2. Safety Information

Always observe the following safety precautions to reduce the risk of injury or damage:

  • Ensure the power supply is disconnected before any installation, maintenance, or repair work.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Do not dispose of foreign objects (e.g., sanitary products, wet wipes, large amounts of paper) into the toilet, as this can cause blockages and damage the macerator pump.
  • Do not use abrasive cleaners or chemicals that could damage the ceramic or plastic components.
  • Ensure proper ventilation in the installation area.

3. Package Contents

Verify that all components are present and undamaged before beginning installation:

  • Macerating pump
  • Rear Toilet Unit
  • Toilet seat
  • Connection rings
  • Extension pipe

4. Specifications

Model NumberFD-JLF800
Power800W
Vertical Pumping HeightUp to 24 feet
Horizontal Pumping DistanceUp to 360 feet
Flush VolumeDual-flush: 1.28 GPF (Gallons Per Flush) or 0.8 GPF
Inlets4 (for shower, laundry, wash basin, toilet)
MaterialsABS, Ceramic, Stainless Steel, Polypropylene
Item Weight99.8 pounds
Package Dimensions32 x 31 x 17 inches
Flodream Macerating Toilet System Dimensions

Image 4.1: Product dimensions for the Flodream Macerating Toilet System.

Flodream Macerating Pump Dimensions

Image 4.2: Macerating pump dimensions.

5. Setup and Installation

Professional installation is recommended. Ensure all local plumbing and electrical codes are followed. This system allows for flexible bathroom placement, even below sewer lines.

5.1. Placement Considerations

  • The macerating pump can be installed up to 24 feet below the sewer line or 360 feet horizontally from a soil stack.
  • Ensure adequate space for the toilet unit and pump, as shown in the dimensions.
  • The system requires a dedicated electrical outlet.
Flodream Macerating Toilet Installation Example

Image 5.1: Example of a Flodream Macerating Toilet System installation.

5.2. Connecting the Macerating Pump

The macerating pump features multiple inlets for various wastewater sources:

  • Connect the toilet outlet to the main inlet of the macerating pump.
  • Utilize the additional 4 inlets for connecting a shower, laundry, or wash basin, as needed.
  • Ensure all connections are sealed properly to prevent leaks.
  • The dual water outlet design facilitates easy installation and high flow drainage.
Macerating Pump Inlets and Outlets

Image 5.2: Detailed view of the macerating pump showing inlets, discharge outlet, and stainless steel impeller blades.

5.3. Electrical Connection

Connect the macerating pump to a grounded electrical outlet. Refer to local electrical codes for specific requirements.

5.4. Toilet Seat Installation

The toilet features quick-release functionality for easy installation and removal of the seat. Attach the hardware securely.

Toilet Features: Soft Close Seat, Skirted Trapway, Quick-Release

Image 5.3: Key features including soft-close seat, fully skirted trapway, and quick-release functionality.

6. Operating Instructions

The Flodream Macerating Toilet System is designed for efficient and quiet operation.

6.1. Flushing

  • This toilet features a dual-flush mechanism. Use the smaller button for liquid waste (0.8 GPF) and the larger button for solid waste (1.28 GPF) to conserve water.
  • The macerator pump will activate automatically after flushing to grind waste and pump it to the main sewer line.

6.2. Macerator Pump Function

The 800W macerating pump incorporates a grinder system with ultra-sharp blades to liquefy waste before pumping. A built-in check valve prevents backflow.

Macerating Pump Internal Components

Image 6.1: Internal view highlighting the copper motor, ultra-sharp blade, and multiple connections.

Watch this video to understand how the macerating toilet system works:

Video 6.1: An animated explanation of how the Flodream macerating toilet system operates in a basement setting.

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your Flodream Macerating Toilet System.

7.1. Cleaning the Toilet Bowl

  • The ceramic glazed surface and concealed trapway are designed for easy cleaning.
  • Use mild, non-abrasive toilet bowl cleaners. Avoid harsh chemicals that could damage the finish or internal components.
  • The quick-release toilet seat can be easily removed for thorough cleaning.
Nano-Glaze Finished Toilet Bowl

Image 7.1: The nano-glaze finish promotes easy cleaning and hygiene.

Slow-Close Toilet Seat

Image 7.2: The slow-close seat can be easily removed for cleaning.

7.2. Macerator Pump Care

  • Periodically check the pump for any unusual noises or reduced performance.
  • Avoid flushing anything other than human waste and toilet paper.
  • If the pump requires servicing, disconnect power and contact qualified personnel.

8. Troubleshooting

This section addresses common issues you might encounter. For problems not listed here, please contact customer support.

ProblemPossible CauseSolution
Pump not runningNo power; tripped circuit breaker; motor obstruction.Check power connection and circuit breaker. Disconnect power and inspect for obstructions (professional assistance recommended).
Toilet not flushing properly / Slow drainagePartial blockage; insufficient water supply; pump issue.Ensure proper water supply. Avoid flushing non-biodegradable items. If problem persists, check pump for blockages (professional assistance recommended).
Unusual noise from pumpForeign object in pump; worn motor parts.Disconnect power immediately. Contact customer support or a qualified technician.
LeakageLoose connections; damaged seals.Check all pipe connections and tighten if necessary. Inspect seals for damage and replace if needed.

9. Warranty and Support

Flodream stands behind the quality of its products.

  • 24-Month Replacement: A replacement is available within 24 months from the date of purchase for manufacturing defects.
  • Lifetime After-Sales Service: We offer lifetime after-sales service and technical support for your product.

For warranty claims, technical assistance, or any questions, please contact Flodream customer support. Please have your model number (FD-JLF800) and purchase date available when contacting support.

Contact Information: support@flodream.com (Example email, actual contact details may vary)

Flodream Customer Support Information

Image 9.1: Flodream customer support details, including warranty and service information.

© 2023 Flodream. All rights reserved.