1. Product Overview
The Comap FlexoDesign M30 L234023001 is a versatile thermostatic valve set designed for efficient control of heating systems, particularly for towel dryers and bathroom radiators without integrated valves. This multibloc solution offers flexible installation options and is compatible with various pipe types, providing both angle and straight configurations.

2. Key Features
- Convertible Design: Easily switch between straight and angled configurations without the need for additional tools.
- Flexible Thermostatic Head Mounting: The thermostatic head can be mounted on either the right or left side of the valve.
- Reversible Inlet/Outlet: The valve set features a reversible inlet and outlet, allowing for adaptable pipe connections.
- Integrated Kit: Includes the thermostatic head, valve, and cover, providing a complete solution for aesthetic integration with bathroom radiators.
- Pre-set Kv Value: Equipped with a pre-set Kv value for precise and efficient flow regulation within the radiator system.


3. Package Contents
The Comap FlexoDesign M30 L234023001 Thermostatic Valve Set package includes:
- 1 x Comap FlexoDesign M30 L234023001 Thermostatic Valve Kit (comprising valve body, thermostatic head, and cover)
4. Installation Guide
4.1. General Installation Notes
- Ensure all components are present and undamaged before beginning installation.
- Installation should be performed by a qualified professional in accordance with local plumbing and heating regulations.
- Before starting, turn off the main heating system and drain the radiator or towel dryer to be fitted.
- Always use appropriate tools and safety equipment.
4.2. Connecting the Valve Set
The FlexoDesign valve set is designed for connection to copper, mild steel, stainless steel, PEX, or multi-layer tubes. It utilizes 3/4" Eurocone connections for which corresponding clamping fittings (not included) must be used to ensure secure and leak-free connections.
The valve set's convertible design allows it to be configured as either a straight or angled valve. Its reversible inlet/outlet feature provides flexibility for pipe routing, whether pipes come from the floor or the wall. The valve can be installed on either the right or left side of the radiator or towel dryer.
- Prepare the radiator connections by ensuring they are clean and free of debris.
- Attach the appropriate 3/4" Eurocone clamping fittings to your pipework.
- Connect the valve set to the radiator and the pipework, ensuring all connections are tightened securely to prevent leaks.
- Mount the thermostatic head onto the valve body.
- Once installed, slowly refill the heating system and check for any leaks.

5. Operating Instructions
5.1. Thermostatic Control
The thermostatic head allows you to set the desired room temperature. Rotate the head to align the desired setting with the indicator mark on the valve body. The markings (e.g., 1, 2, 3, 4) typically correspond to increasing temperature levels.
- Setting '0' or '*': Frost protection setting, maintaining a minimum temperature to prevent freezing.
- Settings 1-5 (or similar): Correspond to a range of temperatures, with higher numbers indicating warmer settings. Refer to your heating system's guidelines for specific temperature correlations.
The pre-set Kv value within the valve ensures optimal flow regulation, contributing to efficient and consistent heating performance.
6. Maintenance
6.1. General Care
- Cleaning: Clean the exterior of the valve set with a soft, damp cloth. Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish.
- Inspection: Periodically check all connections for any signs of leaks. Address any leaks immediately by tightening connections or seeking professional assistance.
- Thermostatic Head: Ensure the thermostatic head can rotate freely. If it feels stiff, gently rotate it through its full range of motion a few times.
No specific user maintenance is required for the internal components of the valve. For any internal issues or complex repairs, it is recommended to consult a qualified heating technician.
7. Troubleshooting
7.1. Common Issues and Solutions
- No Heat or Insufficient Heat from Radiator:
- Ensure the thermostatic head is set to a sufficiently high temperature.
- Verify that the main heating system is operational and supplying hot water.
- Check if the radiator needs bleeding to release trapped air.
- Confirm proper flow through the valve.
- Leaks Around Connections:
- Carefully tighten the connections using appropriate tools. Do not overtighten.
- If leaks persist, the sealing washers or fittings may need replacement. Professional assistance is recommended.
- Stuck Thermostatic Head:
- Gently try to rotate the head through its full range of motion.
- If it remains stuck, the internal pin may be jammed. This often requires professional intervention or replacement of the thermostatic head.
For any persistent problems or issues not covered here, contact a qualified heating technician or Comap customer support.
8. Technical Specifications
| Attribute | Value |
|---|---|
| Brand | Comap |
| Model Number | L234023001 |
| Product Type | Thermostatic Valve Set |
| Connection Size | 1/2" M (Multibloc, 3/4" Eurocone for fittings) |
| Compatibility | Copper, mild steel, stainless steel, PEX, multi-layer tubes |
| Configuration | Convertible (Angle/Straight), Reversible Inlet/Outlet |
| Color | Black |
| Batteries Required | No |
| Included Components | 1 Thermostatic Valve Kit |
9. Warranty and Support
For detailed warranty information, terms, and conditions, please refer to the official Comap website or the documentation provided with your purchase. Keep your purchase receipt as proof of purchase for any warranty claims.
For technical support, spare parts, or further assistance, please contact your local Comap distributor or authorized service center. Contact information can typically be found on the Comap official website.