1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your EAPRO 3200 24 Solar MPPT Inverter. This device is designed to convert direct current (DC) from solar panels into alternating current (AC) for household or commercial use, while also managing battery charging through its integrated MPPT charge controller.
Please read this manual thoroughly before installation and operation to ensure optimal performance and longevity of the inverter.
2. Safety Instructions
WARNING: Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death.
- Installation must be performed by qualified personnel in accordance with all local electrical codes and regulations.
- Do not attempt to open or disassemble the inverter. There are no user-serviceable parts inside.
- Ensure the inverter is installed in a well-ventilated area, away from flammable materials, moisture, and direct sunlight.
- Always disconnect all power sources (AC, DC, and battery) before performing any maintenance or wiring.
- Use appropriate personal protective equipment (PPE) during installation and maintenance.
- Verify correct polarity for all DC connections (solar panels and batteries) to prevent damage to the inverter and other components.
- Ensure proper grounding of the inverter.
3. Product Overview
3.1 Key Features
- Integrated 100 A MPPT Solar Charge Controller for efficient solar energy harvesting.
- Supports up to 3000 Watt solar panels.
- Wide Panel VOC range of 72-110V.
- Capable of powering 1 HP & 1.5 HP submersible pumps up to 9 A load.
- Large LCD display for easy monitoring of system status.
- 3000VA/24V Inverter Capacity with 3000W Power Output.
3.2 Inverter Components
The EAPRO 3200 24 Solar MPPT Inverter features a user-friendly design with clearly labeled components.

Figure 3.2.1: Front View of the EAPRO 3200 24 Solar MPPT Inverter. This image displays the front panel of the inverter, featuring the LCD screen, control buttons, and the EAPRO branding. The yellow casing indicates the product's design.

Figure 3.2.2: Active LCD Display on EAPRO 3200 24 Solar MPPT Inverter. This image shows the inverter with its LCD display illuminated, indicating operational status and displaying system parameters such as voltage or charge status.

