RaeSung TM-188D

TENMARS TM-188D Handheld Heat Stress WBGT Meter with Datalogger User Manual

1. Introduction

The TENMARS TM-188D is a professional handheld meter designed for accurate measurement of various environmental parameters related to heat stress. It provides readings for Wet Bulb Globe Temperature (WBGT), Black Globe Temperature (TG), relative humidity (%RH), air temperature (TA), wet bulb (WET), and dew point (DEW). This device is equipped with a datalogging function, allowing for the recording of up to 12,000 records, making it suitable for long-term monitoring in various industrial and scientific applications. This manual provides essential information for the proper setup, operation, and maintenance of your TM-188D meter.

TENMARS TM-188D Heat Stress WBGT Meter front view

Figure 1: Front view of the TENMARS TM-188D Heat Stress WBGT Meter, showing the display, sensors, and control buttons.

2. Key Features

  • Quick-response capacitance sensor for precise measurements.
  • Measures Wet Bulb Globe Temperature (WBGT), Black Globe Temperature (TG), Humidity (%RH), Air Temperature (TA), Wet Bulb (WET), and Dew Point (DEW).
  • Max/Min and Data Hold functions for convenient data analysis.
  • Low battery indication for timely power management.
  • LCD display with LED backlight for clear visibility in various lighting conditions.
  • Single data record capability and viewing of recorded data.
  • Switchable temperature units between ℃ (Celsius) and ℉ (Fahrenheit).
  • Features a brass black ball with a 50mm diameter.
  • Adjustable WBGT alarm setting.
  • Automatic power off with a disable function to conserve battery life.
  • USB PC serial interface for data transfer (TM-188D model).
  • Datalogging capacity of 12,000 records (TM-188D model).
  • Adjustable sampling interval from 1 second to 24 hours (TM-188D model).

3. Setup

3.1 Unpacking and Inspection

Carefully unpack the TM-188D meter and all accessories. Inspect the device for any signs of damage that may have occurred during transit. If any damage is found, contact your supplier immediately.

3.2 Battery Installation

The TM-188D operates on standard batteries. To install or replace batteries:

  1. Locate the battery compartment cover on the back of the device.
  2. Open the cover by sliding or unscrewing it as indicated.
  3. Insert the batteries, ensuring correct polarity (+ and -).
  4. Close the battery compartment cover securely.
Back view of TENMARS TM-188D showing battery compartment

Figure 2: Rear view of the TM-188D, illustrating the battery compartment location.

3.3 Connecting to Power Adapter (Optional)

For extended use or datalogging, the TM-188D can be powered via an AC adapter.

  1. Connect the provided AC100~240V DC9V/0.5A adapter to the power input jack on the meter.
  2. Plug the adapter into a suitable power outlet.
TENMARS TM-188D with USB cable and power adapter

Figure 3: The TM-188D meter connected to its USB cable and power adapter.

3.4 Software Installation (for Datalogging)

For datalogging and PC interface functionality, install the provided software from the installation disk.

  1. Insert the installation disk into your computer's CD/DVD drive.
  2. Follow the on-screen instructions to install the necessary drivers and software.
  3. Connect the meter to your PC using the supplied USB cable.

4. Operating Instructions

4.1 Power On/Off

Press the POWER button to turn the meter on or off. The LCD backlight will illuminate upon power-on.

4.2 Measurement Modes

The TM-188D can measure various parameters. Use the MODE button to cycle through the available measurement displays: WBGT, TG, %RH, TA, WET, and DEW.

4.3 Temperature Unit Selection

Press the UNIT button to switch between Celsius (℃) and Fahrenheit (℉) temperature units.

4.4 Max/Min and Data Hold

  • Press MAX/MIN once to display the maximum recorded value. Press again for the minimum value. Press a third time to exit Max/Min mode.
  • Press HOLD to freeze the current reading on the display. Press again to release.

4.5 WBGT Alarm Setting

The WBGT alarm function allows you to set a threshold for heat stress. Refer to the detailed instructions in the full user manual for specific steps on setting and enabling the WBGT alarm.

4.6 Datalogging

The TM-188D can record up to 12,000 data points. To initiate datalogging:

  1. Ensure the meter is connected to the PC with the software running, or configure the sampling interval directly on the device if supported.
  2. Press the REC button to start recording data. The REC indicator will appear on the display.
  3. Press REC again to stop recording.
  4. To view recorded data, use the PC software or the meter's built-in data viewing function (refer to the full manual for navigation).

5. Maintenance

5.1 Cleaning

Wipe the meter's casing with a soft, damp cloth. Do not use abrasive cleaners or solvents. Keep the sensors clean and free from dust and debris to ensure accurate readings.

5.2 Storage

When not in use for extended periods, remove the batteries to prevent leakage. Store the meter in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.

TENMARS TM-188D and accessories neatly packed in a carrying case

Figure 4: The TM-188D meter and its accessories stored securely within the provided carrying case.

6. Troubleshooting

ProblemPossible CauseSolution
Meter does not power onLow or dead batteries; Incorrect battery installationReplace batteries; Check battery polarity
Inaccurate readingsDirty sensors; Environmental interference; Calibration requiredClean sensors carefully; Move to a stable environment; Contact service for calibration
Datalogging not workingMemory full; Incorrect settings; PC connection issueDownload and clear data; Verify sampling interval and REC mode; Check USB cable and software installation
LCD display is dimLow battery; Backlight offReplace batteries; Press backlight button (if available)

7. Specifications

ParameterValue
Dimensions300 x 70 x 50 mm (Length x Width x Height)
WeightApproximately 220 grams
Datalogging Capacity12,000 records (TM-188D)
Sampling IntervalMax 24 hours; Min 1 Second (TM-188D)
InterfaceUSB PC serial interface (TM-188D)
Black Globe Diameter50mm (Brass)
ManufacturerRaeSung
Model NumberTM-188D

8. Accessories

The following accessories are included with your TENMARS TM-188D meter:

  • User's Manual
  • Carrying Case
  • USB Cable (for TM-188D)
  • AC100~240V DC9V/0.5A Power Adapter (for TM-188D)
  • Installation Disk (for TM-188D)
TENMARS TM-188D meter and all included accessories laid out

Figure 5: The TM-188D meter displayed with its complete set of accessories, including the manual, cables, and power adapter.

9. Warranty and Support

For warranty information and technical support, please refer to the specific warranty card included with your product or contact your authorized dealer. Keep your purchase receipt as proof of purchase for any warranty claims.