Introduction
This manual provides essential information for the safe and efficient operation of your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater. Please read all instructions carefully before installation, operation, or maintenance. Retain this manual for future reference.

Image: Front view of the ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, showcasing its compact design and infrared heating plaques.
Safety Information
Your ProCom heater is designed with safety in mind. It is a ventless unit, meaning it does not require an outside duct or chimney. However, proper ventilation is still crucial for safe operation. This heater is equipped with an Oxygen Depletion Sensor (ODS) that automatically shuts down the unit if oxygen levels become too low. It is ANSI Certified to ensure safety standards are met.
- Always ensure adequate air circulation in the room where the heater is operating.
- Do not obstruct the air intake or exhaust vents of the heater.
- Never use this heater in a recreational vehicle or boat.
- Keep flammable materials at a safe distance from the heater.
- Regularly inspect the gas connections for leaks.
Product Features
- Infrared Heat Technology: Produces 18,000 Maximum BTU, heating up to 950 sq. ft.
- Ventless Design: No outside duct or chimney required.
- Natural Gas Operation: Designed exclusively for natural gas fuel.
- Thermostat Control: Allows setting to desired comfort level with High/Medium/Low settings.
- Piezo Ignition: Push-button ignition for easy startup, no electricity or batteries required.
- Oxygen Depletion Sensor (ODS): Automatically shuts off the heater if oxygen levels drop.
- Versatile Installation: Can be mounted on a wall or placed on the floor using included base feet.

Image: Diagram highlighting key features of the ProCom heater, including BTU output, ventless operation, natural gas compatibility, no electricity requirement, safety features, Piezo ignition, and thermostat mode.
Setup
The ProCom MN180TPA-B heater offers flexible installation options: wall-mounted or floor-standing.
Unpacking and Inspection
- Carefully remove all packaging materials.
- Inspect the heater for any shipping damage. Do not install a damaged unit.
- Ensure all components listed in the packing list are present.
Choosing a Location
Select a location that allows for proper clearances from combustible materials. Ensure the area has adequate ventilation as per local codes and the heater's specifications.
Installation Options
Floor Standing: Attach the included base feet to the bottom of the heater using the provided hardware. Ensure the heater is stable and level.
Wall Mounting: Use the included wall mounting bracket and hardware. Follow the detailed instructions in the manufacturer's full installation guide for secure wall attachment and proper clearances.

Image: Components included with the ProCom heater, showing the main unit, base feet, wall bracket, and highlighting the Oxygen Depletion Sensor and natural gas operation.

Image: The ProCom MN180TPA-B heater mounted on a wall in a living space, demonstrating its compact profile and integration into a room.
Gas Connection
This heater operates on natural gas only. Connection to the natural gas supply must be performed by a qualified professional in accordance with all local codes and regulations. Ensure all connections are leak-tested before operation.
Operating Instructions
Follow these steps to safely operate your ProCom MN180TPA-B heater.
Ignition Procedure
- Ensure the gas supply valve is open.
- Turn the control knob to the 'PILOT' position.
- Press and hold the control knob in while simultaneously pressing the Piezo ignition button repeatedly until the pilot flame ignites.
- Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up. Release the knob; the pilot should remain lit.
- If the pilot does not remain lit, repeat steps 2-4.
- Once the pilot is stable, turn the control knob to the desired heat setting (1-5). The main burner will ignite.
Thermostat Control
The heater features a thermostat control with 5 variable heat settings. Rotate the control knob to select your preferred heat output. The heater will cycle on and off to maintain the set temperature.

Image: Close-up view of the control panel on the ProCom heater, showing the Piezo ignitor button and the rotary knob for 5 variable heat settings and pilot control.
Shutting Down the Heater
- Turn the control knob to the 'OFF' position.
- For prolonged shutdown, close the main gas supply valve to the heater.
Maintenance
Regular maintenance ensures the longevity and safe operation of your heater.
- Cleaning: Ensure the heater is completely cool before cleaning. Use a soft, damp cloth to wipe down the exterior. Do not use abrasive cleaners.
- Pilot and Burner Inspection: Periodically inspect the pilot and burner ports for dust or debris. Clean gently with a soft brush if necessary.
- Gas Connections: Annually check all gas connections for tightness and signs of wear.
- Professional Service: It is recommended to have the heater inspected by a qualified service technician at least once a year.
Troubleshooting
If you encounter issues with your heater, refer to the following common problems and solutions. For persistent issues, contact a qualified service technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pilot will not light | No gas supply; Air in gas line; Pilot orifice clogged; Faulty thermocouple | Check gas supply; Purge air from line; Clean pilot orifice; Contact technician |
| Pilot lights but will not stay lit | Thermocouple not heating sufficiently; Loose thermocouple connection; Faulty ODS pilot assembly | Hold knob longer; Tighten connection; Contact technician |
| Main burner will not ignite | Pilot not lit; Main burner orifice clogged; Low gas pressure | Ensure pilot is lit; Clean burner orifice; Contact gas provider/technician |
| Heater cycles off frequently | Insufficient ventilation; ODS activation; Thermostat setting too high for room size | Increase ventilation; Check for obstructions; Adjust thermostat setting |
Specifications
| Attribute | Detail |
|---|---|
| Brand | ProCom |
| Model Number | MN180TPA-B |
| Fuel Type | Natural Gas |
| Maximum BTU Output | 18,000 BTU |
| Heating Coverage | Up to 950 sq. ft. |
| Ignition Type | Push Button Piezo |
| Control Type | Thermostat (High/Medium/Low) |
| Safety Features | Oxygen Depletion Sensor (ODS) |
| Mounting Options | Wall Mount, Floor Standing (Base Feet Included) |
| Product Dimensions | 8"D x 22"W x 26"H |
| Item Weight | 26.2 pounds |
| Color | White |
| Certifications | CSA Certified, ANSI Certified |

Image: Diagram illustrating the dimensions of the ProCom MN180TPA-B heater: 24 inches H, 19 inches L, and 8 inches D.
Warranty Information
For detailed warranty information regarding your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, please refer to the warranty card included with your product packaging or visit the official ProCom website. Warranty terms and conditions may vary.
Customer Support
If you require assistance, have questions about your heater, or need to report an issue, please contact ProCom customer support. Refer to your product packaging or the official ProCom website for the most current contact information, including phone numbers, email addresses, and online support resources.