Rosvola Rosvolaeoicgvd09p-12
Rosvola Water Leakage Detection Kit User Manual
Model: Rosvolaeoicgvd09p-12
1. Product Overview
The Rosvola Water Leakage Detection Kit is a high-strength sound intensifier designed for monitoring water pipe leakages. It is suitable for various applications including site construction, car maintenance, and general water pipe inspection. The device features a dual probe design for versatile detection and includes high-definition earphones for clear sound detail. It is powered by a built-in rechargeable battery.

Image 1.1: Overview of the Rosvola Water Leakage Detection Kit components, including the main unit, headphones, two types of probes, and charging accessories.

Image 1.2: The device is suitable for various locations such as bathrooms, kitchens, outdoor plumbing, underground pipes, wall pipes, and automotive pipes.
2. Setup
Before operating the device, ensure all components are present and the main unit is charged.
2.1. Charging the Device
The device is supplied with a built-in 3.7V battery and a power adapter. Connect the charging cable to the host's charging jack and the power adapter. The indicator light will be red during charging and turn green when fully charged. A full charge typically takes 12 hours.

Image 2.1: The HY929 unit indicating the charging jack and indicator light for charging status.
2.2. Connecting Probes and Earphones
The kit includes two types of detection probes: a flat probe and a long probe (needle probe). Select the appropriate probe based on the detection environment.
- Flat Probe: Use the flat probe by connecting it to the audio input jack. Ensure the button on the probe is facing to the right when inserted.
- Long Probe (Needle Probe): Use the long probe by connecting it to the audio input jack. Ensure the button on the probe is facing to the left when inserted.
- Earphones: Plug the high-definition earphones into the Audio Output Jack on the main unit.

Image 2.2: Detailed view of the HY929 unit, highlighting the switch for probe selection (long probe left, flat probe right) and the switch/volume adjustment knob.
Video 2.1: Demonstration of connecting the flat probe and long probe, adjusting the switch, and charging the main unit.
3. Operating Instructions
Follow these steps to effectively use the water leakage detection kit:
- Connect Components: Ensure the selected probe and earphones are securely connected to the main unit as described in Section 2.2.
- Power On and Adjust Volume: Turn on the device using the switch/volume adjustment knob. Slowly adjust the volume to a comfortable listening level.
- Select Probe Mode: Use the switch to select the correct mode for the connected probe (left for long probe, right for flat probe).
- Begin Detection: Place the probe firmly against the surface where you suspect a leak. Listen carefully through the earphones for sounds of water leakage, such as dripping, flowing, or bubbling.
- Pinpoint Leak Location: Move the probe systematically across the suspected area. The sound of the leak will become louder as you get closer to its source.

Image 3.1: An individual utilizing the water leak detector to identify a leak under a sink, demonstrating practical application.

Image 3.2: Visual representation of how the device helps pinpoint pipe ruptures by distinguishing between leaking and dripping sounds.
4. Maintenance
Proper maintenance ensures the longevity and optimal performance of your device.
- Cleaning: Wipe the main unit and probes with a soft, dry cloth after each use. Do not use abrasive cleaners or immerse the unit in water.
- Storage: Store the device and its components in a cool, dry place away from direct sunlight and extreme temperatures.
- Probe Care: The probes are delicate. Handle them with care and avoid excessive force or bending, especially the needle probe.
- Battery Care: Charge the device regularly, even if not in frequent use, to maintain battery health. Avoid completely draining the battery before recharging.
5. Troubleshooting
If you encounter issues with your device, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No sound from earphones. |
|
|
| Weak or unclear sound. |
|
|
| Device not charging. |
|
|
6. Specifications
- Model: Rosvolaeoicgvd09p-12
- Current Consumption: 15mA
- Suitable Battery: 3.7V Lithium Battery (Built-in)
- Probe Sensitivity: 70dB
- Maximum Audio Amplification: 20000X
- Penetration: Suitable for pipes (cement pipes, steel pipes, etc.)
- Listening Method: 32Ω earphones, can be connected to an external 16Ω speaker
- Package Dimensions: 8.03 x 5.47 x 1.57 inches
- Item Weight: 12.63 ounces
- Manufacturer: Rosvola
- Country of Origin: China
7. Warranty and Support
For warranty information and technical support, please refer to the product packaging or contact Rosvola customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.
Important Note: This product is intended for use in construction sites, automotive repair, etc., and should not be used for other purposes.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.