1. Introduction and Overview
The Halex 60 Amp 240-Volt Non-Fused Metallic AC Disconnect, Model HNF60R, is designed to provide a safe and reliable method for disconnecting power to outdoor electrical equipment such as air conditioning units, mini-splits, heat pumps, spas, and well pumps. This device ensures safe working conditions by allowing for complete isolation of the equipment from the main power supply. It features a pull-out type switch and is UL Listed, ANSI Certified, and NEMA 3R rated for outdoor use.
2. Safety Information
WARNING: Installation and servicing of this electrical disconnect must be performed by a qualified electrician in accordance with all national and local electrical codes. Failure to do so may result in serious injury, death, or property damage.
- Always disconnect power at the main service panel before installing or servicing this unit.
- Verify that the power is off using a voltage tester before proceeding with any work.
- Ensure proper grounding and bonding as required by electrical codes.
- This disconnect is rated for 60 AMP and up to 240V. Do not exceed these ratings.
- The unit is UL Listed and ANSI Certified, meeting safety standards.
- NEMA 3R rated enclosure provides protection against rain, sleet, and external ice formation.
3. Product Features
- Non-Fused Pull-Out Switch: Provides a clear visual indication of power disconnection, ensuring safe isolation during maintenance or repair.
- Durable Metallic Enclosure: Constructed from metallic powder-coated galvanized steel for enhanced durability and weather resistance.
- NEMA 3R Rated: Suitable for outdoor installations, protecting internal components from environmental elements.
- Easy Installation: Features an easy-to-remove cover, fast 2-point mounting, and pre-punched knockouts for simplified wiring.
- Wide Wire Compatibility: Supports copper conductors from 14 AWG to 3 AWG and aluminum conductors from 12 AWG to 3 AWG.
- Padlockable Door: Allows for securing the disconnect in the OFF position to prevent unauthorized re-energization.

Figure 1: Internal view of the Halex HNF60R disconnect with the pull-out switch removed, highlighting the wiring terminals.

Figure 2: The Halex HNF60R disconnect box installed on an exterior wall, showcasing its weather-resistant enclosure.
4. Setup and Installation
Before beginning installation, ensure all power to the circuit is OFF at the main breaker panel. This device must be installed by a qualified professional.
- Mounting: Select a suitable outdoor location for the disconnect box, ensuring it is within sight of the equipment it serves. Use the two-point mounting holes to securely fasten the enclosure to a stable surface.
- Knockouts: Utilize the pre-punched knockouts (sized for 1/2", 3/4", and 1" conduit and cable) to bring the supply and load wires into the enclosure. Remove knockouts carefully to avoid damage.
- Wiring: Connect the supply (LINE) wires to the designated LINE terminals and the load (LOAD) wires to the designated LOAD terminals. Connect the equipment ground wire to the ground lug. Refer to the internal label for clear line/load orientation and accepted wire ranges.
- Torque Specifications: Ensure all terminal screws are tightened to the specified torque values to prevent loose connections and potential hazards. Consult the table below for detailed lug specifications.
- Close and Secure: Once wiring is complete and verified, replace the cover and ensure it is securely latched. The door is padlockable for added security.

Figure 3: Wiring in progress inside the Halex HNF60R disconnect box.
Cable Ranges & Torque Values (60/75°C AL-CU Wire)
| Wire Size (AWG) | LINE/LOAD | EQUIPMENT GROUND | Connector Torque (LB-IN) | |||
|---|---|---|---|---|---|---|
| CU | AL | CU | AL | LINE/LOAD | EQUIPMENT GROUND | |
| 14 | 14 | - | 14 | - | 35 | 20 |
| 10 – 12 | 10 – 12 | 10 – 12 | 10 – 12 | 10 – 12 | 35 | 20 |
| 8 | 8 | 8 | 8 | 8 | 40 | 25 |
| 6 – 4 | 6 – 4 | 6 – 4 | 6 – 4 | 6 – 4 | 45 | 35 |
| 3 | 3 | 3 | - | - | 50 | - |
Always consult the National Electrical Code (NEC) and all applicable local codes before installation.
5. Operating Instructions
The Halex HNF60R disconnect operates using a simple pull-out switch mechanism.
- To Disconnect Power (OFF): Firmly grasp the pull-out switch handle and pull it straight out from the enclosure. This action physically separates the electrical contacts, interrupting the power supply to the connected equipment. The switch is clearly marked with ON/OFF indicators.
- To Connect Power (ON): Align the pull-out switch with the slots in the enclosure and push it firmly into place until it is fully seated. This action engages the electrical contacts, restoring power to the connected equipment.
- Safety Lockout: For added safety during maintenance, the pull-out switch can be removed and stored separately, or the enclosure door can be padlocked in the OFF position to prevent accidental re-energization.

Figure 4: Demonstrating the removal of the pull-out switch for power disconnection.
6. Maintenance
The Halex HNF60R non-fused disconnect is designed for minimal maintenance due to its robust construction and NEMA 3R rating.
- Periodic Inspection: Annually inspect the enclosure for any signs of physical damage, corrosion, or loose connections. Ensure the door latch operates correctly and the enclosure remains sealed.
- Cleaning: Keep the exterior of the enclosure clean from dirt, dust, and debris. Use a damp cloth if necessary. Do not use abrasive cleaners or solvents.
- Terminal Check: If the enclosure is opened for any reason, visually inspect the wire terminals for tightness and signs of overheating. Re-torque connections if necessary, ensuring power is disconnected first.
7. Troubleshooting
If you experience issues with your Halex HNF60R disconnect, consider the following common troubleshooting steps:
- No Power to Equipment:
- Ensure the pull-out switch is fully inserted into the ON position.
- Check the main circuit breaker in your electrical panel to ensure it has not tripped.
- Verify all wire connections within the disconnect are secure (only by a qualified electrician with power off).
- Difficulty Inserting/Removing Pull-Out Switch:
- Ensure the switch is aligned correctly with the guide slots.
- Check for any obstructions or debris within the switch mechanism.
- Visible Damage to Enclosure or Components:
- If any part of the disconnect is damaged, discontinue use immediately and contact a qualified electrician for replacement.
For issues not resolved by these steps, professional electrical assistance is recommended.
8. Specifications
| Specification | Value |
|---|---|
| Model | HNF60R |
| Amperage Rating | 60 AMP |
| Voltage Rating | 120/240 Volts AC |
| Enclosure Type | Non-Fused, Pull-Out Switch |
| NEMA Rating | 3R (Outdoor Use) |
| Certifications | UL Listed, ANSI Certified |
| Material | Metallic Powder-coated Galvanized Steel |
| Wire Compatibility | Copper: 14-3 AWG, Aluminum: 12-3 AWG |
| Included Components | Puller Type Disconnect |
| Item Weight | 2.5 Pounds |
| Dimensions (L x W x H) | 15"L x 11"W x 8.2"H (Approximate) |
9. Warranty Information
Specific warranty details for the Halex HNF60R 60 AMP AC Non-Fused Disconnect are not provided in this manual. For information regarding product warranty, please refer to the documentation included with your purchase or contact Halex customer service directly. Proof of purchase may be required for warranty claims.
10. Support and Contact Information
For technical assistance, product inquiries, or support, please contact Halex customer service. You can typically find contact information on the product packaging, the official Halex website, or through your retailer.
Halex Official Website: Visit the Halex Store on Amazon
When contacting support, please have your product model number (HNF60R) and purchase details readily available.