Sloan EBV-138-A

Sloan EBV-138-A Single Flush Water Closet Sensor Assembly Instruction Manual

Introduction

This instruction manual provides essential information for the proper installation, operation, maintenance, and troubleshooting of the Sloan EBV-138-A Single Flush Water Closet Cover, Ring, and Sensor Assembly. Please read this manual thoroughly before proceeding with any procedures to ensure correct usage and to maintain product longevity.

Product Overview

The Sloan EBV-138-A is a single flush water closet cover, ring, and sensor assembly designed for use with Sloan G2 and ECOS sensor flushometers. This assembly supports both 1.28 GPF (Gallons Per Flush) and 1.6 GPF flush volumes. It features an engineered metal cover with a replaceable lens window, providing a complete replacement solution for compatible units.

Sloan EBV-138-A Single Flush Water Closet Sensor Assembly

Image: The Sloan EBV-138-A Single Flush Water Closet Sensor Assembly.

Diagram illustrating the internal components of a Sloan ECOS & G2 flushometer with the sensor assembly

Image: Diagram showing the components of a Sloan ECOS & G2 flushometer, including the override button assembly, electronic module, lens window, G2 cover, vacuum breaker, and control stop.

Key Features

  • Infrared Sensor: Equipped with a multiple-focused infrared sensor featuring lobular sensing fields for accurate detection of both high and low targets. This design ensures reliable and efficient flushing operation.
  • Compatibility: Specifically designed for seamless integration with Sloan G2 and ECOS sensor water closet flushometers.
  • Flush Volume Support: Compatible with both 1.28 GPF and 1.6 GPF flushometer settings.
  • Durable Construction: Features an engineered metal cover with a replaceable lens window for long-term performance.

Compatibility Check

This assembly is specifically designed to work as a replacement part for Sloan G2 and ECOS flushometers. It is crucial to verify your existing flushometer model number to ensure proper fit and function. Using incompatible parts may lead to improper operation or damage to the unit.

Genuine Sloan Parts

To ensure optimal performance, reliability, and to extend the life of your Sloan products, it is highly recommended to use only Sloan Genuine Parts. These parts are manufactured and tested to Sloan's precise specifications, specifically designed for the most reliable commercial restroom products. Utilizing genuine parts helps prevent premature wear, reduces the need for frequent repairs, and protects your investment.

Assortment of Sloan flushometer replacement parts, including rings, gaskets, and internal components

Image: An assortment of Sloan flushometer replacement parts, emphasizing the importance of genuine components.

Setup and Installation

Installation of the EBV-138-A assembly involves replacing an existing cover, ring, and sensor unit on a compatible Sloan G2 or ECOS flushometer. Due to the integration of plumbing and electronic components, professional installation by a qualified plumber is strongly recommended to ensure correct setup and prevent potential issues.

General Installation Steps:

  1. Turn Off Water Supply: Locate the main water shut-off valve for the flushometer or the entire facility and turn it off completely. Flush the toilet to relieve any remaining water pressure.
  2. Remove Existing Assembly: Carefully remove the existing cover and sensor assembly from the flushometer. This may involve unscrewing retaining nuts or clips.
  3. Disconnect Wiring: Disconnect any electrical wiring or sensor connections from the old assembly. Note the orientation and connection points for reassembly.
  4. Install New Assembly: Position the new EBV-138-A cover, ring, and sensor assembly onto the flushometer. Ensure all components are correctly aligned.
  5. Connect Wiring: Reconnect the electrical wiring and sensor connections securely.
  6. Secure Assembly: Fasten the new assembly in place using the appropriate retaining nuts or clips, ensuring a snug fit without overtightening.
  7. Restore Water Supply: Slowly turn the water supply back on and check for any leaks around the flushometer connections.
  8. Test Operation: Test the flushometer's operation to ensure it functions correctly.

