°F) position.
- Connect the K-type thermocouple to the appropriate input jacks (usually the VΩHzF and COM jacks, observing polarity).
- Place the thermocouple probe at the point where temperature is to be measured. The temperature will be displayed in Celsius or Fahrenheit.

Figure 3: Temperature measurement using the VC890C+ Multimeter, showing a probe in water and the display indicating 71°C.
6.13. Data Hold Function
Press the "HOLD" button to freeze the current reading on the display. Press it again to release the hold and resume live readings.
6.14. Backlight and Flashlight
The meter features a backlight for the display and a built-in flashlight for illuminating the work area. Refer to the specific button on the meter for activating these functions.
7. Maintenance
7.1. Cleaning
Wipe the meter's casing with a damp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before use.
7.2. Battery Replacement
When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate readings. Follow the battery installation steps in Section 5.1.
7.3. Fuse Replacement
If the current measurement function fails, the fuse may need replacement. Refer to the safety notes in Section 3 before attempting fuse replacement. Typically, fuses are located inside the meter and require opening the back cover. Use only fuses of the specified type and rating.
8. Troubleshooting
If you encounter issues with your VC890C+ multimeter, consider the following common troubleshooting steps:
- No Display or Faint Display: Check battery charge. Replace batteries if low. Ensure batteries are installed with correct polarity.
- Incorrect Readings: Verify that the rotary switch is set to the correct function and range. Ensure test leads are securely connected to the correct input jacks. Check if the circuit or component being measured is de-energized (for resistance, capacitance, diode tests).
- No Continuity Beep: Ensure the meter is in continuity test mode. Check if the circuit has high resistance or is open.
- Current Measurement Failure: Check the fuse. Replace if blown (refer to Section 7.3). Ensure test leads are connected to the correct current input jacks (mA or 20A).
- Meter Does Not Turn On: Check battery installation and charge. Ensure the rotary switch is moved from the OFF position.
If problems persist after attempting these steps, contact customer support.
9. Specifications
Below are the general specifications for the GuliTech VICTOR/RuoShui VC890C+ Digital Multimeter:

Figure 4: Physical dimensions of the VC890C+ Digital Multimeter.
| Specification | Value |
|---|---|
| Brand | GuliTech |
| Model Number | G-VC890C+ |
| Power Source | Battery Powered (2 x 1.5V AA LR6) |
| Display | 28mm LCD, 2000 Counts |
| Style | Clamp meter/multimeter |
| Item Weight | 0.5 Kilograms |
| Upper Temperature Rating | 50 Degrees Celsius |
| Item Dimensions (L x W x H) | 22 x 15 x 12 Centimeters (Packaging) |
| Meter Dimensions (H x W x D) | 178mm x 86mm x 52mm (Approximate) |
| Specification Met | EMC, ISO 9001, RoHS |
| Manufacturer | Victor |
| Included Components | VC890C+ Multimeter |
10. Warranty and Support
Specific warranty details for the GuliTech VICTOR/RuoShui VC890C+ Digital Multimeter are not provided in this manual. For warranty information, technical support, or service inquiries, please refer to the product packaging or contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase for any warranty claims.