1. Introduction

The KETOTEK KT6000 is a versatile digital temperature and humidity controller designed for precise environmental management. It features dual relay outputs, allowing independent control of heating/cooling and humidification/dehumidification devices. With its day/night programming capabilities and alarm functions, it is ideal for applications such as terrariums, incubators, and greenhouses, ensuring optimal conditions for your specific needs.

2. Key Features

  • Dual Relay Output: One output for temperature control, one for humidity control.
  • Day/Night Programming: Set different temperature and humidity parameters for day and night cycles.
  • Wide Control Range: Temperature control from 0~50℃, humidity control from 1-99% RH.
  • Buzzer Alarm: Alerts for over-temperature or over-humidity conditions.
  • Compressor Delay Start Protection: Protects connected cooling devices.
  • Large LCD Display: Backlit display for clear readings.
  • Data Storage: All parameters are saved even after power off.
  • Long Probe: 1.5m temperature and humidity probe for flexible placement.

3. Package Contents

KETOTEK KT6000 package contents including the controller, probe, and manual.

Figure 3.1: KETOTEK KT6000 controller, temperature/humidity probe, power cable, user manual, and mounting velcro strips.

  • 1 x KETOTEK KT6000 Thermostat Hygrostat Unit
  • 1 x Combined Temperature and Humidity Probe (1.5m)
  • 1 x Power Cable
  • 1 x User Manual
  • Mounting Velcro Strips

4. Product Overview

Front view of the KETOTEK KT6000 controller with its display and dual power outlets.

Figure 4.1: Main components of the KETOTEK KT6000 controller.

Close-up of the KETOTEK KT6000 display showing temperature, humidity, and various function icons.

Figure 4.2: Detailed view of the LCD display and control buttons.

  • LCD Display: Shows current temperature, humidity, and various status icons.
  • Control Buttons: Up, Down, and SET buttons for navigation and parameter adjustment.
  • Dual Power Sockets: Two independent outlets for connecting heating/cooling and humidifying/dehumidifying devices.
  • Temperature/Humidity Probe: External probe for accurate environmental sensing.

5. Setup

Follow these steps to set up your KETOTEK KT6000 controller:

  1. Unpack the Device: Carefully remove all components from the packaging.
  2. Connect the Probe: Plug the combined temperature and humidity probe into the designated port on the controller unit. Ensure it is securely connected.
    Close-up of the temperature and humidity probe.

    Figure 5.1: The temperature and humidity probe.

  3. Position the Probe: Place the probe in the environment you wish to monitor and control (e.g., terrarium, incubator). Ensure it is not directly exposed to heat sources or moisture that could skew readings.
  4. Connect Power: Plug the main power cable of the KT6000 unit into a standard 220V power outlet. The LCD display will light up.
    Diagram showing how to connect the KETOTEK KT6000 to power and external devices.

    Figure 5.2: Connection diagram for the KT6000.

  5. Connect Devices: Plug your heating/cooling device into the temperature control socket and your humidifying/dehumidifying device into the humidity control socket.
    Close-up of the dual power sockets on the KETOTEK KT6000.

    Figure 5.3: Dual power sockets for connecting external devices.

  6. Mounting (Optional): Use the provided velcro strips to mount the display unit and the main control unit in a convenient location.
    Image showing the adhesive velcro strips for mounting.

    Figure 5.4: Mounting velcro strips.

6. Operating Instructions

6.1. Basic Operation

Upon powering on, the display will show the current temperature (RT) and relative humidity (RH) measured by the probe.

6.2. Setting Temperature Parameters

The KT6000 allows for independent day and night temperature settings.

Table showing temperature regulation parameters and their settings.

Figure 6.1: Temperature Regulation Parameters.

CodeSignificationSetting Range
MTemperature control modeHEAT/COOL
DAY SETDay temperature setting0~50℃
NIGHT SETNight temperature setting0~50℃
DIFFERENCEDifferential value (Hysteresis)0.1~20℃
ALARMOver-temperature alarm value1~20℃
☀️Day start time00:00~22:59
🌙Night start time01:00~23:59

To adjust these parameters:

  1. Press and hold the SET button for 3 seconds to enter the parameter setting mode.
  2. Use the Up and Down buttons to navigate through the codes (M, DAY SET, NIGHT SET, etc.).
  3. Press SET again to select a parameter. Use Up and Down to change its value.
  4. Press SET to confirm the value and move to the next parameter, or wait 10 seconds for the device to automatically save and exit.

6.3. Setting Humidity Parameters

Similar to temperature, you can set independent day and night humidity levels.

Table showing humidity regulation parameters and their settings.

Figure 6.2: Humidity Regulation Parameters.

CodeSignificationSetting Range
MHumidity control modeHUMI/DEHUMI
DAY SETDay humidity setting1~99% RH
NIGHT SETNight humidity setting1~99% RH
DIFFERENCEDifferential value (Hysteresis)1~30% RH
ALARMOver-humidity alarm value1~30% RH
☀️Day start time00:00~22:59
🌙Night start time01:00~23:59

The adjustment procedure is the same as for temperature parameters.

6.4. Day/Night Cycle Programming

The device automatically switches between day and night settings based on the configured start times.

Diagram illustrating day and night temperature and humidity cycles over 24 hours.

Figure 6.3: Day/Night cycle programming concept.

Ensure the Day start time and Night start time are set correctly to define your 24-hour cycle. For example, if Day starts at 07:00 and Night starts at 18:00, the device will operate on day settings from 07:00 to 17:59 and on night settings from 18:00 to 06:59 the next day.

6.5. Alarm Function

The KT6000 features audible and visual alarms for out-of-range conditions.

  • When temperature or humidity exceeds the set ALARM threshold, the alarm indicator will flash, and a buzzer will sound.
  • The buzzer sound can be disabled in the settings if desired.

7. Maintenance

  • Cleaning: Wipe the unit and probe with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.
  • Probe Care: Keep the probe clean and free from debris. Avoid bending or damaging the probe cable.
  • Storage: When not in use, store the device in a cool, dry place away from direct sunlight and extreme temperatures.

8. Troubleshooting

ProblemPossible CauseSolution
Display is blankNo power; loose connection.Check power outlet; ensure power cable is securely plugged in.
Inaccurate readingsProbe dirty or damaged; probe incorrectly placed.Clean the probe; ensure probe is in a representative location; replace probe if damaged.
Connected device not turning on/offIncorrect parameter settings; device malfunction.Verify DAY SET/NIGHT SET and DIFFERENCE values; check if the connected device is working independently.
Alarm constantly soundingALARM threshold too narrow; actual environment outside desired range.Adjust ALARM parameter; check environmental conditions and connected devices.

9. Specifications

ParameterValue
BrandKETOTEK
Model NumberKT6000
ColorBlack
Voltage230 Volts
Power SourceElectric Cable
Temperature Control Range0~50℃
Humidity Control Range1-99% RH
Probe Length1.5 meters
Item Weight650 grams
Package Dimensions23.4 x 13.7 x 6.3 cm
Connectivity TechnologyWired
Specific UsesGreenhouse, Terrarium
Country of OriginChina

10. Warranty and Support

KETOTEK products are designed for reliability and performance. For any questions, technical support, or warranty inquiries, please contact KETOTEK customer service through your purchase platform or the official KETOTEK website. Please retain your proof of purchase for warranty claims.