Note: These are general steps. Always refer to the specific installation guide provided with your Sloan G2 or ECOS flushometer for detailed, model-specific instructions.

Detailed cutaway view of a Sloan flushometer, showing internal mechanisms and water flow

Image: A detailed cutaway view of a Sloan flushometer, illustrating its internal mechanisms.

Operating Instructions

Once the Sloan EBV-138-A sensor assembly is correctly installed, it enables hands-free operation of your water closet flushometer. The infrared sensor detects user presence and initiates a flush cycle after the user departs.

Sensor Operation:

  • Detection: The sensor will detect your presence when you approach the fixture.
  • Automatic Flush: Upon departure from the sensor's detection zone, the sensor will activate the flushometer, initiating a flush.
  • Manual Override (if applicable): If your flushometer model is equipped with a manual override button, it can be pressed to initiate a flush at any time, regardless of sensor detection.

Maintenance

Regular maintenance helps ensure the optimal performance and longevity of your Sloan EBV-138-A sensor assembly and flushometer.

  • Cleaning the Sensor Lens: Periodically clean the sensor lens window to ensure proper operation. Use a soft, damp cloth and a mild, non-abrasive soap. Avoid harsh chemicals, abrasive cleaners, or scouring pads, as these can damage the lens or sensor components.
  • Leak Inspection: Regularly inspect all connections around the flushometer for any signs of leaks. Address any leaks promptly to prevent water waste and potential damage to the surrounding area.
  • Battery Replacement: If your specific flushometer model requires batteries for the sensor assembly (the EBV-138-A requires 4 AA batteries for operation, though they are not included with this assembly), monitor their charge level. Replace batteries as needed, following the instructions in your flushometer's manual, to ensure continuous and reliable operation.
  • Obstruction Check: Ensure that there are no objects obstructing the sensor's field of view, as this can interfere with proper detection and flushing.

Troubleshooting

This section addresses common issues you might encounter with your Sloan EBV-138-A sensor assembly and flushometer.

IssuePossible CauseSolution
Flushometer does not flush automatically.
  • Obstructed or dirty sensor lens.
  • Low or dead batteries (if applicable).
  • Water supply turned off or restricted.
  • Improper sensor alignment or connection.
  • Clean the sensor lens with a soft, damp cloth.
  • Replace batteries if necessary (4 AA batteries required for operation).
  • Ensure the water supply valve to the flushometer is fully open.
  • Verify the sensor assembly is correctly installed and all connections are secure.
Continuous flushing or dripping.
  • Internal flushometer component issue (e.g., worn diaphragm).
  • Debris in the flushometer valve.
  • Turn off the water supply to the flushometer immediately.
  • This typically indicates an issue with the flushometer's internal mechanism, not the sensor assembly itself. Consult a qualified plumber for inspection and repair.
Weak or incomplete flush.
  • Insufficient water pressure.
  • Partially closed water supply valve.
  • Blockage in the flushometer or toilet bowl.
  • Ensure the water supply valve is fully open.
  • Check the building's water pressure.
  • Inspect for any visible blockages. Professional assessment may be required.

Specifications

SpecificationDetail
ManufacturerSloan
Part NumberEBV-138-A
Item Weight2.37 pounds
Product Dimensions7.9 x 6.9 x 4.25 inches
CompatibilitySloan G2 & ECOS Sensor Water Closet Flushometers (1.28 GPF and 1.6 GPF)
Sensor TypeMultiple-focused infrared
Power Requirement4 AA batteries (not included with this assembly)
Date First AvailableAugust 23, 2023

Warranty and Support

For detailed warranty information, technical support, or further assistance regarding your Sloan EBV-138-A Single Flush Water Closet Sensor Assembly, please refer to the official Sloan website or contact Sloan customer service directly. When seeking support, always provide your product model number (EBV-138-A) to facilitate efficient service.

You can visit the Sloan website for product documentation, FAQs, and contact information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.