Figure 3.2.3: Rear View and Connection Ports of the EAPRO 3200 24 Solar MPPT Inverter. This image illustrates the back panel of the inverter, highlighting the various connection terminals for solar panels (PV Vmp), battery (24V DC), and AC input/output. Cooling fans and a reset button are also visible.
Front Panel:
- LCD Display: Shows real-time system information (voltage, current, battery status, load, etc.).
- Control Buttons: For navigation and setting adjustments (e.g., ON/OFF, UPS Mode, High Charge, Power Saving).
- LED Indicators: Provide quick status updates (e.g., power, fault, charging).
Rear Panel:
- Solar Input Terminals (PV Vmp): Connects to solar panel array.
- Battery Terminals (24V DC): Connects to the battery bank.
- AC Input/Output Terminals: For grid connection and AC load output.
- Cooling Fans: For thermal management.
- Reset Button: For system reset.
4. Setup and Installation
Before beginning installation, ensure all components are present and undamaged. Refer to the "Included Components" section for a list of items.
4.1 Site Selection
- Choose a cool, dry, and well-ventilated location.
- Avoid direct sunlight, high temperatures, and excessive humidity.
- Ensure sufficient clearance around the inverter for proper airflow (at least 20 cm on all sides).
- Mount the inverter vertically on a non-flammable surface.
4.2 Wiring Connections
IMPORTANT: Always disconnect all power sources before making any electrical connections.
- Battery Connection:
Connect the supplied Battery Connecting Leads to the inverter's 24V DC battery terminals and to your 24V battery bank. Ensure correct polarity: positive (+) to positive (+), and negative (-) to negative (-). Secure connections tightly.
- Solar Panel Connection:
Connect your solar panel array to the inverter's Solar Input Terminals (PV Vmp). Observe correct polarity. Ensure the total open-circuit voltage (Voc) of your solar array does not exceed the inverter's maximum input voltage (110V) and the total power does not exceed 3000W.
- AC Output Connection:
Connect your AC loads (appliances, lighting) to the inverter's AC Output Terminals. Ensure the total load does not exceed the inverter's rated output power (3000W).
- AC Input Connection (Optional, for Grid Charging/Bypass):
If using grid power for charging or bypass, connect the AC grid supply to the inverter's AC Input Terminals. This connection allows the inverter to charge batteries from the grid or pass grid power directly to loads when solar power is insufficient.
- Grounding:
Connect the inverter's grounding terminal to a reliable earth ground using appropriate gauge wire.
5. Operating Instructions
5.1 Powering On/Off
- To Power On: Ensure all connections are secure. First, connect the battery bank. Then, connect the solar panels. Finally, press the ON/OFF button on the front panel. The LCD display will illuminate, and the inverter will begin operation.
- To Power Off: First, disconnect the AC loads. Then, disconnect the solar panels. Finally, disconnect the battery bank. Press and hold the ON/OFF button until the inverter shuts down.
5.2 LCD Display and Settings
The large LCD display provides real-time information about the inverter's status. Use the control buttons to navigate through different display screens and adjust settings.
- Monitoring: The display typically shows battery voltage, solar charging current, AC output voltage, load percentage, and operational mode.
- Mode Selection:
- UPS Mode: Provides uninterrupted power supply, switching to battery power instantly during grid outages.
- High Charge: Prioritizes faster battery charging.
- Power Saving: Reduces power consumption when loads are low.
- Refer to the detailed settings menu in the full product manual for advanced configurations.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your EAPRO inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Connections: Annually inspect all electrical connections (battery, solar, AC) for tightness and corrosion. Tighten any loose connections.
- Battery Inspection: If using lead-acid batteries, check electrolyte levels and terminal condition regularly. Keep terminals clean and free of corrosion.
- Environment: Ensure the installation environment remains within specified temperature and humidity ranges.
7. Troubleshooting
This section addresses common issues you might encounter. For problems not listed here, contact EAPRO customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter does not power on. | No battery connection or low battery voltage. Loose battery terminals. | Check battery connections and ensure battery voltage is above the minimum operating level. Tighten terminals. |
| No AC output. | Overload condition. Inverter in fault mode. Output breaker tripped. | Reduce load. Check for fault codes on LCD. Reset output breaker. |
| Batteries not charging from solar. | No solar input. Incorrect solar panel connection. Low sunlight. | Check solar panel connections and polarity. Ensure panels are clean and not shaded. Verify solar input voltage on display. |
| Inverter making unusual noise. | Overload. Loose components. Fan obstruction. | Reduce load. Check for loose parts (only if safe and power is off). Ensure cooling fans are clear. |
8. Specifications
| Parameter | Value |
|---|---|
| Model Number | EGLM1P3200 MPPT 24V SOLAR |
| Inverter Capacity | 3000VA / 24V |
| Power Output | 3000 Watt |
| Integrated MPPT Charge Controller | 100 Amp |
| Max. Solar Panel Support | 3000 Watt |
| Panel VOC Range | 72-110V |
| Voltage | 24 Volts |
| Display Type | LCD |
| Item Dimensions (LxWxH) | 39 x 35 x 34 Centimeters |
| Item Weight | 23 kg |
| Included Components | Product Manual, Battery Connecting Lead, DC Fuses |
9. Warranty and Support
9.1 Warranty Information
The EAPRO 3200 24 Solar MPPT Inverter comes with a 2 Year Warranty from the date of purchase. This warranty covers manufacturing defects and faulty workmanship under normal use conditions. It does not cover damage caused by improper installation, misuse, accidents, unauthorized modifications, or natural disasters.
Please retain your purchase receipt as proof of purchase for warranty claims.
9.2 Customer Support
For technical assistance, warranty claims, or any other inquiries, please contact EAPRO customer support:
- Manufacturer: EAPRO GLOBAL LIMITED
- Address: Plot No. 106-107, Salempur Rajputana Industrial Area, Roorkee - 247667, Distt. Haridwar (U.K.), INDIA
- Phone: +918650115000