1. Introduction
Thank you for choosing the Wellmet DS-CRYS106 Black Rectangle Crystal Chandelier. This manual provides essential information for the safe installation, operation, and maintenance of your new lighting fixture. Please read these instructions thoroughly before beginning installation and retain them for future reference.

Image 1.1: The Wellmet DS-CRYS106 Black Rectangle Crystal Chandelier, showcasing its illuminated crystal tiers.
2. Safety Information
WARNING: To avoid the risk of fire, electric shock, or personal injury, always follow these safety precautions:
- Always turn off the main power supply at the circuit breaker before installing, cleaning, or servicing the fixture.
- Consult a qualified electrician if you are not familiar with electrical wiring.
- Ensure all electrical connections comply with local codes and ordinances.
- Use only the specified bulb type and wattage (E12 base, max 60W per bulb, 16 bulbs total).
- Do not exceed the maximum wattage.
- Handle crystal components with care to prevent breakage.
- This fixture is designed for indoor use only.
- Ensure the mounting surface can support the weight of the fixture (approximately 75 pounds).
3. Package Contents
Carefully unpack the box and ensure all components are present and undamaged. If any parts are missing or broken, contact Wellmet customer service before proceeding with installation.
- Chandelier Frame
- Mounting Hardware (canopy, mounting plate, screws, wire nuts)
- Adjustable Hanging Chains
- Crystal Strips (various sizes, pre-assembled or requiring attachment)
- Installation Instructions (this manual)

Image 3.1: Dimensional diagram of the chandelier, indicating its length, width, height, and chain length.
4. Specifications
| Feature | Specification |
|---|---|
| Model Number | DS-CRYS106 |
| Dimensions (L x W x H) | 43.3" x 21.5" x 21.5" (Chandelier body) |
| Adjustable Hanging Height | Up to 71.3" (including chain) |
| Weight | Approximately 75 lbs |
| Material | Crystal, Glass, Metal Steel |
| Color | Black frame, Clear crystals |
| Bulb Base | E12 |
| Number of Lights | 16 |
| Max Wattage per Bulb | 60W (Bulbs not included) |
| Voltage | 110 Volts |
| Installation Type | Ceiling Mounting, Hardwired |
| Indoor/Outdoor Usage | Indoor Only |
5. Setup and Installation
Professional installation by a qualified electrician is highly recommended.
- Turn off Power: Locate the circuit breaker controlling the light fixture and turn off the power. Verify power is off using a voltage tester.
- Prepare Mounting: Attach the mounting plate to the junction box in the ceiling using the provided screws. Ensure the junction box is securely mounted and can support the fixture's weight.
- Adjust Hanging Height: Determine the desired hanging height. Adjust the length of the chains by removing links as needed. Attach the chains to the chandelier frame and the canopy.
- Wire Connections: Carefully connect the fixture's wires to the house wires:
- Connect the black wire (live) from the fixture to the black wire from the junction box.
- Connect the white wire (neutral) from the fixture to the white wire from the junction box.
- Connect the ground wire (bare copper or green) from the fixture to the ground wire from the junction box.
- Mount Canopy: Carefully push the wired canopy up to the ceiling, aligning the screws on the mounting plate with the holes in the canopy. Secure the canopy with the decorative nuts or screws.
- Install Bulbs: Screw 16 E12 base bulbs (not included, max 60W each) into the sockets. Do not overtighten.
- Attach Crystals: If the crystal strips are not pre-assembled, carefully attach them to the chandelier frame according to the included diagram. Handle crystals by their edges to avoid fingerprints.

Image 5.1: The chandelier installed in a dining area, demonstrating its placement and scale.
6. Operating Instructions
After successful installation and with power restored, the chandelier can be operated via a standard wall switch. This fixture is compatible with dimmer switches (sold separately) if you wish to adjust the light intensity. The control method is listed as "App" and "Push Button" in some specifications, which may refer to compatible smart home systems or external controllers not included with the basic fixture. For standard operation, use a wall switch.

Image 6.1: Visual representation of the chandelier with lights on and off, highlighting the crystal's appearance in both states.
7. Maintenance
Regular maintenance will help preserve the appearance and functionality of your chandelier.
- Cleaning: Turn off power before cleaning. Dust the fixture regularly with a soft, dry cloth. For crystal components, use a soft, lint-free cloth dampened with a mild glass cleaner. Avoid abrasive cleaners or solvents that could damage the finish or crystals.
- Bulb Replacement: Ensure power is off and bulbs have cooled before replacing. Unscrew the old bulb and screw in a new E12 base bulb of the correct wattage (max 60W).
- Inspection: Periodically check all connections and hanging components for security.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on |
|
|
| Flickering lights |
|
|
| Chandelier hangs unevenly |
|
|
If you encounter issues not listed here or if troubleshooting steps do not resolve the problem, please contact Wellmet customer support.
9. Warranty and Support
This Wellmet chandelier comes with a Limited Warranty. Please refer to the warranty documentation included with your purchase for specific terms and conditions. For technical support, replacement parts, or warranty claims, please contact Wellmet customer service.
Manufacturer: Wellmet
Contact Information: Please visit the official Wellmet website or refer to your purchase documentation for the most current customer support contact details.